• Title/Summary/Keyword: 광흐름

Search Result 164, Processing Time 0.022 seconds

Numerical Investigation of Asymmetric Flow in a Symmetric Channel with Sudden Expansion (대칭 확대 도관에서의 비대칭 흐름에 관한 연구)

  • Min Byeong Gwang;Jang Geun Sik
    • 한국전산유체공학회:학술대회논문집
    • /
    • 1996.05a
    • /
    • pp.68-73
    • /
    • 1996
  • The full incompressible Navier-Stokes equations are numerically integrated to solve the unsteady channel flow using a new numerical scheme of second-order accuracy developed by the authors. It is well known that in spite of the symmetry in the boundary condition and geometry, asymmetry can develop with time-dependency in a channel with sudden expansion. The instability of the shear flow and the cross-channel pressure contribute to such asymmetric flow. In this paper, we successfully generated a channel flow in which vortex waves were propagated downstream due to the harmonically oscillating inlet flow. The structure of the eddies and wall vorticity are parametrically investigated.

  • PDF

Development of Smart Energy Profile(SEP)2.0 Based Home Energy Management System(HEMS) for Photovoltaic(PV), Energy Storage System(ESS) (PV, ESS를 활용한 SEP 2.0 기반의 HEMS 개발)

  • Kim, Byung Min;Lee, Sang Hak;Cho, Sung Ho
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2016.10a
    • /
    • pp.833-834
    • /
    • 2016
  • 최근 에너지 시장의 흐름은 공급위주에서 효율위주로 이동함에 따라 가정 내에서 스마트 그리드와 연동하고 태양광 및 에너지저장시스템을 활용한 에너지 관리 시스템 기술에 대한 연구와 개발이 활발히 진행되고 있다. 하지만 시중에서 판매되는 제품은 인터페이스를 갖추고 있지 않거나 제조사별 독자 프로토콜 사용으로 인한 기존 홍 네트워크와 호환성 문제를 가지고 있다 본 논문에서는 호환성 향상을 위한 SEP2.0 기반의 흉 에너지 관리 시스템 개발과 에너지 관리 스케줄링에 대해 기술하고자 한다.

Design and Implementation of Trouble Ticket System for Network Management (네트워크 관리를 위한 장애처리티켓시스템 설계 및 구현)

  • Kang, Dong-Ho;Ryou, Gi-Sung;Hwang, Il-Sun;Lee, Jae-Kwang
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2000.10a
    • /
    • pp.403-406
    • /
    • 2000
  • 최근 통신망 인프라 구축이 늘어나면서 이의 신뢰성(Reliability)과 가용성(Availability)이 경제 주체인조직 전반의 생산성에 미치는 영향이 그 만큼 커지고 있다. 정보 흐름의 파이프 역할을 담당하고 있는 통신망 시설(하드웨어 및 운용 프로토콜)에 일시적인 장애가 발생할 경우 이로 인해 조직은 엄청난 손실을 입을 수 있다. 따라서 통신망을 안정적으로 운용할 수 있는 보다 효과적인 수단이 요구되고 있다. 통신망에서의 장애를 효과적으로 해결하기 위해서는 장애를 추적하는 장애처리티켓시스템(Trouble Ticket System)이 필요하다. 장애처리티켓시스템은 궁극적으로 네트워크 운영 방식을 획기적으로 개선함으로써 통신망 장애로 인한 시간적, 경제적 손실을 최소화할 수 있다. 본 논문에서는 장애추적해결시스템의 설계와 구현을 통해서 국내 실정에 맞는 장애처리티켓시스템 개발에 적극 활용할 수 있다.

  • PDF

Evaluation Algorithm for Coordination Protection Between Recloser and Distributed Generation Relay (분산전원수용가와 리클로즈의 보호협조 평가알고리즘)

  • Kim, So-Hee;Heo, Sang-Won;Rho, Dae-Seok;Seo, In-Yong
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.05a
    • /
    • pp.69-72
    • /
    • 2011
  • 정부의 녹생성장 정책에 의해서 신재생에너지들의 보급률이 지속적으로 증가되고 있는 실정이다. 특히 배전계통에 태양광/풍력발전 등 분산전원의 설치가 급증함에 따라 기존 배전계통의 조류흐름이 단방향(One direction)에서 양방향(Bi-direction)으로 변화 되어 배전계통의 운용상에 여러 가지 문제점들이 발생할 가능성이 커지고 있다. 따라서 본 논문에서는 분산전원의 배전계통 연계에 따른 보호기기의 정정 및 보호협조검토가 가능한 보호협조 평가알고리즘을 개발하고, 그 알고리즘을 바탕으로 보호협조 평가시스템을 제작하였다. 이 평가시스템에 분산전원 연계 시, 배전계통의 보호기기들 사이의 보호협조를 검토하여 제안한 알고리즘의 유효성을 확인하였다.

