• Title/Summary/Keyword: 광학직경

Search Result 284, Processing Time 0.033 seconds

Development of KITSAT-3 camera and current status of the operation (우리별 3호 지구관측 카메라 개발 및 운용 현황)

  • 이준호;유상근
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.5
    • /
    • pp.382-388
    • /
    • 2001
  • KITSAT-3, launched at May 26 1999, has an earth observation optical payload named MEIS (Multi-spectral Earth Imaging System). The MEIS is a Managin mirror telescope of aperture size of 95mm, and it images the ground with the ground sampling distance of 13.8m over 48km at the altitude of 720km using three different observations bands. This paper first presents the design and then the optics, relating results of manufacturing, integration and test. Finally it briefly discusses the current status of MEIS operation.

  • PDF

Fabrication of X-ray monocapillary optics for soft X-ray fluorescence analysis (경 X선 형광분석을 위한 모세관 광학소자 제작)

  • Cho, Hyung-Wook;Park, Byung-Hoon;Kim, Yong-Min;Choi, Chul-Hee;Choi, Seong-Hee;Kim, Ki-Hong;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.409-413
    • /
    • 2011
  • An X-ray tube used an X-ray fluorescence analysis system has a low X-ray photon intensity which results in reducing measurement accuracy and increasing exposure time. These shortages can be overcame by using a monocapillary optics. A monocapillary optics was optimally designed for focusing the characteristic X-ray of tungsten (8.4 keV). The monocapillary optics can achieve a gain of 10 at the least. The monocapillary optics was fabricated by using puller and pyrex glass, raw material. In fabrication, a weigh of 45g and a temperature of $650^{\circ}$ was loaded. The total fabrication time was 460 minutes. The fabricated capillary had 87 mm in length and maximum diameter of 300 ${\mu}m$ and minimum diameter of 192 ${\mu}m$. When the fabricated monocapillary optics is applied to an X-ray fluorescence analysis system, the detection accuracy for soft elements, for example sulfur (S), will be improved.

Optical constant of the reduced eye based on theoretical finite model eye (이론적 정밀모형안에 기초한 환산모형안의 광학상수)

  • 김상기
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.3
    • /
    • pp.268-273
    • /
    • 2004
  • A finite model eye based on longitudinal spherical aberration is designed by an optimization method. Longitudinal spherical aberration for pupil diameter between 1 mm and 8 mm is graphed theoretically and compared with other model eyes. The chromatic dispersions are adjusted to fit experimentally observed chromatic aberration of the eye. This is a finite model eye with four a spheric refracting surfaces. It has an effective focal length of 15.842 mm. A designed reduced eye has an equivalent power of 63.12 Diopter, curvature radius of 5.281 mm, index of 1.33333, and axial length of 21.123 mm.

Optical Design of Satellite Camera for Lens Shifting Image Stabilization (렌즈 시프팅 영상 안정화 기법 적용을 위한 위성카메라의 광학설계)

  • Tak, Jun-Mo;Hwang, Jai-Hyuk
    • Journal of Aerospace System Engineering
    • /
    • v.10 no.4
    • /
    • pp.17-25
    • /
    • 2016
  • In this study, an optical system for a lens-shifting method that compensates for microvibration of a high-agility small satellite has been designed. The lens-shifting method is an image-stabilization technique that can be applied to compensate for the optical path disturbed by microvibration. The target optical system is designed by using Code-V, a commercial optical-design code. The specifications for real satellite cameras have established the requirements for optical design. The Ray aberration curve, spot diagram, and MTF curve were carried out to verify if the designed optical system meets the requirements or not. The designed Schmidt-Cassegrain optical system with field flattener and a vibration-reduction lens has been verified to meet the optical requirements, 33% of MTF at Nyquist frequency, GSD of 2.87 m, and vibration coefficient of 0.95~1.0.

