• Title/Summary/Keyword: 교류 임피던스법

Search Result 51, Processing Time 0.062 seconds

Implementation of Multiple Frequency Bioelectrical Impedance Analysis System for Body Composition Analysis (신체 성분 분석을 위한 다 주파수 생체전기 임피던스 분석 시스템 구현)

  • Kim, Seong-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.11
    • /
    • pp.5403-5408
    • /
    • 2012
  • In this paper, we introduce the multiple frequency bio-electrical impedance analysis method for body composition analysis. And then we implement the multiple frequency bio-electrical impedance analysis system. Overall system consists of: multiple frequency alternating current signal generator contained alternating current signal, phase signal detector, voltage signal detector, micro controller, in-out device(key-pad LCD), conductivity electrodes, system power. We explain the architecture of the system and required theory to implement the system. In order to investigate the clinical significance of the body composition data, compare to the data measured by the expert body composition analyzer which provide high reproduction and precision. Finally, experimental results which are the correlation between the measured data show the very high reproduction performance of the body composition analysis in the proposed system.

EIS monitoring on corroded reinforcing steel in cement mortar after calcium electro-deposition treatment (칼슘 전착처리 후, 시멘트 모르타르 속 철근의 부식속도에 대한 EIS 모니터링)

  • Kim, Je-Kyoung;Kee, Seong-Hoon;Yee, Jurng-Jae
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.1-8
    • /
    • 2019
  • The primary purposes of this study are to understand a fundamental effects of electro-deposition on reinforcing steel in saturated Ca(OH)2 electrolyte, and evaluate the corrosion rates of rebars under cyclic 3wt.%NaCl immersion and dry corrosion environment. The three cement mortar specimens with cover thickness 5, 10 and 30mm, were prepared in the experiment. To monitor the corrosion rates of rebars in mortar, the three cement mortar specimens were exposed to 110 wet-drying cycles(8-hour-immersion in 3wt.%NaCl and 16-hour-drying in a room temperature) in the laboratory. During the wet-dry cycles, the polarization resistance, Rp, and solution resistance, Rs, were continuously measured. The instantaneous corrosion rates of rebars on the effect of electro-depositing with sat. Ca(OH)2 electrolyte were estimated from obtained R-1p and degrees of wetness were estimated from Rs values. From the experimental results, the corrosion rates of rebars were greatly accelerated by wet/dry cycles. During the mortars exposed to drying condition, the large increases in the corrosion rates were showed at all rebar surfaces in three mortar specimen, attributed from the accelerated reduction rates of dissolved oxygen in drying process. However, the corrosion rates on rebar surface electrochemically deposited with sat. Ca(OH)2 electrolyte showed the clear decreases, caused by calcium deposits in the porous rust layer.

Input LC Fiter Design of Diode Rectifiers Considering Filter VA Rating Reduction (필터소자의 용량 저감을 고려한 다이오드 정류기의 입력LC필터 설계)

  • 임영철;정영국
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.1
    • /
    • pp.35-44
    • /
    • 1998
  • In this paper, input LC filter design of diode rectifiers considering filter V A rating reduction has been propoesd. It consisted of an input LC parallel resonent tank whose inductor and capacitor values are se$.$ lected so that the input filter presents an infinite impedance to harmonic input ac current component. The operation of proposed input filter has been analyzed in detail under steady state conditions. Performance evaluation and related design data have been provided on Per Unit basis for the proper implementation of diode rectification system. Finally, Detailed input and output current analysis has shown that the proposed input filter yield high quality input ac current waveforms, in particular, high input power factor values and more reliabilty which reducing the V A rating of passive components as compared to the standard type LC filter.filter.

