• Title/Summary/Keyword: 교량형태

Search Result 245, Processing Time 0.021 seconds

A Study of the Local Scour Considering the Pier Shapes in the Cohesive Bed (점착성 하상에서의 교각형상에 따른 국부세굴 연구)

  • Choe, Gye-Un;Kim, Gi-Hyeong
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.5
    • /
    • pp.539-552
    • /
    • 1998
  • When the pier is constructed in the cohesive be, the accuracy maynot be obtained because the equation for calculating the scour at piers is based upon the results which are analyzed through the experiments in the non-cohesive bed. In this paper, the variation of the depth of the pier scour occurred by constructing 5 types of pier in the channel having the cohesive material is examined. The experimental results are analyzed based upon Froude numbers and non-dimensional numbers which are indicated as the flow depths compared to the pier width. The results are also compared with the results obtained using the existing pier scour equations. In this paper, the shape factors, which can be used for calculating the scour depth of the pier in the cohesive channel bed, are suggested. The shape factors are indicated through the ratios between the scour depth at the circular pier and the scour depths at the different types of pier, and are suggested as two stages. In the first stage, in which the water depth compared to the pier width is less than 1.2, the shape factors are given as the equations. However, in the second stage the shape factors are given as the constant values. It is understood that the shape factors suggested in this paper can be properly usd for calculating local scour at piers in the bridges which are constructed in the cohesive channel bed having the characteristics of the bed material which is used in these experiments. Keywords : local scour, maximum scour depth, cohesive bed material, pier shape, pier, shape factor.

  • PDF

Processing of Various RFID Reader Devices for ALE Middleware (ALE 미들웨어를 위한 다양한 RFID 리더 처리 방법)

  • Noh, Young-Sik;Byun, Yung-Cheol;Lee, Dong-Cheol
    • The Journal of the Korea Contents Association
    • /
    • v.9 no.4
    • /
    • pp.55-64
    • /
    • 2009
  • For realizing ubiquitous computing, many research activities are geared towards various areas including embedded computing, RFID, USN, home networking, context-awareness, and etc. By using the ability of RFID technology to recognize a number of objects simultaneously, more convenient ubiquitous application services are effectively provided. In this case, RFID middleware playing a role as a bridge between RFID reader devices and application services is required as well. In this paper, we propose a method of handling a number of types of RFID reader devices in ALE middleware of EPCglobal. For this, the information of connection and data protocol for a reader device is stored in a database as ontology meta-data, and used to interpret the data read by a reader device. By adding ontology data into a database, even though an RFID device newly emerges, ALE middleware can not only handle the device, but also be effectively extended through reusing ontology data, without any changes in the middleware.

Damage Evaluation for the Column of Underpass Considering the Collision of a Vehicle (차량의 충돌을 고려한 지하차도 기둥의 손상 평가)

  • Park, Jang Ho;Kim, Young Woong;Park, Jaegyun
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.28 no.2
    • /
    • pp.169-176
    • /
    • 2015
  • The protection facilities against the collision of the vehicle should be considered in the design of the bridge by the regulations, but there is no regulation against the collision of the vehicle in the design of the column of underpass. Impact analysis for the column of underpass was performed in order to evaluate the damage of the structure by the collision of the vehicle. Impact analysis was performed according to the various parameters such as material properties of the structure and types and velocities of the vehicle. From the numerical results, the structural damage for the column of underpass by the collision of the vehicle was evaluated and considerations in the design for a column of underpass against the collision of the vehicle were examined.

Characteristics of the Stress-strain Relationship of Square Sectional Concrete Confined by Hoop Reinforcement with Cross-ties (후프띠철근과 보강띠철근으로 횡구속된 정사각단면 콘크리트의 응력-변형률 특성)

  • Jeong, Hyeok-Chang;Cha, Soo-Won;Kim, Ick-Hyun
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.39-48
    • /
    • 2010
  • Improved seismic performances of RC bridges can be attained by sufficient ductilities of piers, which can be obtained by providing sufficient lateral confinements to the plastic hinge regions of piers. The cross sectional shape and the amount of lateral reinforcements are key parameters in the determination of effective confinements. Even though identical amounts of lateral reinforcement are provided, the effective confinement differs due to different spacing, arrangements, hook details and so on. Unlike circular sections in which confinement is exerted by mere hoop reinforcements, cross-ties are arranged in square or rectangular sections to enhance the effective confinements. The stress-strain relationship of confined concrete is varied by how to consider these cross-ties. In this study, the stress-strain relationships of confined concrete with cross-ties are investigated experimentally and their mechanical characteristics are estimated by comparison with other empirical equations.

In-plane elastic buckling strength of parabolic arch ribs subjected symmetrical loading (대칭 하중을 받는 포물선 아치 리브의 탄성 면내 좌굴 강도)

  • Moon, Ji Ho;Yoon, Ki Yong;Kim, Sung Hoon;Lee, Hak Eun
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.2 s.75
    • /
    • pp.161-171
    • /
    • 2005
  • When the in-plane flexural rigidity is small in relation to the applied load, the arch ribs may buckle to the in-plane direction. Designers should therefore determine the in-plane buckling strength. To determine the buckling strength of arch ribs, designers have to consider the material nonlinear response. But in the case of arch ribs having large slenderness ratio, arch ribs may buckle in the elastic range, and when the arch ribs have low slenderness ratio, elastic buckling strength is useful in the preliminary design. In this paper, elastic buckling strength of arch ribs, which are frequently used in practical design, is studied using nonlinear finite element method. In general, the relation between flexural rigidity and elastic buckling strength is linear. As seen from the results, however, when the arch ribs have low slenderness ratio, the relation between flexural rigidity and elastic buckling strength is nonlinear.