Optical Design for Satellite Camera with Online Optical Compensation Movements (온라인 광학보정장치를 적용한 위성카메라의 광학설계)

  • Jo, Jeong-Bin;Hwang, Jai-Hyuk;Bae, Jae-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.3
    • /
    • pp.265-271
    • /
    • 2015
  • In this study, optical design for small satellite camera equipped with online optical compensation movements has been conducted. Satellite camera equipped with compensation movements at M2 mirror and focal plane can guarantee the MTF performance through the focal plane image stabilization and the on-orbit optical alignment. The designed optical system is schmidt-cassegrain type that has M1 mirror of a diameter 200mm, GSD 3.8m at an altitude of 700km, and 50 % MTF performance. The performance of the designed optical system has been analyzed through the method of ray aberration curve, spot diagram, and MTF. It has been found by the optical performance analysis that the designed optical system satisfies the optical requirements of satellite camera equipped with online optical compensation movements.

전기전착법으로 성장된 산화아연 나노막대에서 용액 농도, 전류, 온도, 시간이 미치는 효과

  • Park, Yeong-Bin;Nam, Gi-Ung;Mun, Ji-Yun;Park, Seon-Hui;Park, Hyeong-Gil;Yun, Hyeon-Sik;Kim, Yeong-Gyu;Ji, Ik-Su;Kim, Ik-Hyeon;Kim, Dong-Wan;Kim, Jong-Su;Kim, Jin-Su;Im, Jae-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.289.2-289.2
    • /
    • 2014
  • 본 연구에서는 전기증착법 정전류 방법으로 ITO 유리기판 위에 ZnO 나노막대를 성장하였다. 성장 매개 변수로 용액 농도, 전착 전류, 용액 온도 및 성장 시간으로 하였고, 성장된 ZnO 나노막대는 field-emission scanning electron microscopy, X-ray diffractometer, photoluminescence를 이용하여 구조적, 광학적 특성을 분석하였다. 모든 시료에서 ZnO 나노막대는 wurtzite 형태의 결정 구조를 가지고, c-축 배향성을 나타내는 강한 ZnO(002) 회절피크가 나타났다. 용액 농도와 전착 전류가 감소함에 따라 ZnO 나노막대의 밀도 및 직경이 감소하였다. 또한, ZnO 나노막대는 성장 온도가 증가함에 따라 직경이 줄어들었고, 성장 시간이 증가함에 따라 ZnO 나노막대의 길이는 늘어났다. 모든 ZnO 나노막대 시료는 자유 엑시톤 재결합에 의해서 3.18 eV, 산소공공에 의한 결함에 의해서 2.32~1.86 eV의 피크가 관찰되었다. ZnO 나노막대의 직경이 작아질수록 NBEE 피크의 세기가 감소하고, 용액의 농도가 증가함에 따라 NBEE 피크는 청색편이 하였다.

  • PDF

Optimal Design of Secondary Optics for Narrowing the Beam Angle of an LED Lamp with a Large-Area COB-type LED Package (대면적 COB-type LED 패키지를 포함한 LED 램프의 좁은 광속각 구현을 위한 2차 광학계 최적 설계)

  • Kim, Bongjun;Kim, Dae-Chan;O, Beom-Hwan;Park, Se-Geun;Kim, Bongho;Lee, Seung Gol
    • Korean Journal of Optics and Photonics
    • /
    • v.25 no.2
    • /
    • pp.78-84
    • /
    • 2014
  • In this paper secondary optics for an LED lamp with a narrow beam angle of $15^{\circ}$ were optimized by using a two-reflector system, to reduce both its size and the occurrence of satellite rings. The conic constant and the curvature of the primary reflector were determined by considering the relation of the source size to the beam angle, and the optimal position and radius of the secondary reflector were found for reducing the occurrence of satellite rings. Luminous flux efficiency was about 80%.

