• Title/Summary/Keyword: 광 계수기

Search Result 170, Processing Time 0.032 seconds

Improvement of Bit Error Rate using the Optimal Parameters of Optical Phase Conjugator in WDM System with Non Zero - Dispersion Shifted Fiber (비영 분산 천이 광섬유를 갖는 WDM 시스템에서 광 위상 공액기의 최적 파라미터를 이용한 비트 에러율 개선)

  • Kim Eun-Mi;Lee Seong-Real
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2006.05a
    • /
    • pp.361-364
    • /
    • 2006
  • The numerical methods of finding the optimal position of optical phase conjugator (OPC) and the optimal fiber dispersions are proposed, which are able to effectively compensate overall channels in $8\times40$ Gbps WDM system with non zero - dispersion shifted fiber (NZ-DSF) as an optical fiber. And BER characteristics in the system with two induced optimal parameters are compared with those in the system with the currently used mid-span spectral inversion (MSSI) in order to confirm the availability of the proposed methods. It is confirmed that the applying two induced optimal parameters into WDM system contribute to reduce power penalty to 4 times than that of WDM system with the conventional MSSI.

  • PDF

Improvement of Bit Error Rate through the Optimization of 320 Gbps WDM System with Non Zero-Dispersion Shifted Fiber (비영 분산 천이 광섬유를 갖는 320 Gbps WDM 시스템에서 최적화를 통한 비트 에러율 개선)

  • Lee, Seong-Real;Yim, Hwang-Bin
    • Journal of Advanced Navigation Technology
    • /
    • v.10 no.2
    • /
    • pp.103-113
    • /
    • 2006
  • The numerical methods of finding the optimal position of optical phase conjugator (OPC) and the optimal fiber dispersions are proposed, which are able to effectively compensate overall channels in $8{\times}40$ Gbps WDM system with non zero-dispersion shifted fiber (NZ-DSF) as an optical fiber. And BER characteristics in the system with two induced optimal parameters are compared with those in the system with the currently used mid-span spectral inversion (MSSI) in order to confirm the availability of the proposed methods. It is confirmed that two optimal parameters depend on each other, but less related with the searching procedure. The methods proposed in this research will be expected to alternate with the method of making a symmetrical distribution of power and local dispersion in real optical link which is a serious problem but the condition in the case of applying the OPC into multi-channels WDM system.

  • PDF

Wideband WDM Transmission through the Power Symmetry Method in the Mid-Span Spectral Inversion (Mid-Span Spectral Inversion을 이용한 광 펄스 왜곡의 보상에서 전력 대칭을 통한 광대역 WDM 전송)

  • 이성렬;이윤현
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.12 no.7
    • /
    • pp.1157-1166
    • /
    • 2001
  • In this paper, we investigated the degree of compensation for optical pulse shape distortion due to both chromatic dispersion and SPM(self phase modulation) in high speed optical transmission system with dispersion shift fiber. We adopted the power symmetric MSSI(mid-span spectral inversion) as compensation method. We used EOP(eye-opening penalty) parameter in order to evaluate the compensation efficiency of distorted optical pulse. We evaluated input signal power range being able to maintain stable reception performance in the case of various chirp parameter of modulated optical pulse. And, in order to verify the applicable to wideband WDM system, we evaluated the wavelength range being able to maintain stable reception performance through the EOP calculation of various dispersion coefficient of first fiber D$\_$11/. We showed that proposed MSSI is effective compensation method to down chirped optical pulse transmission rather than up chirped optical pulse transmission in anomalous dispersion range. And we showed that this method have possibility of relative high power transmission and wideband transmission in WDM system.

  • PDF

Optical information storage using diffraction properties of volume hologram in Fe-LiNbO$_3$ crystal (Fe-LiNbO$_3$결정에서 부피형 홀로그램의 회절특성을 이용한 광정보 저장)

  • An, Jun-Won;Kim, Nam;Lee, Kwon-Yeon
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.6
    • /
    • pp.63-71
    • /
    • 1998
  • In this paper, we experiment the characteristics of coupling coefficient, gain, diffraction efficiency and dependence of time determined by TWM(Two-Wave Mixing), using Fe-LiNbO$_3$ crystal(doped with 0.015Wt.%). From these results, we proposed to apply for optical memory application. The highest coupling angle of 14。 and maximum coupling coefficient of 6.9$cm^{-1}$ / are obtained at 514.5nm wavelength. Also, maximum diffraction efficiency is 54.13% when intensity ratio and writing beam incident angle are 0.1 and 14o, respectively. After fixing process, diffraction efficiency is 21.4%. As an example, we demonstrated the writing and reconstruct optical data using spatial light modualtor and angular multiplexing in most optimal condition.

