• Title/Summary/Keyword: 교정치료진단

Search Result 343, Processing Time 0.019 seconds

Efficacy and Safety of Intraveous Iron Sucrose in the Perioperatively Anemic Patients of Gastrectomy (위 절제 수술 전후 빈혈 환자에 있어 철수크로오스의 유효성 및 안전성)

  • Yoo, Moon-Won;Cho, Jae-Jin;Lee, In-Kyu;Ahn, Hye-Seong;Jeong, Sang-Ho;Lee, Hyuk-Joon;Kim, Hyung-Ho;Lee, Kuhn-Uk;Yang, Han-Kwang
    • Journal of Gastric Cancer
    • /
    • v.8 no.1
    • /
    • pp.35-39
    • /
    • 2008
  • Purpose: This study was aimed to evaluate the efficacy and safety of of intravenous iron sucrose ($Venoferrum^{(R)}$) for treating the perioperative anemic gastrectomy patients. Materials and Methods: From September 2006 to February 2007 at Seoul National University Hospital, the gastrectomy patients who displayed perioperative anemia (7.0 g/dl $\leq$ hemoglobin levels (Hb) < 11.0 g/dl) and who were admitted or visited the outpatient clinic of the Department of surgery, were divided into two groups. The preoperative (${\leq}\;2{\sim}3$ weeks before gastrectomy) or postoperative ($\geq$ 1 month after gastrectomy) patients without evidence of acute bleeding were included into Group 1. The immediate postoperative (< 1 month after gastrectomy) patients with stable vital signs were included into Group 2. The age, gender, diagnosis, Hb, hematocrit (Hct), mean corpuscular volume (MCV), serum ferritin (SF), total iron binding capacity (TIBC), serum iron and reticulocyte counts (RC) were evaluated before and after intravenous iron sucrose administration. The adverse effects of drugs were investigated. Results: The number of patients of group 1 and group 2 was 79 and 46, respectively. In group 1, there was a statistically significant difference in the Hb, Hct, MCV, SF, RC and TIBC with each mean change of 1.3 g/dl, 4.1%, 3.1ft, 195 ng/ml, 0.2% and -86.4 ug/dl, respectively. In group 2, there was a statistically significant difference in the Hb, Hct, MCV, SF and RC with each mean change of 1.8 g/dl, 6.1%, 3.4fl, 260 ng/ml and 0.3%, respectively. Two patients (1.6%) suffered local thrombophlebitis as an adverse effect. Conclusion: Intravenous iron sucrose for the perioperative anemia of gastrectomy patients was efficacious in the short period without significant adverse effects.

  • PDF

COMPARISON OF THE CHRONOLOGY OF ROOT RESORPTION OF DECIDUOUS TEETH BETWEEN EARLY 1990S AND EARLY 2000S (1990년대 초와 2000년대 초의 유치 치근 흡수의 연령 비교)

  • Lee, Keun-Hye;Nam, Dong-Woo;Kim, Hyun-Jung;Nam, Soon-Hyeun;Kim, Young-Jin
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.362-371
    • /
    • 2004
  • It is essential to have adequate knowledge of the timing of root resorption of deciduous teeth for diagnosis and treatment planning in pediatric and orthodontic dentistry. Dental development is also influenced by hereditary characteristics, environmental factors, race, sex, endocrine reaction, nutrition, socioeconomic condition and secular factor. The aims of the present study were to determine the mean age of root resorption of deciduous teeth in contemporary Korean children and to compare the mean age of root resorption time of deciduous teeth between early 1990s and early 2000s. The study population was made up of Korean children attending the pediatric dentistry ward of Kyungpook National University Hospital. One thousand thirty seven children's panoramic radiograph (girls: 528 persons, boys: 509 persons) in $1990{\sim}1992$ and one thousand sixty five children's panoramic radiograph (girls: 394 persons, boys: 671 persons) in $2001{\sim}2003$ were examined. This study utilized a cross-sectional design. Due to the problems of imaging in the maxillary region and the mandibular incisor region, the mandibular deciduous canine, the mandibular deciduous first molar and the mandibular deciduous second molar were chosen for examination. The results were as follows. 1. There is a tendency for the teeth to resort earlier in the early 2000s group than the in early 1990s group. At the Res c stage, the difference of the mean age was 0.4 years. 2. At the Res c stage, the order of difference of the mean age from smaller to larger for the girls was the mandibular deciduous canine, the mandibular first deciduous molar, and the mandibular second deciduous molar. On the other hand, for the boys, the order was the mandibular second deciduous molar, the mandibular first deciduous molar, and the mandibular deciduous canine. The difference was larger with aging in girls and smaller with aging in boys. 3. There is a tendency for the teeth to resort earlier in girls in both the early 1990s group and the early 2000s group. The difference of the mean age between girls and boys was 0.3 year. 4. The commencement of root resorption of the mandibular deciduous canine was slower than that of the mandibular first deciduous molar. However, the completion of root resorption of the mandibular deciduous canine is faster than that of the mandibular first deciduous molar. The total elapsed time of root resorption from commencement to completion was shortest in the mandibular deciduous canine. 5. For each of the teeth in the early 1990s and the early 2000s groups, the speed of root resorption was in the later stage faster than in the earlier stage. In order to know about the exact timing of root resorption of deciduous teeth, periodic and longitudinal studies preferably covering the entire period of growth, is required.

