• Title/Summary/Keyword: 광센서 신호

Search Result 211, Processing Time 0.025 seconds

Design and Performance Analysis of an Off-Axis Three-Mirror Telescope for Remote Sensing of Coastal Water (연안 원격탐사를 위한 비축 삼반사경 설계와 성능 분석)

  • Oh, Eunsong;Kang, Hyukmo;Hyun, Sangwon;Kim, Geon-Hee;Park, YoungJe;Choi, Jong-Kuk;Kim, Sug-Whan
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.3
    • /
    • pp.155-161
    • /
    • 2015
  • We report the design and performance analysis of an off-axis three-mirror telescope as the fore optics for a new hyperspectral sensor aboard a small unmanned aerial vehicle (UAV), for low-altitude coastal remote sensing. The sensor needs to have at least 4 cm of spatial resolution at an operating altitude of 500 m, $4^{\circ}$ field of view (FOV), and a signal to noise ratio (SNR) of 100 at 660 nm. For these performance requirements, the sensor's optical design has an entrance pupil diameter of 70 mm and an F-ratio of 5.0. The fore optics is a three-mirror system, including aspheric primary and secondary mirrors. The optical performance is expected to reach $1/15{\lambda}$ in RMS wavefront error and 0.75 in MTF value at 660 nm. Considering the manufacturing and assembling phase, we determined the alignment compensation due to the tertiary mirror from the sensitivity, and derived the tilt-tolerance range to be 0.17 mrad. The off-axis three-mirror telescope, which has better performance than the fore optics of other hyperspectral sensors and is fitted for a small UAV, will contribute to ocean remote-sensing research.

Development of Intelligent Multiple Camera System for High-Speed Impact Experiment (고속충돌 시험용 지능형 다중 카메라 시스템 개발)

  • Chung, Dong Teak;Park, Chi Young;Jin, Doo Han;Kim, Tae Yeon;Lee, Joo Yeon;Rhee, Ihnseok
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.9
    • /
    • pp.1093-1098
    • /
    • 2013
  • A single-crystal sapphire is used as a transparent bulletproof window material; however, few studies have investigated the dynamic behavior and fracture properties under high-speed impact. High-speed and high-resolution sequential images are required to study the interaction of the bullet with the brittle ceramic materials. In this study, a device is developed to capture the sequence of high-speed impact/penetration phenomena. This system consists of a speed measurement device, a microprocessor-based camera controller, and multiple CCD cameras. By using a linear array sensor, the speed-measuring device can measure a small (diameter: up to 1 2 mm) and fast (speed: up to Mach 3) bullet. Once a bullet is launched, it passes through the speed measurement device where its time and speed is recorded, and then, the camera controller computes the exact time of arrival to the target during flight. Then, it sends the trigger signal to the cameras and flashes with a specific delay to capture the impact images sequentially. It is almost impossible to capture high-speed images without the estimation of the time of arrival. We were able to capture high-speed images using the new system with precise accuracy.

DOI Detector Design using Different Sized Scintillators in Each Layer (각 층의 서로 다른 크기의 섬광체를 사용한 반응 깊이 측정 검출기 설계)

  • Seung-Jae, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.11-16
    • /
    • 2023
  • In preclinical positron emisson tomography(PET), spatial resolution degradation occurs outside the field of view(FOV). To solve this problem, a depth of interaction(DOI) detector was developed that measures the position where gamma rays and the scintillator interact. There are a method in which a scintillation pixel array is composed of multiple layers, a method in which photosensors are arranged at both ends of a single layer, a method in which a scintillation pixel array is constituted in several layers and a photosensor is arranged in each layer. In this study, a new type of DOI detector was designed by analyzing the characteristics of the previously developed detectors. In the two-layer detector, different sizes of scintillation pixels were used for each layer, and the array size was configured differently. When configured in this form, the positions of the scintillation pixels for each layer are arranged to be shifted from each other, so that they are imaged at different positions in a flood image. DETECT2000 simulation was performed to confirm the possibility of measuring the depth of interaction of the designed detector. A flood image was reconstructed from a light signal acquired by a gamma-ray event generated at the center of each scintillation pixel. As a result, it was confirmed that all scintillation pixels for each layer were separated from the reconstructed flood image and imaged to measure the interaction depth. When this detector is applied to preclinical PET, it is considered that excellent images can be obtained by improving spatial resolution.

