• Title/Summary/Keyword: 광센서 신호

Search Result 211, Processing Time 0.031 seconds

A Study on The low-frequency Hydrophone Using Single-mode FBG in the Hopper Type WDM be in the Making (단일모드 FBG(Fiber Bragg Grating)을 이용한 Hopper type WDM 개발과 저주파수 수중음향 센서연구)

  • Kim, Kyung Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.287-291
    • /
    • 2013
  • The low- frequency hydrophone sensor, using the recently developed FBG has an excellent merits which the existing fiber-optic sensor has and also it has an excellent signal sensing effect in the environment of low-frequency(30Hz-300Hz), not to be detected by the PZT sensor. we have the detection of frequency 19KHz right signals when was using more Hopper lenz WDM than $1{\times}3$ optical coupler. furthermore, we can expect the uitilization of low-frequency signal detection to be used for the military purpose and also it can be developed as the high-sensibility multiplexing through the sensor array system.

광학 분석 시스템용 수.발광 소자 집적 모듈 개발

  • Song, Hong-Ju;Lee, Jun-Ho;Park, Jong-Hwan;Han, Cheol-Gu;Park, Jeong-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.311-312
    • /
    • 2012
  • 본 발표에서는 광학적 분석 시스템에 적용 가능한 발광소자(광원)과 수광소자(광센서)를 집적화시키는 모듈(수 발광 집적모듈) 기술을 제시하고자 한다. 이러한 수-발광 집적모듈은 다양한 응용 분야에 적용 될 수 있다. 예를 들어, 광신호 감지를 위한 광통신용 송-수신 모듈(optical communication), 의료/진단 분야에서 단백질/DNA/박테리아 등의 검출 및 분석에 관한 바이오 센서(bio-sensor), 그리고 대기(가스)/수질 모니터링에 관한 환경센서 등 매우 광범위한 분야에 해당되는 요소 기술이라 할 수 있다. 특히, 이들 분야들 중 바이오 물질을 분석하고 검출하는 광학적 바이오 센서 기술은 높은 경제적 가치와 산업적 성장 잠재력으로 인해 오랫동안 활발한 연구가 진행되어 오고 있다. 이러한 광학적 바이오 센서에서 가장 범용적인 방법 중 하나가 항온-항체 면역반응을 기반으로 하는 형광 검출(fluorescence detection) 기법이다. 이러한 시스템은 전체적으로 광원, 광학계, 그리고 센서로 구성되는데 기존에 일반적으로 사용되고 있는 형광 현미경의 경우는 민감도가 우수하다는 장점은 있으나 상당히 고가이고 부피가 크며 복잡한 광학구성으로 이루어져 있다는 한계점을 가지고 있다. 이러한 맥락에서 고민감도를 확보하면서 휴대성, 고속처리, 저가 등의 특성을 가진 시스템에 대한 요구가 갈수록 증가하고 있다. 이를 해결하기 위한 핵심기술 중의 하나가 수-발광 부분을 집적화 시키는 기술이라 할 수 있다. 본 연구에서는 바이오 센서 기술의 하나로서 형광을 측정하여 혈액내의 진단 지표인자를 검출할 수 있는 휴대용 혈액진단기기에 적용되는 소형 수 발광 집적 모듈을 개발하였다. 혈액내의 검출 성분의 양에 따라 형광의 세기가 변화하게 됨으로써 정량적인 검출이 가능한 원리이다. 모듈의 구조는 크게 광원(발광소자), 광학계, 그리고 광센서(수광소자) 세 영역으로 나누어 진다. 광원은 635 nm 적색 레이저다이오드로서 형광체(Alexa Fluor 647/발광파장: 668 nm)를 여기 시키는 기능을 하며 장착된 볼렌즈 의해 샘플의 형광체 영역으로 집광된다. 광학계는 크게 시준렌즈(collimating lens)와 광학필터로 구성됨으로써 샘플로부터 발생되는 광을 적절하게 수광소자로 전달하는 기능을 하게 된다. 여기서 광학필터의 경우는 기본적으로 Distributed Bragg's Reflector(DBR) 구조로써 실리콘(Si) 포토다이오드 상부에 모노리식(monolithic)하게 형성되며 검출 샘플로부터 진행되는 레이저 광(잡음의 주원인)은 차단하고 형광(광신호)만 통과 시키는 기능을 하게 된다. 따라서 신호 대 잡음비(S/N ratio)를 향상시키기 위해서는 정밀한 광 필터링 기능이 요구됨으로써 박막의 세밀한 공정 조건과 구조적-광학적 특성 분석이 수행되었다. 마지막으로 포토다이오드 소자는 일반적인 구조 이외에 중앙에 원형 구멍이 형성된 특별한 구조가 적용된다. 이것은 포토다이오드 구조에 변화를 줌으로써 모듈 구조를 효율적으로 응용할 수 있다는 의미를 갖는다. 또한 포토다이오드의 전기적-광학적 측정 분석을 통해 잡음 및 감도 특성이 세부적으로 조사되며 형광신호를 효과적으로 측정할 수 있음을 확인하였다. 최종적으로 제작된 모듈은 약 $1{\times}1{\times}1cm^3$ 내외 정도의 크기를 갖는다. 요약하자면 본 발표에서는 광학적 바이오센서에 적용할 수 있는 소형 수-발광 소자 집적모듈을 소개한다. 전체 모듈 설계는 최소한의 부피를 가짐과 동시에 측정의 정밀성을 향상시키는데 초점을 맞추어 진행하였다. 세부요소인 광학필터와 포트다이오드의 경우 잡음 및 민감도에 미치는 중요성 때문에 세밀한 공정 및 특성분석이 수행되었다. 결론적으로 독자적인 설계 및 공정을 통해 휴대성 및 정밀성 등의 목적에 부합한 경쟁력 있는 수-발광 소자 집적모듈 제작 기술을 확보하였다.