Sensitivity Analysis of Off-Axis F8 Cassegrain Telescope (초점비 8의 비축 카세그레인 광학계의 민감도 분석)

  • An, Jongho;Kim, Sanghyuk;Pak, Soojong;Jeong, Byeongjoon;Chang, Seunghyuk;Park, Woojin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.2
    • /
    • pp.56.2-56.2
    • /
    • 2015
  • 본 연구에서는 미국 맥도날드 천문대 (Mcdonald Observatory)에 있는 82인치 Otto Struve 망원경의 가이드 망원경으로 사용하기 위해 2개의 반사경을 이용해 구경이 100 mm이고 유효초점거리가 800 mm인 비축 반사망원경을 설계하였다. 비축 반사경은 일반적인 축 대칭인 반사경보다 가공이 매우 어렵기 때문에 형상 정밀도의 요구량을 알 수 있다면 비축 반사경을 가공하는 과정에서 시간과 비용을 절약할 수 있다. 광학계가 수차가 잘 보정된 회절한계의 성능이기 때문에 엔서클드 에너지 직경(Encircled Energy Diameter) 분석을 통해 민감도 분석을 하였다. 광학설계 소프트웨어인 CodeV를 사용하여 80 % 에너지가 $20{\mu}m$ 내에 들도록 공차한계로 설정하였으며, 기준 파장은 $587.56{\mu}m$이다. 또한 부경과 초점 면 사이의 거리를 보상자로 설정하여 공차가 광학계의 성능에 미치는 영향을 최소화하였다. 민감도 분석은 반사경의 위치, 회전, 그리고 반사경의 형상 정밀도에 대해 수행하였다. 분석 결과, 반사경의 위치와 각도는 일반적인 제작 및 조립 공차보다 매우 작은 것을 확인하였다. 그리고 형상정밀도는 주경이 부경보다 민감하였으며 자승 제곱 평균제곱근 (root-mean-square) 32 nm로 가장 민감한 결과가 나왔다.

  • PDF

The comparison and the Analysis of the optical performances between the single and the symmetrical double DOE lenses (단매와 대칭 2매로 구성된 DOE 렌즈의 광학성능 비교 및 분석)

  • 이환선;임천석;조재홍
    • Korean Journal of Optics and Photonics
    • /
    • v.13 no.3
    • /
    • pp.258-265
    • /
    • 2002
  • In this paper, we design single and symmetrical double lenses with DOE. The specifications are the following : Image area is 4.8 mm $\times$ 3.6 mm, F/# is 2.8 and the overall length (from first lens surface to image plane) is 6.8mm. After comparing the optical performance and characteristic values, we determine that symmetrical double lenses are superior to single lenses. Symmetrical double lenses have the merits of fewer zones, weaker flare, and smaller distortion than single lenses.

Study of Uniform Beam Formation at ISOL Target Using TRANSPORT

  • Hong, Seong-Gwang;Kim, Jae-Hong;Kim, Jong-Won
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.174.2-174.2
    • /
    • 2013
  • 사이클로트론에서 가속된 70 MeV 양성자 빔은 stripper에서 인출된 후 ISOL 표적에 조사하게 된다. 이 때 희귀동위원소를 생산하기 위한 ISOL 표적의 온도는 평균 $2,000^{\circ}C$ 5%로 유지하여야 한다. 사용하고자 하는 원판형태의 우라늄 표적은 직경이 45 mm 이므로 50 mm 이상의 균일한 양성자 빔이 필요하다. 본 연구에서는 stripper에서부터 ISOL 표적 까지 빔전송에 필요한 최적 조건을 연구하였다. 총 길이는 15 m 이며 두 개의 dipole을 사용하여 빔을 90도 전환시키며 3개의 4중극전자석을 사용하였다. ISOL 표적에 균일한 빔을 조사하기 위해 wobbling 방법을 활용하여 직경 50 mm 의 균일빔을 발생하고자 한다. 빔 전송 프로그램 TRANSPORT을 이용하여 stripper에서 wobbler 전까지의 빔 광학을 계산한 결과를 보고자 하고 TRANSPORT의 결과를 TURTLE 프로그램에 적용시켜 ISOL 표적에서의 균일도를 5% 미만으로 유지하는 최적조건을 발표한다.

  • PDF