The Study of the Optical Current Sensor Using Magneto-Optic Effects (자기광학효과를 이용한 광전류센서에 관한 연구)

  • 전재일;이정수;송시준;정철우;박원주;이광식;김정배;김민수
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.6
    • /
    • pp.47-53
    • /
    • 2003
  • In this paper, we described the laboratory layout of the optical CT in connection with the measurement of large current based on Magneto-Optic Effects. It was used He-Ne laser for light source and was used PIN-Photodiode for light receiver. The sensing section was organized by winding optical fiber around conductor on the concept that the rotation angle of polarizing axis by Faraday Effect is proportional to the applied current in to conduction. The optical signal passed through optical fiber sensor was induced to analyzer arranged in the direction of $\theta$ for input polarization, and then analyzed its rotation angle and researched on operating characteristics of optical CT for 60[Hz] AC current measurement from l00[A] to 1000[A] was carried out. In this results, the output signals induced linearly with the current and proved that the intensity is increased with increasing turns of fiber through output differences which in accordance with turns of fiber and we verified that there is not only difference of the output with the medium between electric field and optical fiber, but also the lineality. Measuring the references and output intensities of the optical CT, ratio errors were within $\pm$7%. This confirmed that error rate will be improved by each medium and turns.

A Study on the Physical Characteristics of Photoconductors for Photon Counting based X-ray Sensor Application (광계수형 기반의 X선 영상센서 적용을 위한 광도전체 물성 연구)

  • Park, Ji Koon;Noh, Si Cheol;Choi, Il Hong;Jung, Bong Jae;Kang, Sang Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.7
    • /
    • pp.423-428
    • /
    • 2014
  • Digital X-ray imaging devices using a TFT based flat panel array has been used in medical field. But, recently, lots of research on the photon counting sensor has been reported. In this study, we evaluated the physical properties of the photoconductor by suggesting the standard and testing method for quantitative performance evaluation of photon counting x-ray imaging sensor. First, we measured the leakage current and the sensitivity of photon counting x-ray imaging sensor and we evaluated the characteristic of rising time for determining the signal shaping time. In addition, the set-up study was conducted on the basis of the IEC 62220-1-2 recommendations to define the number of incident photons per unit area. And the efficiency of the charge collection was also evaluated. As a result, the characteristic was measured as $200pA/mm^2$ of the leakage current, $7{\mu}C/cm^2R $ of the X-ray sensitivity, and $0.765{\mu}s$ of the rising time.

The fabrication and evaluation of CdS sensor for diagnostic x-ray detector application (진단 X선 검출기 적용을 위한 CdS 센서 제작 및 성능 평가)

  • Park, Ji-Koon;Lee, Mi-Hyun;Choi, Young-Zoon;Jung, Bong-Zae;Choi, Il-Hong;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.2
    • /
    • pp.21-25
    • /
    • 2010
  • Recently, various semiconductor compounds as radiation detection material have been researched for a diagnostic x-ray detector application. In this paper, we have fabricated the CdS detecton sensor that has good photosensitivity and high x-ray absorption efficiency among other semiconductor compounds, and evaluated the application feasibility by investigating the detection properties about energy range of diagnostic x-ray generator. We have fabricated the line voltage selector(LCV) for a signal acquisition and quantities of CdS sensor, and designed the voltage detection circuit and rectifying circuit. Also, we have used a relative relation algorithm according to x-ray exposure condition, and fabricated the interface board with DAC controller. Performance evaluation was investigated by data processing using ANOVA program from voltage profile characteristics according to resistive change obtained by a tube voltage, tube current, and exposure time that is a exposure condition of x-ray generator. From experimental results, an error rates were reduced according to increasing of a tube voltage and tube current, and a good properties of 6%(at 90 kVp) and 0.4%(at 320 mA) ere showed. and coefficient of determination was 0.98 with relative relation of 1:1. The error rate according to x-ray exposure time showed exponential reduction because of delayed response velocity of CdS material, and the error rate has 2.3% at 320 msec. Finally, the error rate according to x-ray dose is below 10%, and a high relative relation was showed with coefficient of determination of 0.9898.

The signal property and structure design of CsI:Na/a-Se for diagnostic x-ray imaging (진단 X선 영상을 위한 CsI:Na/a-Se 구조설계 및 신호특성)

  • Park, Ji-Koon;Heo, Ye-Ji;Park, Jeong-Eun;Park, Sang-Jin;Kim, Hyun-Hee;No, Ci-Chul;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.35-38
    • /
    • 2009
  • Flat-panel x-ray detectors using a phosphor and photoconductor material have been used for application in various medical modalities. In this study, the monte carlo simulation, optical and x-ray response characteristics were investigated in the conversion structure obtained by a columnar CsI:Na scintillation layer with a photosensitive amorphous selenium layer. Firstly, from the measurement of luminescent spectrum of CsI:Na and absorption spectrum of a-Se layer, the signal conversion characteristics are analysed. And also, the x-ray sensitivity is measured and compared with conventional a-Se($500{\mu}m$) as a function of electrical field. From the experimental result, the x-ray sensitivities of the CsI:Na($180{\mu}m$)/a-Se($30{\mu}m$) detector and the a-Se($500{\mu}m$) detector were $7.31nC/mR-cm^{2}$ and $3.95nC/mR-cm^{2}$at an electric field of $10V/{\mu}m$, respectively.

