• Title/Summary/Keyword: 광학중심점 높이

Search Result 4, Processing Time 0.021 seconds

The Effect of the Optical Points Difference between Finished-Reading Glasses and Dispensing Reading Glasses (완성품 돋보기와 조제가공된 돋보기가 광학적 요소에 미치는 영향)

  • Shim, Young-Cheol;Yoo, Gun-Chang;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.65-71
    • /
    • 2008
  • Purpose: This paper studied the effect of eyes on the comparison between the distance optical centers problem of dispensing reading glasses made by optician and finished reading glasses in the current market. Methods: The method of this study has been measured by eleven different categories from +1.00D to +4.00D. This study also separated into three groups by their optical frame size and measured optical center point (O.C) and optical center height (O.H) with 200 peoples of man and females over 40 years old without ocular disease living in Gwang-san gu, Gwang-Ju city. Results: As a result, optical center point ranged from 57 mm to 80 mm and it turned to be most common range is from 61 mm to 65 mm (64.6%). Moreover, the optical center height ranged from 1 mm to 8mm and most common ranged (23%) were 4 mm. In other words, finished reading glasses have irregular optical ranges. After observing 200 people who are over 40 years old men and women, result shows that more than 75.5% (151 people) currently use finished reading glasses. Survey of 151 people, most common error between the finished reading glasses's O.C and the wearers P.D were 4 mm (45%). Furthermore, the most common error between the finished reading glassses's O.H and the wearers O.H ranged from 3 mm to 4 mm. Astonishingly, the entire 151 people who wear finished reading glasses appeal that they feel tiredness on their eyes when they wear finished reading glasses. 53 people (35%) claimed that they feel tiredness on their eyes after 10 to 20 minutes wearing finished reading glasses. Base on the research, We conducted more experiment to find the value of prism of optical centers err because it will tell us whether the finished reading glasses are good enough to wear or not. We multiplied diopter by the difference between finished reading glasses's O.C. and wearer's P.D. Consequently, We found out that the finished reading glasses counter to the German RAL-RG 915 policy. And We also found that it is relative to the diopter of lenses. In conclusion, based on the researched that wearing finished reading glasses have a dangerous factor for our vision. Therefore optician must need to recommend correctly made dispensing reading glasses based on the optical center point.

  • PDF

The Clinical Study on Spectacle Wearers of Highschool Students (고등학생 안경착용자의 착용상태에 관안 임상적 연구)

  • Kim, Sang-Kyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2004
  • The purpose of this study is to survey spectacle wearers's way of thinking through the questionaire and to investigate their wearing conditions through fitting conditions, the pantascopic angle, vertex distance, the coincidence of vertical and horizontal distance between optical center of the lens and pupillary distance of the eye in random selected 150 ametropic corrective wearers in the age of 17 to 19. The results are as follows : 1. The most popular causes of physical complaints in the ex-wearing spectacle are frame pressure(34.0%), slipping forward(30.0%) and most popular visual complaints are blur vision(30.0%) and asthenopia(20.0%). 2. The most common physical or visual complaints in the present wearing spectacle are slipping forward(30.0%), pressure (50.0%), color(10.0%). 3. Myopic glasses wearers accounted for 56.7% of the subjects, the others were compound myopic astigmatism. In 60% of the subjects' binocular diopter did not coincide. 4. In the pantascopic angle of the both eyes coincide in 66.7% of the subjects. The average of pantascopic angle is $10.07^{\circ}$. 5. In the vertex distance of the both eyes coincided in 65.3% of the subjects. the he average of vertex distance is 13.6 mm. 6. Among 150 eyes with monocular, the vertical distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG 915 that is tolerance of ophthalmic dispensing in German Standards in 82 eyes (54.6%). 7. Among 150 eyes with monocular, the horizontal distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG915 that is tolerance of ophthalmic dispensing in German Standards in 86 eyes(57.3 %).

  • PDF

Scattered Point Noise Filtering Method for Image Reconstruction Performance Enhancing of White Light Interfrometry (높이영상에 산포되어 있는 점 노이즈 처리를 통한 백색광 간섭계의 영상 복원력 향상)

  • Yim, Hae-Dong;Lee, Min-Woo;Lee, Seung-Gol;Park, Se-Geun;Lee, El-Hang;O, Beom-Hoan
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.1
    • /
    • pp.21-25
    • /
    • 2010
  • In this paper, in order to enhance the image reconstruction performance of white light scanning interferometry(WLI), we demonstrate the scattered point noise filtering performance of post-processing methods. Median filtering is similar to using an averaging filter. Because the median value is less sensitive than the mean to extreme values, the median filter can remove the scattered point noise from a height-map without significantly reducing the sharpness of the image. In several specific cases, however, the median filter can't remove the scattered point noise. Therefore, we propose a comparative mean filter that uses order-statistic filtering and the mean of the neighborhood pixels. The performance is demonstrated by measuring an array of metal solder balls fabricated on PCB. The proposed method reduced the noise pixels by 4.4 percent.

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.