Seismic Damage Index Proposal and Damage Assessment for Cable-Stayed Bridge (사장교의 내진 손상지수의 제안 및 손상도 평가)

  • Kim, Eung-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.127-135
    • /
    • 2018
  • With the nation showing increasing concern for earthquakes, there have been several methods for the analysis of earthquakes and evaluation of damage. Nevertheless, there is no clear standard to assess the seismic damage to structures quantitatively. Accordingly, this study conducted seismic analysis of several forms of seismic waves and actual seismic load, targeting the cable stayed bridge, which is supported by a cable and proposes a method for evaluating the damage based on the results. The damage index was calculated based on the tilting of the pylon of the cable-stayed bridge and the characteristics of physical seismic damage was suggested with 4 levels, such as A, B, C, and D. In addition, it is not proper to simply judge that the seismic damage index is obtained as large or small at all times depending on the seismic analysis method. Although this study focused on the proposal seismic damage index and an evaluation of the damage targeting the cable stayed bridge, the result was applied to a structure with a similar maximum displacement response.

An Experimental Study to Evaluate the Subsidence Stability of Riprap Protection without Filters (필터 없는 사석보호공의 유사이탈로 인한 침하 안정성 평가를 위한 실험 연구)

  • Ji, Un;Yeo, Woon-Kwang;Lee, Won-Min
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.4
    • /
    • pp.445-454
    • /
    • 2008
  • Many countermeasures for local scour at bridge piers constructed on the river and sea have been developed and researched to protect piers against local scour. The most commonly employed method is riprap protection, which is sometimes required the filter installation between riprap and base layers. However, the construction of stone filters are really hard to perform in the field, require the high cost, or sometimes are impossible. The experimental modeling is conducted to analyze the riprap failure modes and the stability of riprap protection without filters based on the different approach velocity and riprap layer thickness conditions. Also, the stability index to evaluate the performance of riprap protection is developed using the experimental results. The cover and thickness of the riprap layer play a very important role in the stability and thicker riprap layers can prevent a total disintegration of the riprap layer effectively, especially due to winnowing failure.

Behavior of Steel-Concrete Composite Decks for PSC Girder Bridge with Various Shear Span Lengths (전단 지간의 변화에 따른 PSC 거더용 강-콘크리트 합성 바닥판의 역학적 거동)

  • Kim, Tae-Hyup;Park, Jun-Myung;Hong, Sung-Nam;Park, Sun-Kyu;Kim, Hyeong-Yeol
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.3
    • /
    • pp.275-281
    • /
    • 2007
  • Recently, steel-concrete composite structures are widely used in bridge and building constructions. In this paper, a new type of steel-concrete composite deck with profiled steel sheeting is proposed to replace the conventional cast-in-place reinforced concrete deck. Perfobond rib shear connectors were utilized to provide horizontal shear resistance between the profiled sheeting and the concrete. To validate the effectiveness of the proposed deck system, 8 full-scale deck specimens for PSC girder bridge were fabricated. The specimens were tested with four different shear span lengths to determine the horizontal shear resistance of the deck under a static monotonic loading. For comparison purpose, two reinforced concrete decks were also fabricated and tested. The horizontal shear resistance of the proposed deck system was calculated using the m-k method.

Experimental Study on the Static Behavior of the Spliced PSC Box Girder (분절 PSC 박스거더의 정적거동에 관한 실험적 연구)

  • Chung, Won-Seok;Kim, Jae-Hueng;Chung, Dae-Ki
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.433-439
    • /
    • 2007
  • The main objective of the paper is to investigate the static behavior of a prestressed concrete (PSC) girder that has been spliced with precast box segments. A 20 m long full-scale spliced PSC girder is fabricated and tested to compare its static performance against a monolithic girder. The monolithic girder has the same geometric and material properties with respect to the spliced girder. This includes infernal strain, deflections, neutral axis position, and crack patterns for both girders. The test also consists of monitoring relative displacements occurring across the joints. Both the horizontal displacement (gap) and vertical displacement (sliding) are measured throughout the loading procedure. All results have been compared to those obtained from the monolithic girder. It has been demonstrated that the spliced girder offers close behavior with respect to the monolithic girder up to the crack load. Both girders exhibits ductile flexural failure rather than abrupt shear failure at joints.

A Study of the Advanced Composite Material Slab for Light Weight of Tall Building (초고층빌딩 경량화를 위한 복합신소재 슬래브에 관한 연구)

  • Han, Bong-Koo
    • Composites Research
    • /
    • v.27 no.1
    • /
    • pp.7-13
    • /
    • 2014
  • For each construction material used, there is certain theoretical limit in sizes. For tall building construction, the reduction in slab weight is the first step to take in order to break such size limits. In this paper, the feasibility of such objective is proven and given by numerical analysis result. For a typical building slab, both concrete and advanced composite sandwich panels are considered. The concrete slab is treated as a special orthotropic plate to obtain more accurate result. For each panel, the deflection under the dead and live loads is compared, since both tensile and compressive strengths of the composites are far more higher than those of concrete. All types of sandwich panels considered, except one case, have self-weights less than one tenth of that of the reinforced concrete slab, with deflections less than that of the reinforced concrete slab.