• Title/Summary/Keyword: 교류손실

Search Result 221, Processing Time 0.032 seconds

A Study on AC Loss of Ag Sheathed Bi-2223 Superconducting Tapes (Bi계 초전도 테이프의 교류손실 연구)

  • Jeong, Jong-Man;Jang, Hyeon-Man;Sin, Jae-Hwa;Choe, Jae-Seok;Kim, Sang-Hyeon
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.48 no.1
    • /
    • pp.29-33
    • /
    • 1999
  • Superconducting tape is being developed for electrical equipment such as superconducting transformers and generators etc. AC loss reduction is primary concerned in the development of such high-efficiency equipment. AC losses in Bi-2223 silver-sheathed tapes, both single and multi-filamentary, were investigated by means of AC magnetization techniques when longitudinal fields are applied. The experiment resultswere compared with the hysteresis loss equation based on Bean model and the eddy current loss equation. The AC loss of the mono-filamentary tape was dominated by the hysteresis. On the contrary, the AC loss of the multi-filamentary tape was substantially dominated by the eddy current loss in the silver matrix.

  • PDF

The effect of twisting on microstructure and AC losses of Bi-2223 superconductor tapes (Twisting된 Bi-2223 선재의 미세조직 관찰 및 교류손실 특성평가)

  • 장석헌;임준형;김정호;김규태;주진호;나완수;정재훈;류경우
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.126-128
    • /
    • 2003
  • The effect of twisting on the microstructure and AC losses of Bi-2223 superconductor tape has been evaluated. Twisting pitches of the tapes are in the range of 12~60 mm and uniformly deformed. The critical current of the tapes was measured to decreased with decreased pitch. This reduction is believed to be due to the irregular interface, poor grain alignment. In addition, AC losses of the tape reduced as the pitch decreased probably due to combined effects of lower critical current and electrically decoupled filament of twisted tape.

  • PDF

Influence of Current Distributions on AC Loss Characteristics in a 3-conductor (전류분포가 3본-도체의 교류손실 특성에 미치는 영향)

  • 정재훈;류경우
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.206-209
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The ac loss characteristics in the conductor have experimentally investigated. The loss tests indicate that the ac loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

Influence of Current Distributions on AC Loss Characteristics in a 3-conductor (전류분포가 3본-도체의 교류손실 특성에 미치는 영향)

  • 정재훈;류경우
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.7-10
    • /
    • 2003
  • AC loss is an important issue in the design of high-T$_{c}$ superconducting power cables which consist of a number of Bi-2223 tapes wound on a former. In the cables, the tapes have different critical currents intrinsically. And they are electrically connected to each other and current leads. These make loss measurements considerably complex, especially for short samples of laboratory size. So special cautions are required in the positioning of voltage leads for measuring the true loss voltage. In this work we have prepared a conductor composed of three Bi-2223 tapes with different critical currents. The ac loss characteristics in the conductor have experimentally investigated. The loss tests indicate that the ac loss is dependent on arrangements of voltage leads but not on their contact positions. The measured losses in the conductor also agree well with the sum of the transport losses measured in each Bi-2223 tape.e.

  • PDF

Current Sharing and AC Loss of a Multi-Layer HTS Power Transmission Cable with Variable Cable Length (다층 고온초전도 송전케이블의 길이에 따른 층별 전류분류 및 교류손실 계산)

  • Lee, Ji-Kwang;Cha, Guee-Soo
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.1
    • /
    • pp.10-14
    • /
    • 2001
  • The superconducting transmission cable is one of interesting part in power application using high temperature superconducting wire. One important parameter in HTS cable design is transport current sharing because it is related with current transmission capacity and loss. In this paper, we calculate self inductances of each layer and mutual inductances between two layers from magnetic field energy, and current sharing of each layer for 4-layer cable using the electric circuit model which contain inductance and resistance (by joint and AC loss). Also, transport current losses which are calculated by monoblock model and Norris equation are compared. As a results, outer layer has always larger transport current than inner layer, and current capacity of each layer is largely influenced by resistance per unit cable length. As a conclusion, for high current uniformity and low AC loss, we have to decrease inductances themselves or those differences.

  • PDF

AC Loss of the Double Pancake Winding by External Field (외부자계 인가시 더블팬케이크 권선에서 발생하는 교류손실)

  • Lee, Hee-Joon;Lee, Seung-Wook;Cha, Guee-Soo;Lee, Ji-Kwang
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.99-101
    • /
    • 2001
  • Magnetization loss which is generated in HTS wire varies with the direction of the external magnetic field. This paper calculates the magnetization loss in an HTS transformer winding, where effects of the direction of magnetic field are considered. Kim model is used to consider the variation of the critical current with magnetic field and Brandt equation is used to calculate the loss by perpendicular magnetic field in transformer winding. Magnetization loss in an HTS transformer can be calculated more precisely with this paper.