  • PDF

비정질합금 자기센서

  • 노태환
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.4
    • /
    • pp.217-224
    • /
    • 1997
  • 컴퓨터를 포함하는 정보통신기기를 비롯하여 TV, VTR, 세탁기 등의 가전기기, 자동차와 항공기 등의 수송기기, 생물 환경 계측기기, 안전 보안기기 등 이루 헤아릴 수 없는 각종 전자, 기ㅖ장비에 광 적외선 센서, 자계 자속 센서, 위치 변위 센서, 역학량 센서, 오도 센서, 응력 센서 등 다양한 센서가 사용되어 기기의 정밀성, 자동화, 신뢰성 및 안정성 등을 획기적으로 향상시키고 있으며, 그 외에 공장생산 현장의 능률 제고와 정밀도의 향상, 안전 쾌적성의 확보, 정보교환 및 전달의 고도화, 일상생활의 고도 시스템화, 사회복지의 구현 등에도 큰 기여를 하고 있다. 그런데 이러한 흐름은 앞으로도 계속되어 전자공학을 필두로 하여, 전력공학, 메카트로닉스 분야와 의공학, 공업계측공학등의 발전을 기초로 하여 산업 및 사회시설의 자동화, 무인화 및 정보화가 빠르게 진전됨에 따라 다양한 센서에 대한 수요가 크게 늘 것으로 예측되고 있다.

  • PDF

건설안전리포트: 소통과 배려로 새로운 안전을 창출하는 현장 - 계룡건설 대전도안지구 동서대로(광로2-10호선) 건설공사 현장

  • Choe, Jong-Deok
    • The Safety technology
    • /
    • no.160
    • /
    • pp.12-14
    • /
    • 2011
  • 대전 서남부 지역 주거환경 개선을 위해 도안신도시가 한창 개발주인 가운데 일부 아파트는 벌써 입주가 완료되면서 신도시로서의 면모가 차츰 갖춰지고 있다. 이 시기에 맞춰 교통의 흐름을 원활히 하기 위한 터널공사와 교야 공사도 함께 분주히 진행되고 있다. 오늘 찾은 현장이 바로 터널공사와 교량고사를 담당하고 있는 계룡건설 대전도안지구 동서대로 건설현장(현장소장 이기욱)이다. 총 연장 1.82km의 편도 4차선터널과 3백여미터의 교량 건설이 한창인 이 곳은 중장비가 연신 들락거리는 가운데 각종 차량과 인력이 유기적으로 들어가며 안전시공, 무재해 시공에 연염이 없다. "신바람 나게 즐기면서 재미있게" 일을 하고 있는 계룡건설 대전도안지구 동서대로 건설현장(이하 동서대로 현장)을 찾아 이들만의 안전 이야기를 들어 봤다.

  • PDF

A Design and Implementation of SCORM Based Authoring System using Multimedia (멀티미디어를 이용한 SCORM 기반 문제 출제 시스템의 설계 및 구현)

  • Chun, Woo-Kwang;Hwang, Chong-Sun
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2004.05a
    • /
    • pp.969-972
    • /
    • 2004
  • 정보 통신 및 인터넷 기술의 급속한 발달로 정보화와 지식기반사회가 도래됨에 따라 교육 분야에도 다양하고 빠른 변화를 보이고 있다. 이런 급속한 발전은 기존의 교육환경이 갖고 있는 시공간의 한계를 뛰어 넘어 언제, 어디서나 자신에게 필요한 학습 활동을 할 수 있다는 기대감이 만들어 졌기 때문이다. 이런 흐름 속에서 본 논문에서는 국제적인 표준으로 자리 잡아가고 있는 SCORM 기술 기반의 문제 출제 시스템을 제작하여 교수자에게는 시간과 장소에 구애됨이 없이 멀티미디어를 이용하여 시청각적 문제를 출제할 수 있게 하였으며, 학습자에게는 보다 효율적으로 학습한 내용을 평가받을 수 있도록 하는데 주안점을 두었다.