  • PDF

Variation on Estimated Values of Radioactivity Concentration According to the Change of the Acquisition Time of SPECT/CT (SPECT/CT의 획득시간 증감에 따른 방사능농도 추정치의 변화)

  • Kim, Ji-Hyeon;Lee, Jooyoung;Son, Hyeon-Soo;Park, Hoon-Hee
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.25 no.2
    • /
    • pp.15-24
    • /
    • 2021
  • Purpose SPECT/CT was noted for its excellent correction method and qualitative functions based on fusion images in the early stages of dissemination, and interest in and utilization of quantitative functions has been increasing with the recent introduction of companion diagnostic therapy(Theranostics). Unlike PET/CT, various conditions like the type of collimator and detector rotation are a challenging factor for image acquisition and reconstruction methods at absolute quantification of SPECT/CT. Therefore, in this study, We want to find out the effect on the radioactivity concentration estimate by the increase or decrease of the total acquisition time according to the number of projections and the acquisition time per projection among SPECT/CT imaging conditions. Materials and Methods After filling the 9,293 ml cylindrical phantom with sterile water and diluting 99mTc 91.76 MBq, the standard image was taken with a total acquisition time of 600 sec (10 sec/frame × 120 frames, matrix size 128 × 128) and also volume sensitivity and the calibration factor was verified. Based on the standard image, the comparative images were obtained by increasing or decreasing the total acquisition time. namely 60 (-90%), 150 (-75%), 300 (-50%), 450 (-25%), 900 (+50%), and 1200 (+100%) sec. For each image detail, the acquisition time(sec/frame) per projection was set to 1.0, 2.5, 5.0, 7.5, 15.0 and 20.0 sec (fixed number of projections: 120 frame) and the number of projection images was set to 12, 30, 60, 90, 180 and 240 frames(fixed time per projection:10 sec). Based on the coefficients measured through the volume of interest in each acquired image, the percentage of variation about the contrast to noise ratio (CNR) was determined as a qualitative assessment, and the quantitative assessment was conducted through the percentage of variation of the radioactivity concentration estimate. At this time, the relationship between the radioactivity concentration estimate (cps/ml) and the actual radioactivity concentration (Bq/ml) was compared and analyzed using the recovery coefficient (RC_Recovery Coefficients) as an indicator. Results The results [CNR, radioactivity Concentration, RC] by the change in the number of projections for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.5%, +3.90%, 1.04] at -90%, [-77.9%, +2.71%, 1.03] at -75%, [-55.6%, +1.85%, 1.02] at -50%, [-33.6%, +1.37%, 1.01] at -25%, [-33.7%, +0.71%, 1.01] at +50%, [+93.2%, +0.32%, 1.00] at +100%. and also The results [CNR, radioactivity Concentration, RC] by the acquisition time change for each increase or decrease rate (-90%, -75%, -50%, -25%, +50%, +100%) of total acquisition time are as follows. [-89.3%, -3.55%, 0.96] at - 90%, [-73.4%, -0.17%, 1.00] at -75%, [-49.6%, -0.34%, 1.00] at -50%, [-24.9%, 0.03%, 1.00] at -25%, [+49.3%, -0.04%, 1.00] at +50%, [+99.0%, +0.11%, 1.00] at +100%. Conclusion In SPECT/CT, the total coefficient obtained according to the increase or decrease of the total acquisition time and the resulting image quality (CNR) showed a pattern that changed proportionally. On the other hand, quantitative evaluations through absolute quantification showed a change of less than 5% (-3.55 to +3.90%) under all experimental conditions, maintaining quantitative accuracy (RC 0.96 to 1.04). Considering the reduction of the total acquisition time rather than the increasing of the image acquiring time, The reduction in total acquisition time is applicable to quantitative analysis without significant loss and is judged to be clinically effective. This study shows that when increasing or decreasing of total acquisition time, changes in acquisition time per projection have fewer fluctuations that occur in qualitative and quantitative condition changes than the change in the number of projections under the same scanning time conditions.