  • PDF

Underwater Guidance System for AUV using Optical Sensor Array (광센서 배열을 이용한 무인잠수정의 종단유도장치 시스템)

  • Son, Hyeon-joong;Choi, Hyeung-sik;Kang, Jin-il;Sur, Joo-no;Jeong, Seong-hoon;Kim, Joon-young
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.2
    • /
    • pp.125-133
    • /
    • 2019
  • In this paper, a new study was performed on the docking of AUV to docking station using light and light sensor system under the water. For this, a guiding system for AUV loading sensor system composed of lense, light sensor, signal processor, and processor and docking system with LED are proposed. An analysis on light sensor system and light-collecting lense to obtain accurate relative angle and measurement accuracy was performed. To prove this, the system was built and a basic experiment was performed. Finally, the feasibility of the developed docking system was verified the test in the water tank.

Development of Blood Pressure Measuring System using piezoelectric and photo sensor (광센서와 압력센서를 이용한 맥박측정시스템 개발)

  • Choi, Young-Suk;Kim, Kyung-Jae;Hong, Woo-Heon;Ryu, Jeong-Tak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.149-154
    • /
    • 2009
  • By increasing people's average life span, interest for health is highly growing. According to hoping to check their body condition, people have a medical checkup periodically to check their condition. But, they can prevent disease or are able to make a health care through checking people's pulse or blood pressure. In this paper, two different pulse measurement systems were developed, one system using a photosensor which is able to measure transmissivity's change through blood volume and another system using a piezo-electric sensor which can measure pulse when it measures radial artery's pressure in the wrist are realized. We compared two systems each other.