  • PDF

Dependence of Magneto-Impedence on Magnetizing Angle from Amorphous $Co_{66}Fe_4NiB_{14}Si_{15}$ Ribbon Axis (자화방향에 따른 비정질 $Co_{66}Fe_4NiB_{14}Si_{15}$ 리본의 자기임피던스 효과)

  • 유권상;김철기;윤석수;양재석;손대락
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.3
    • /
    • pp.134-139
    • /
    • 1997
  • Magneto-impedence (MI) were measured in amorphous $Co_{66}Fe_4NiB_{14} Si_{15}$ ribbons at 100 kHz as a function of the angle from ribbon axis. The samples were prepared using etching method, with the angle deviated from ribbon axis, 0$^{\circ}$, 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$ and 90$^{\circ}$. The MI measured in 60$^{\circ}$ sample increased with the increasing magnetic fields. The dip in profile appears at H = 0 above the angle of 30$^{\circ}$. The maximum values of MI and their dips are increased with the cutting angle, but the maximum value of MI decreased at 90$^{\circ}$. The increase of MI with the angle was analyzed in terms of the transverse magnetic permeability.

  • PDF

Effect of Total Resistance of Electrochemical Cell on Electrochemical Impedance of Reinforced Concrete Using a Three-Electrode System (3전극방식을 활용한 철근 콘크리트의 교류임피던스 측정 시 전기화학 셀저항의 영향)

  • Khan, Md. Al-Masrur;Kim, Je-Kyoung;Yee, Jurng-Jae;Kee, Seong-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.6
    • /
    • pp.82-92
    • /
    • 2022
  • This study aims to investigate the effect of total electrochemical cell resistance (TECR) on electrochemical impedance (EI) measurements of reinforced concrete (RC) by electrochemical impedance spectroscopy (EIS) using a three-electrode system. A series of experimental study is performed to measure electrochemical behavior of a steel bar embedded in a concrete cube specimen, with a side length of 200 mm, in various experimental conditions. Main variables include concrete dry conditions, coupling resistance between sensing electrodes and concrete surface, and area of the counter electrode. It is demonstrated that EI values remains stable when the compliant voltage of a measuring device is sufficiently great compared to the potential drop caused by TECR of concrete specimens. It is confirmed that the effect of the coupling resistance of TECR is far more influential than other two factors (concrete dry conditions and area of the counter electrode). The results in this study can be used as a fundamental basis for development of a surface-mount sensor for corrosion monitoring of reinforced concrete structures exposed to wet-and-dry cycles under marine environment.

Studies on the Conducion path and Conduction Mechanism in undeped polycrystalline Diamond Film (도핑되지 않은 다이아몬드 박막의 전기전도 경로와 전도기구 연구)

  • Lee, Bum-Joo;Ahn, Byung-Tae;Lee, Jae-Kab;Baek, Young-Joon
    • Korean Journal of Materials Research
    • /
    • v.10 no.9
    • /
    • pp.593-600
    • /
    • 2000
  • This paper investigated the conduction path and conduction mechanism in undoped polycrystalline diamond thin films deposited by microwave chemical vapor deposition. The resistances measured by ac impedance spectroscopy with different directions can not be explained by the previously-known surface conduction model. The electrodeposition of Cu and electroetching of Ag experiments showed that the conduction path is the grain boundaries within the diamond films. The electodeposition of Cu with an insulating surface layer further proved that the main conduction path in polycrystalline films in the grain boundaries. The film with high electrical conductivity has low activation energy of 45meV and higher dangling bond density. By considering the results and surface C chemical bonds, the H-C-C-H bonds at surface and in grain boundaries might be the origin of high conductivity in undoped diamond films.

  • PDF

P(VDF-HPF)-Based Polymer Electrolyte Filled with Mesoporous ZnS (메조포러스 ZnS가 충전된 P(VDF-HPF) 고분자 전해질)