  • PDF

Induction of Optimal Condition of 40 Gbps RZ Format for OTDM/WDM Transmission (OTDM/WDM 전송을 위한 40 Gbps RZ 형식의 최적 조건 도출)

  • Lee, Seong-Real
    • Journal of Advanced Navigation Technology
    • /
    • v.14 no.6
    • /
    • pp.831-837
    • /
    • 2010
  • Optimal conditions of 40 Gbps RZ format for implementation of optical time division multiplexing/wavelength division multiplexing (OTDM/WDM) transmission system are induced by analyzing and comparing performance depending on duty cycle and extinction ratio (ER). Optical phase conjugator (OPC) and inline dispersion management (DM) are applied into optical transmission links for compensating signal distortion due to chromatic dispersion and nonlinearity of fiber. It is confirmed that RZ format of 0.25 duty cycle is less effected by system performance change depending on ER and it is suitable for multiplexing to 160 Gbps signal through OTDM. Also, it is shown that performance improvement of RZ format determined by same net residual dispersion (NRD) is more increased as residual dispersion per span (RDPS) becomes large.

A study on the development of oxygen measurement device for diagnosis of peripheral vascular disease in lower extremity (하지 (下脂) 조직내의 말초 혈관계 질환 진단을 위한 산소 측정장치의 개발에 관한 연구)

  • 임현수;이준규;박동철
    • Progress in Medical Physics
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 1999
  • The oxygen saturation of blood can be measured by the difference absorption in optical spectra of Hb and Hb0$_2$, as the well known previous study. In this study we developed the non-invasive oxygen measurement device for diagnosis of peripheral vascular disease in lower extremity using infrared and red LED which produce a peak spectral emission at a wavelength of 660 nm, and 940 nm. To evaluate the clinical application of the oxygen measurement device, we performed lower extremity study to measure the oxygen changes in response to physiological changes within biological tissue. The results showed that oxygen saturation of blood in biological tissue can be monitored from the separation arrangement light source and detector.

  • PDF

A Study on the Development of Quantitative Analysis Methods to Characterize the Transport of Microplastics in Saturated Porous Media (포화 다공성 매체에서 미세플라스틱 이동 특성 규명을 위한 정량분석 방법 개발 연구)

  • Suhyeon Park;Minjune Yang
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.376-376
    • /
    • 2023
  • 전 세계적으로 중요한 담수 자원인 지하수의 미세플라스틱 오염에 대한 우려가 커지고 있다. 지하수 환경에서 미세플라스틱의 오염을 예측하고 평가하기 위해 대수층 내 현장 실태조사가 수행 중에 있으며, 실험실 규모의 컬럼 실험을 통해 지하수에서 미세플라스틱 이동 메커니즘을 조사하는 연구들이 수행되고 있다. 이러한 연구들은 많은 개수의 분석 시료를 동반하며, 환경 중 미세플라스틱 정량분석을 위해서 고가의 분석기기(라만분광기, 푸리에 변환 적외선(FTIR) 분광기, 열분해 가스크로마토그래피 질량분석기)를 사용하여 플라스틱의 종류를 판별하고 개수를 측정하고 있다. 또한, 컬럼 실험을 수행한 대부분의 선행 연구에서는 미세플라스틱 정량분석을 위해 탁도 분석, 분광광도계를 이용한 흡광도 분석, 현미경을 이용한 계수 방법 등을 이용하여 고가의 분석기기를 사용하지 않고 연구를 수행하였다. 하지만, 이러한 방법들은 유체 속 다른 물질이 포함되어있을 경우에 민감하고 농도를 비율 혹은 개수로 표현하기 때문에 질량 측면에서 미세플라스틱의 농도를 과소·과대 평가할 수 있다. 특히, 현미경을 이용한 계수 방법의 경우에는 분석에 많은 시간이 소요된다는 단점이 있다. 위에 언급한 다양한 분석법들의 단점들을 보완하기 위하여, 본 연구에서는 대수층 내 미세플라스틱 이동 특성을 규명하기 위한 실내 실험에 사용될 수 있는 형광이미지 기반의 미세플라스틱 정량분석법을 개발하였다. Nile Red 형광염료를 이용하여 미세플라스틱을 염색하고 사진을 촬영하여 미세플라스틱 시료의 질량과 미세플라스틱 형광이미지의 형광강도 간 상관관계를 분석하였다. 또한, Nile Red로 염색된 미세플라스틱 입자의 수중 노출 테스트를 진행하여, 실내 대수층 모의실험 시 미세플라스틱 질량을 정량화할 수 있는 적용 가능성을 평가하였다. 상관 분석 결과, 미세플라스틱 질량과 이미지의 형광강도는 높은 상관관계를 보였으며, 수중 노출 실험 전과 후의 미세플라스틱 입자의 형광강도 차이는 미미한 것으로 나타났다. 이러한 연구결과를 통해 본 연구에서 개발된 미세플라스틱 정량분석 방법이 포화 다공성 매체로 구성된 컬럼실험 시 유출수의 미세플라스틱 질량 추정에 유용하게 사용될 것으로 생각되며, 대수층 내 미세플라스틱의 이동 특성 규명 연구에 많은 도움이 될 것으로 기대된다.