공진반사광 바이오센서를 이용한 심근경색 마커 감지 기술

  • Heo, Cheol;Kim, Bong-Gyu;Kim, Wan-Jung;Hong, Jong-Cheol;A, Chil-Seong;Kim, Sang-Hyeop;Seong, Geon-Yong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.127-127
    • /
    • 2014
  • 인체 내 소량의 생체성분(혈액, 소변 등)을 감지하는 바이오센서 기술은 질병 진단뿐만 아니라 예방 및 관리로 의료서비스 확대, 개인 맞춤형 진료 및 의료비 감소 효과를 가져올 수 있는 기술이다. 광바이오센서는 광학적인 측정방법을 이용하여 다양한 생화학물질들의 상호 반응을 검출해 낼 수 있는 바이오센서로 현재 활발하게 연구가 진행되고 있다. 광 바이오센서는 생체성분 내에 존재하는 전하를 가진 많은 이온들 및 Salt 농도 등에 영향을 받지 않기 때문에 나노 와이어를 이용한 FET (field-effect transistor)형 바이오센서에 비해 많은 장점을 가지고 있다. 일반적으로 광 바이오센서는 형광물질, 인광물질, 발색물질, 방사선 물질 등의 발광물질을 인식물질에 표지하여 인식물질과 분석물질과의 반응유무를 표지된 발광물질의 광학 신호를 감지하여 분석물질을 검출해내는 표지식 광 바이오센서 기술이 상용화되고 있다. 그러나 이러한 분석 방법은 민감도는 우수하지만 분석 시간이 매우 느리고, 고가의 분석 장비 및 복잡한 제조 공정 등의 단점들을 가지고 있다. 이러한 단점들을 극복하기 위하여 생화학 반응 유무를 표지물질 없이 광학적 방식으로 직접 측정할 수 있는 비표지식 광 바이오센서 기술이 최근 들어 많이 연구되고 있다. 본 논문에서는 광파장 이하의 주기를 가진 주기적 공진 격자 표면에서 일어나는 바이오 항원-항체 반응에 대한 공진 반사 파장을 측정하여 생체성분 내에 존재하는 바이오 항원을 고감도로 검출할 수 있는 비표지식 공진반사광 바이오센서 기술을 소개하고자 한다. 공진반사광 바이오센서를 이용하여 human serum내에 존재하는 심근경색 마커인 troponin I (cTnI), creatine kinase MB (CK-MB), myoglobin (MYO)을 0.1 ng/mL 이하의 농도까지 고감도로 측정할 수 있었다.

  • PDF

High Power Distance & Velocity Measuring SONAR System Development using Two Gated Sinusoidal Signals (두 개의 정현 구동 신호을 이용한 고전력 거리 및 속도 측정 쏘나 시스템 개발)

  • Jang Soon Suck;Ahn Heung Gu;Lee Je Hyeong;Choi Heun Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • spring
    • /
    • pp.363-366
    • /
    • 1999
  • 본 논문은 움직이는 물체의 거리와 속도측정을 위한 고전력 쏘나(SONAR)시스템 개발에 목적을 두었다. 고전력 딘나 시스템은 이동하는 물체에 주파수가 190kHz이고, 1.6ms 만큼의 시간차를 가지는 두 개의 정현 구동신호를 보내, 되돌아오는 초음파의 시간차를 이용했다. 초음파 센서의 송신부에는 고전력 엠프를 사용하여 ${\pm}60V$의 정현 구동 신호가 송신 초음파 센서에 전달 되도록 하였다. 초음파 센서의 신호 발진 및 수신된 신호의 저장을 위하여 IM RAM을 활용하였다. 150-250kHr 대역의 아날로그 BP필터를 거쳐 RAM에 저장된 수신신호는 송신신호와 함께 Cross-correlation을 행하여 시간지 연값을 계산하였고, 이로부터 거리 및 속도를 측정했다. 이 실험에서 설계 제작된 쓰나 시스템으로부터 측정된 값은 오실로스코프와 광 센서를 이용하여 직접 측정한 값들과 비교했다. 그 결과 $2\%$의 오차로 근접함을 확인하였다.