  • PDF

Critical Current and AC loss Characteristics of mini-model HTS cable (고온 초전도 모델 케이블의 임계전류 및 교류손실 특성)

  • Kim, Hae-Joon;Sim, Ki-Deok;Kim, Jae-Ho;Cho, Jeon-Wook
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.809-810
    • /
    • 2006
  • Reduction of AC losses is very important for realizing HTS cable and it had been reported that the same layer current controlled by twisting pitch and direction could reduce the AC losses effectively. During the long-term development of HTS cables, the superconductor AC losses will need to be reduced to a level determined by the economics of each installation and the efficiency of the refrigeration. Theoretical models have been developed to predict the magnitude of the losses in cables composed of several layers of flat HTS tapes. This paper is manufactured mini-model HTS cable and voltage signal line to spiral shape. Mini-model HTS cable is composed of 13 HTS tape. We measured to critical current and AC loss and compared used lock-in-amp to cancel coil. This data is useful to HTS cable of DAPAS program.

  • PDF

전력변환 시스템의 현상과 동향

  • 양승학;장영학
    • 전기의세계
    • /
    • v.45 no.7
    • /
    • pp.39-44
    • /
    • 1996
  • 전력변환 시스템의 고성능화를 위해서는 스윗칭 주파수를 고주파수로 하는 것이 필요하다. 그러나 PWM방식에서는 반도체 소자를 강제적으로 스윗칭시키기 때문에 고주파 스윗칭을 행하면 EMI, EMC 문제를 무시할 수 없게 되고 스윗칭 손실은 스윗칭 주파수와 함께 증가한다. 이 문제를 해결하기 위해 1986년에 미국 위스콘신대학에서 당초 인공위성 등에 탑재하는 직류전원으로서 직류/직류 컨버터의 공진 스위치였던 회로구성을 3상 직류링크 전압형 인버터에 전개하여 소프트 스윗칭이 가능하게 되는 교류전원용의 전압형 인버터를 발표하였다. 또한 그 당시에 또 다른 공진형 회로구성인 교류링크 인버터도 발표되었다[3-5]. 이러한 배경으로 이하에서는 PWM 전력변환기의 소개를 시작으로 고주파수화의 필요성 및 그로 인해 파생되는 문제점을 고찰하고, 공진형 전력변환 시스템의 필요성에 대하여 논한 뒤 각종의 공진형 변환기에 대하여 간략하게 설명하고자 한다.

  • PDF

Round-robin Test on AC Losses in a Technical High-Tc Superconducting Tape (실용고온초전도테이프의 교류손실에 대한 Round-robin테스트)

  • 류경우;최병주;황시돌
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.53 no.7
    • /
    • pp.437-443
    • /
    • 2004
  • In this work the AC loss measurement setup based on an iron core background magnet, not used in a conventional one, has been successfully developed. To prove its validity, a round-robin test for the same Bi-2223 tape sample among three institutes has been done. The results show that the self-field and magnetization losses from the developed setup well agree with the losses measured at two other institutes of Korea Basic Science Institute and Yokohama National University. The measured magnetization losses for parallel or perpendicular fields can be well predicted from the slab model or the strip model for a filamentary region. However the magnetization losses for longitudinal fields can be rather predicted by the slab model for a decoupled filament. The self-field losses are well explained by the Norris ellipse model.

Frequency dependence of AC loss in YBCO Bulk superconductor (YBCO Bulk 초전도체 교류손실의 주파수 의존성)

  • Ye, Jung-Hee;Nah, Wan-Soo;Kim, Chan-Jong;Hong, Gye-Won
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.259-261
    • /
    • 1999
  • In this paper, we investigated the frequency dependences of AC loss and the magnetic properties of a superconductor using magnetization method. We used the YBCO bulk superconductor sample which has a square-shaped cross sectional area of $6mm{\times}6mm$. and 43mm-long in axial direction. The applied AC magnetic field was parallel to the direction of sample axis. It is observed that YBCO bulk has the diamagnetic properties. AC loss calculation of YBCO bulk superconductor was performed by evaluating the total area of magnetization traces. We performed two cases of experiments, one for $B_m<B_p$ and the other for $B_m<B_p$. The experiments showed that the AC loss dependences on frequency were different in each mode, as was indicated in other publications.

  • PDF