  • PDF

Measurements of optical wavelength using WDM coupler (WDM 결합기를 이용한 광파장 측정)

  • 이현우;김용평
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.389-393
    • /
    • 2001
  • A wavemeter is realized using the fact that the coupling coefficient of a WDM coupler is a function of wavelength. Prototype devices with 1500 nm/1600 nm and 1510 nm/1550 nm WDM couplers are successfully fabricated and tested in the laboratory. The measurement resolutions are $\pm$0.27 nm over a wavelength range of 1515 nm~1576 nm for the device with 1500 nm/1600 nm WDM coupler and $\pm$0.103 nm over a wavelength range of 1520 nm~1543 nm for th4e device with 1510 nm/1550 nm WDM coupler. The dependence of operating characteristics on the input signal power is insignificant. However the temperature dependence is ~0.06 nm/$^{\circ}C$.

  • PDF

Large areal particle counting system with CMOS image sensor (CMOS 이미지 센서를 이용한 광영역 입자 계수기)

  • Lee, Seung-Jun;Seo, Yeong-Tai;Ko, Yul;Ji, Chang-Hyeon;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1680-1681
    • /
    • 2011
  • In this paper, particle counting system using a CMOS image sensor is demonstrated. The system utilizes a linear photodetector array as a detection element. Therefore, the particles are detected by large detection region, in contrast to a single detector in conventional particle counting devices, while maintaining the sensitivity. The advantage of proposed system is that particles are detected in a relatively large area without using the particle focusing method. Also, proposed system can be easily integrated with a microfluidic chip by attaching the device underneath the bottom plate of the microfluidic chip. Detection of polystyrene microbeads has been tested at a flow rate of 4.89mm/s. For 21 measurements, proposed system showed an average count error of 7.29% and a standard deviation of 4.74%. Potentially, the proposed system can detect even smaller particles simply by utilizing a higher resolution CMOS image sensor.

  • PDF

전극물질에 따른 단전극 대기압 제트 플라즈마 스트리머 동역학 연구

  • Park, Sang-Hu;Lazovic, Sasa;Jeong, Hui-Su;Chae, Gil-Byeong;Cvelbar, Uros;Choe, Won-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.554-554
    • /
    • 2013
  • 대기압 제트 플라즈마를 저주파(수-수십 kHz) 전압에서 구동 시, 일반적으로 '스트리머(streamer)'혹은 '플라즈마 총알(plasma bullet)'로 불리는 현상이 특정 운전조건에서 관찰된다. 본 연구에서는 동일 구조의 Ta, Ti, stainless steel, brass, Cu, Ni 전극을 이용하여 전극물질에 따른 대기압 제트 플라즈마의 특성 변화를 분석하였다. 각각의 물질은 서로 다른 이차전자방출계수, 일함수, 전기전도도 등 고유한 성질이 다르기 때문에 이들 전극을 이용하여 발생시킨 제트 플라즈마 역시 다른 특성을 갖는다. Acton SpectroPro750 분광기를 이용하여 얻은 플라즈마 방출광스펙트럼으로부터 구한 전자 여기온도(Texc=680~720 K)와 OH의 분자 회전온도(Trot=350~380K)는 물질에 따라 큰 변화를 보이지 않았으나, 발생된 스트리머 거동에서 큰 차이를 확인하였다. ICCD 카메라를 이용한 시간 분해된 이미지에서 전극물질에 따른 첫 번째 스트리머의 발생시간 및 스트리머 속력, 두 번째 스트리머의 분리시간이 모두 다른 것을 확인하였다. 제일 차이가 심하게 나타나는 Ti과 Cu의 경우 첫 스트리머의 발생시간 차이는 약 $1{\mu}s$이며, 평균속력 및 순간속력이 약 2 km/s 차이가 났다. 이 결과를 통해 물질의 이차전자방출계수 및 일함수가 대기압 제트 플라즈마에서 스트리머 발생에 영향을 주는 것을 알았고, 다른 전극물질을 사용한 제트 플라즈마의 특성이 다름에 따라 여러 응용에서의 결과에도 영향을 미칠 것이라생각한다.

  • PDF