  • PDF

Acousto-Optic Wavelength-Tunable Bandpass Filter (음향광학 파장가변 대역투과 필터)

  • 이명수;황인각;김병윤
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2000.08a
    • /
    • pp.146-147
    • /
    • 2000
  • 광 대역투과 필터$^{(1)(2)}$ 는 WDM 광통신 시스템에서의 채널 선별에 사용되거나 좁은 선폭의 광원을 제작하는 데 사용된다. 또한 광원의 파장을 분석하는 광스펙트럼 분석기나 광섬유 센서 시스템에서 신호처리용 파장 필터 등으로도 널리 쓰이고 있는 중요한 광소자 중에 하나이다. 본 연구에서는 코어 모드감쇠기와 음향광학 가변 필터$^{(3)}$ 를 사용하여 새로운 전광섬유 형태의 광 대역투과 필터를 구현하였다. 본 광 대역투과 필터는 필터의 중심 파장 및 필터의 투과율을 전기적으로 쉽고 빠르게 제어할 수 있다는 장점을 가지고 있다. (중략)

  • PDF

Digital Signal Processing for a Fiberoptic Fabry-Perot Interferometry (초소형 광파이버 패브리페로 간섭계의 디지털 신호처리)

  • Kim, K.S.;Lee, H.S.;Rim, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1820-1822
    • /
    • 2001
  • 광파이버 패브리페로 간섭계에서 동작영역을 넓히기 위해 공진기의 길이를 1mm보다 짧은 초소형 간섭계를 구성하고자 하였을 경우, 광출력의 위상변화에 대한 감도가 낮아 전달함수로부터 변화된 위상을 복원하는 과정이 까다로워진다. 이러한 신호복원 과정에는 대부분 신호잡음비를 높여주는 신호처리 수단을 포함하게 되므로 간섭계가 겪은 위상변화를 보다 높은 신뢰성으로 검출하고자 할 때 어떠한 신호처리 방법이 적절한가하는 선택의 문제가 발생된다. 이는 각각의 신호처리방법이 장단점을 가지므로 응용목적에 따른 trade-off가 필요하기 때문이다. 본 연구에서는 참조 간섭계와 센서 간섭계 간의 correlation으로부터 위상을 검출하여 시스템의 잡음을 common mode 잡음으로 처리할 수 있었으며, 디지털 신호처리기법을 응용하여 짧은 공진기로 구성된 센서 간섭계의 위상변화분을 보다 안정적으로 검출하게 되었다.

  • PDF

Development and comparison of two types MR-Compatible Photoplethysmograph Amplifiers (두 가지 타입의 MR-Compatible 맥파 측정 시스템 개발과 비교)

  • Lee, Gyeong-Sang;Yang, Jae-Ung;Choe, Mi-Hyeon;Lee, Su-Jeong;Jeon, Jae-Hun;Lee, Bong-Su;Jeong, Sun-Cheol
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 2009.11a
    • /
    • pp.148-151
    • /
    • 2009
  • 본 연구에서는 광섬유를 이용하여 반사형과 투과형의 MR-Compatible Photoplethysmograph (PPG) 측정 시스템을 개발하고, 그 성능을 비교하고자 한다. 반사형 타입은 광섬유 다발의 끝단을 피부에 접촉 시킨 후 반사현상을 이용하여 PPG 신호를 측정하고, 투과형 타입은 광섬유 사이에 피부를 접촉시킨 후 투과현상을 이용하여 PPG 신호를 계측한다. PPG 측정 시스템은 광 신호를 검출하는 센서 부분, 근적외선 광 신호를 송수신하는 광케이블 부분, 신호 증폭 부분, 잡음 제거를 위한 필터부분으로 구성되어 있다. 반사형 및 투과형 PPG 신호의 SNR을 비교한 결과 반사형은 23.5dB이고 투과형은 22.2dB로 차이가 거의 없었다. 그러므로 실험 환경이나 목적에 따라 두 가지 타입 중 효율성이 좀 더 높은 것을 선택하여 사용할 수 있을 것이다.

  • PDF