  • Seo, Young-ju;Cha, Jong-Ho;Lee, Huen;Ha, Yong-Joon;Koh, Jeong Hwan;Lee, Chulhaeng
    • Korean Chemical Engineering Research
    • /
    • v.46 no.1
    • /
    • pp.170-174
    • /
    • 2008
  • ZnS-polymer gel films were prepared with incorporating mesoporous ZnS synthesized by surfactant-assisted templating process and poly (vinylidene fluoride)-hexafluoropropylene copolymer (P(VDF-HFP)) in order to observe the variation of ionic conductivities according to the various weight ratios between ZnS and P(VDF-HFP). Ionic conductivities for each gel electrolyte were measured with increasing temperature. As a result, ionic conductivities increased with increasing the amount of ZnS and temperature. In particular, the films with 20 and 25 wt% ZnS were found that they possessed the high ionic conductivity of approximately $10^{-4}Scm^{-1}$ at room temperature. However, above 20 wt% of ZnS, the enhancement of ionic conductivity was not observed. For the characterization of ZnS and the gel electrolyte, XRD (x-ray diffractometer), DSC (differential scanning calorimetry), TGA (thermogravimetric analysis), FT-IR (fourier transform-infrared spectrometer), SEM (scanning electron microscopy) and TEM (transmission electron microscopy) were employed. Ionic conductivities were measured by a.c. impedance method.

Anti-Corrosion Behaviour of Rebar in Cement Mortar by Electrochemical Chloride Extraction (전기화학적 염소 추출법에 의한 시멘트 모르터내의 철근 방식)

  • Nam Sang Cheol;Lim Young Chang;Cho Won-Il;Cho Byung Won;Chun Hai Soo;Yun Kyung Suk
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.1
    • /
    • pp.31-38
    • /
    • 2000
  • Anti-corrosion behaviour of rebar embedded in cement mortar containing chloride ions was investigated by electrochemical chloride extraction(ECE). $43\%$ of the initial chloride ions of the cement mortar was fixed to Friedel salts and the soluble chloride ions were successfully extracted by ECE method. Concentration profiles of the chloride ions were estimated by Fick's 2nd law with time and depth, and it was close to the real value. The corrosion potential increased to anodic direction after ECE test, and the corrosion of rebar was reduced as a result of AC impedance spectroscopy.

Electrochemical Characteristics of Electrolyte Membrane for Hydrogen Production in High Temperature Electrolysis (고온 수증기 전해 수소제조를 위한 전해질 막의 전기화학적 특성 고찰)

  • Choi Ho-Sang;Son Hyo-Seok;Sim Kyu-Sung;Hwang Gab-Jin
    • Membrane Journal
    • /
    • v.15 no.4
    • /
    • pp.349-354
    • /
    • 2005
  • YSZ (yttria-stabilized zirconia) determined with an electrolyte that analyzed thermal stability along sintering condition and an electric characteristic. As sintering temperature increases by SEM, grain grows and it showed that pore decreases relatively. and confirmed effect by grain size. It evaluated that particle internal resistance and electric performance by resistance in an electrolyte and electricity conductivity measurement through ac impedance measurement in temperature of $800\~1000^{\circ}C$ in 2-probe method In order to recognize an electric characteristic. In dry process and wet process, density was each 6.13, 6.25 $g/cm^3$ and the relative density was each 98, 99$\%$ when sintering condition is $1400^{\circ}C$.

Geophysical Logging of Frequency-domain Induced Polarization for Mineral Exploration (광물탐사를 위한 진동수영역 유도분극 물리검층)

  • Shin, Seungwook
    • Geophysics and Geophysical Exploration
    • /
    • v.24 no.3
    • /
    • pp.73-77
    • /
    • 2021
  • Induced polarization (IP) is useful for mineral exploration and hydrogeological studies by visualizing the electrochemical reactions at the interface between polarized minerals and groundwater. Frequency-domain IP (FDIP) is not actively applied to field surveys because it takes longer to acquire data, despite its higher data quality than conventional time-domain IP. However, data quality is more important in current mineral exploration as the targets gradually shift to deep or low-grade ore bodies. In addition, the measurement time reduced by automated instrumentation increases the potential for FDIP field applications. Therefore, we demonstrate that FDIP can detect mineral exploration targets by performing geophysical logging in the boreholes of a skarn deposit, in South Korea. Alternating current (AC) resistivity, percent frequency effect (PFE) and metal factor (MF) were calculated from impedance values obtained at two different frequencies. Skarn zones containing magnetite or pyrite showed relatively low AC resistivity, high PFE, and high MF compared to other zones. Therefore, FDIP surveys are considered to be useful for mineral exploration.