  • PDF

Railway Access Alarm System Using Infrared Distance Sensor and Wireless Communication (적외선 센서와 무선통신을 이용한 열차접근경보시스템 개발)

  • Hwang, Yun-Tae;Hwang, Sung-Tae;Lee, Yun-Sung;Kim, Do-Keun;Lee, Tae-Gyu
    • The Journal of the Korea Contents Association
    • /
    • v.17 no.11
    • /
    • pp.303-311
    • /
    • 2017
  • Safety accidents in railway work continue to increase every year; Engineer's negligence, trackside worker's sensory deprivation and signalman's mistake are the main reasons of such incidents. We consider this problem by far the most urgent matter in railway work because of its steady increase and risk of taking a person's life. Based on that account, a new alarm system has developed, that is called Railway Access Alarm System, to allow railway workers to sense the access of trains with not only vision, but also hearing. The detector device of this system is installed on both sides of the track locating 1.5km from the workplace. When the train enters the place, the detector device can sense the entering, sending the detect sign of train to the alarm unit, then the alarm unit warns the workers by the LED lighting and sirens. This system has several advantages compared to previous systems. First, it recognizes the train at a long distance. Secondly, there is no need for wiring work since it is a wireless system. At last, the system works by rechargeable batteries and solar charger so that it is installed in the work places where there is no external power supply. Moreover, it is proven that the system is 100% reliable by the successful on-the spot inspection evaluating the capability.

A Study on Image Acquisition of Gamma Camera using Simulation LUT and MLPE (시뮬레이션 순람표와 최대우도함수를 이용한 감마카메라의 영상 획득 연구)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.409-414
    • /
    • 2021
  • In order to acquire an image from a gamma camera, linearity correction must be performed. To this end, digital coordinates are acquired by using a linearity map to accurately specify the location where the scintillator and gamma rays interact. In this study, a method for acquiring undistorted images and digital coordinates was developed using a lookup table and maximum likelihood position estimation without using a linearity map. The proposed method was verified by configuring a small gamma camera through DETECT2000 simulation. A gamma camera was constructed using a GAGG scintillator and a SiPM optical sensor, and a gamma-ray interaction was generated at the center of the scintillator, and a lookup table was prepared using the ratio of the signals obtained from the SiPM. Through the prepared lookup table and the maximum likelihood position estimation, the position of the signal obtained by the gamma-ray interaction was acquired as digital coordinates to compose an image. As a result, the linearity was maintained compared to the generally acquired image, the accuracy of the location where the gamma-ray interaction was generated was excellent, and the distance between the locations was uniform. Since the lookup table obtained through simulation is created using the ratio of the signal, it can be directly used in the experiment, and the position of the signal can be conveniently obtained with digital coordinates with corrected linearity without creating a linearity map.

Study on Developing Instrument System for Measuring Action time of K4 Grenade Machine Gun for Improving Quality Assurance on 40mm High Velocity Grenade (40mm 고속유탄의 품질보증 향상을 위한 K4 기관총의 Action Time 계측시스템 개발에 관한 연구)

  • Hong, Sung-Kook;Shin, Jun-Goo;Jeon, Hye-Jin;Kim, Yong-Hwa;Ju, Jin-Chun;Kwon, In-Gyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.7
    • /
    • pp.4828-4834
    • /
    • 2015
  • From the moment that a firing pin triggers the detonator to the moment that a grenade leaves a barrel is called Action Time. Since a loading and percussion of 40mm grenade happens simultaneously, action time should be within a certain time in order to prevent a Jamming malfunction. Previously, unreliable action time device of 40mm grenade made it difficult to improve quality assurance of K4 Grenade Machine Gun. Here, various sensors were compared and a special device was designed to seek an accurate measurement on action time. In this device, the gap between a signal from an optical sensor in Firing Pin and that from Eddy current probe in the barrel was recorded and data were sent to a computer in real time. Confirming if action time is within the criteria, it is expected that action time plays an important role in quality assurance on 40mm grenade.