  • PDF

REAL-TIME MEASUREMENT OF DENTINAL TUBULAR FLUID FLOW DURING AND AFTER AMALGAM AND COMPOSITE RESTORATIONS (아말감과 복합레진의 수복 과정과 수복 후 발생하는 상아세관액 흐름의 실시간 측정)

  • Kim, Sun-Young;Cho, Byeong-Hoon;Baek, Seung-Ho;Lim, Bum-Sun;Lee, In-Bog
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.6
    • /
    • pp.467-476
    • /
    • 2009
  • The aim of this study was to measure the dentinal tubular fluid flow (DFF) during and after amalgam and composite restorations. A newly designed fluid flow measurement instrument was made. A third molar cut at 3 mm apical from the CEJ was connected to the flow measuring device under a hydrostatic pressure of 15 $cmH_2O$. Class I cavity was prepared and restored with either amalgam (Copalite varnish and Bestaloy) or composite (Z-250 with ScotchBond MultiPurpose: MP, Single Bond 2: SB, Clearfil SE Bond: CE and Easy Bond: EB as bonding systems). The DFF was measured from the intact tooth state through restoration procedures to 30 minutes after restoration, and re-measured at 3 and 7days after restoration. Inward fluid flow (IF) during cavity preparation was followed by outward flow (OF) after preparation, In amalgam restoration, the OF changed to IF during amalgam filling and slight OF followed after finishing. In composite restoration, application CE and EB showed a continuous OF and air-dry increased rapidly the OF until light-curing, whereas in MP and SB, rinse and dry caused IF and OF, respectively. Application of hydrophobic bonding resin in MP and CE caused a decrease in flow rate or even slight IF. Light-curing of adhesive and composite showed an abrupt IF. There was no statistically significant difference in the reduction of DFF among the materials at 30 min. 3 and 7 days after restoration (p > 0.05).

Effect of Irrigation Starting Point of Soil on Chlorophyll Fluorescence, Stem Sap Flux Relative Rate and Leaf Temperature of Cucumber in Greenhouse (시설 토양 오이재배에서 관수개시점 처리가 광합성 형광반응, 줄기수액흐름 및 엽온에 미치는 영향)

  • An, Jin Hee;Jeon, Sang Ho;Choi, Eun Yong;Kang, Ho Min;Na, Jong Kuk;Choi, Ki Young
    • Journal of Bio-Environment Control
    • /
    • v.30 no.1
    • /
    • pp.46-55
    • /
    • 2021
  • This experiment was conducted to investigate the effect on chlorophyll fluorescence, stem sap flux relative rate (SFRR) and leaf temperature of cucumber when irrigation is controlled using a soil moisture tensiometer. Cucumber (Cucumis sativus L.) 'Chungchun' was irrigated of 10-10-20 kPa and 20-10-10 kPa by soil starting point of irrigation at each growth stage. At the 66 days after treatment (DAT) of 736 to 854 W·m-2 and above 32℃, chlorophyll fluorescence variables (Fo, Fm, Fv/Fm) values showed significantly different between treatments. The Fo and Fv/Fm value in the daytime (10:30 am to 6:00 pm) at 66 DAT was higher in 20-10-10 kPa treatment than in 10-10-20 kPa treatment. The Fv/Fm value decreased when the leaf temperature was increased. There was no difference in leaf growth (length, width and area) at 28 and 66 DAT, but the chlorophyll content (SPAD value) was significantly higher in 20-10-10kPa treatment. SFRR and leaf temperature increased with light intensity and temperature increased. In both treatments, the SFRR started to increase sharply between 8 am and 9 am when the solar radiation is 170 W·m-2 or higher. The soil temperature of the treatments decreased after irrigation, that showed 31.0℃ at 10-10-20kPa and 28.5℃ at 20-10-10kPa on July 5 (820W·m-2 at 1 pm). However, there was no difference in SFRR, leaf temperature, temperature difference (leaf temperature - air temperature) and VPD between treatments. SFRR was significantly positive correlate with the leaf temperature (p < 0.01, r = 0.770). The SFRR and leaf temperature showed positive significant correlation with solar radiation, temperature, soil temperature, soil moisture content and VPD. There was a negative significant correlation with relative humidity and temperature difference.

Comparison between Soil Drainage Experiment and Finite Element Analysis for Air Diffusion in Multiphase Porous Media (다공성 매질내의 공기압 확산에 대한 실내 배수시험과 유한요소해석 비교분석)

  • Kim, You-Seong;Kim, Jae-Hong;Kim, Tae-Heon;Lee, Jin-Kwang
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.2
    • /
    • pp.77-85
    • /
    • 2014
  • The paper presents comparison between numerical and experimental results to verify finite element algorithm of air diffusion in three-phase porous media. The theory of two-phase flow in partially saturated soil is a fundamental study to predict the safety for $CO_2$ sequestration. Geotechnical engineering problems exposed to atmospheric pressure generally assume that air pressure is equal to zero in three-phase porous media, but the geotechnical engineering problem at a depth of about over 1 km needs to be considered in connection with deformable solid skeleton due to air pressure. Therefore, the objective of this study is to validate the numerical algorithm by comparing with results obtained from measurement of air diffusion and dissipation through drainage test.