• Title/Summary/Keyword: 광민감 광섬유

Search Result 28, Processing Time 0.02 seconds

Polymeric digital optical switch based on photobleached waveguides (광표백 폴리머 광도파로를 이용한 디지탈 광스위치)

  • 이상신;신상영
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.414-418
    • /
    • 1996
  • An electro-optic polymer digital optical switch was fabricated by using a photobleached waveguide and a self-aligned electrode. It features wavelength insensitive operation, fabrication tolerance and flexible design. And its possible advantages include low coupling losses to the fibers and wide bandwidths. For improving its switching performance, the guided mode profiles of the photobleached waveguides were controlled by photobleaching times to achieve optimized coupling in the branch. And the self-aligned electrode was employed to achieve both efficient overlap of the optical and electric fields and easy introduction of the adiabatically tapered electrodes. The measured crosstalks were better than -21dB at 1.32 ${\mu}{\textrm}{m}$ and 1.55 ${\mu}{\textrm}{m}$, and the extinction ratios of each output port were also more than 20 dB.

  • PDF

다층 그래핀 필름을 이용한 광섬유 방식 SPR 센서의 생체분자 검출 특성 분석

  • Kim, Jang-A;Kulkarni, Atul;Gang, Jun-Mo;Amin, Rashid;Choe, Jae-Bung;Park, Seong-Ha;Kim, Tae-Seong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.389-389
    • /
    • 2011
  • 최근 생체분자 구조 연구가 의료진단, 생명 현상 규명 및 의약품 개발 등 다양한 분야에 응용되고 있으나 대부분의 분석방법이 제한적이어서 새로운 기술 개발의 필요성이 증대하고 있다. 종래의 DNA 등의 생체분자의 분석은 형광염료를 이용한 방법이 주로 이용되었다. 형광염료는 단백질을 포함한 여러 물질들에 대해 반응하지 않기 때문에 분석에 제한이 있으며, 이와 같은 단점을 보완하는 방법으로 SPR (surface plasmon resonance) 분석법이 연구되었다. SPR은 형광염료 분석에 필수적인 레이블링(labeling) 등의 전처리 과정 없이 높은 민감도로 분석이 가능한 장점이 있다. 한편, 그래핀은 뛰어난 전자기적 성질과 기계적 성질 을 가지는 반금속(semimetal)으로, 실험실 규모에서 안정적인 합성이 실현되면서 그 응용 분야에 대한 연구가 활발히 이루어 지고 있다. 그래핀은 큰 표면적 대 부피비를 가지며, 이는 검출물질과의 반응성이 좋아야 하는 센서기술에 있어서 장점으로 작용한다. 특히, 비금속성을 띠는 단층 그래핀을 여러 장 겹치면 금속성을 갖게 되기 때문에 SPR 센서의 금속 필름으로 응용이 가능하다. 본 연구에서는 SPR 현상을 이용하는 광섬유 센서의 감도와 정확도를 증진시키기 위해 광섬유 표면에 그래핀을 적용하였다. 광섬유는 상부 피복과 클래딩을 제거하여 코어를 노출시킨 후, 다층 그래핀 필름을 코팅함으로써 검출부를 구성한다. 그 후, DNA-biotin 용액, DNA-biotin 용액, 그리고 Streptavidin 단백질 복합 용액에 대한 검출기 신호를 분석하였다. 구성된 센서에 각 용액을 1 ${\mu}{\ell}$ 씩 반응시켜 분광계로 파장에 따른 광강도를 측정하는 실험을 수행했으며, 450 nm에서 460 nm 범위의 푸른빛의 광원을 사용하였다. 그래핀 필름의 유무에 따라 확연히 구분되는 경향을 보이는 결과를 얻었고 그래핀 필름이 기존 SPR 센서의 금속박막을 대체 할 수 있음을 확인하였다.

  • PDF

Analysis of Frequency Response Characteristics in Optical Microphone (광 마이크로폰의 주파수 응답특성 분석)

  • Yeom, Keong-Tae;Kim, Kwan-Kyu;Heh, Do-Geun;Kim, Yong-Kab
    • The Journal of the Korea Contents Association
    • /
    • v.8 no.6
    • /
    • pp.8-15
    • /
    • 2008
  • In this paper, in order to analyze property of frequency response in optical microphone, system was implemented. The capacitance microphone and fiber-optic transmission path type fiber-optic microphone (FOM) have weaknesses in directivity, size, weight, and price. However suggested optical microphone can be constituted by cheap devices, so it has many benefits like small size, light weight, high directivity, etc. Head part of optical microphone which is suggested in this paper is movable back and forth by sound pressure with the attached reflection plate. Operating point is determined by measuring the respond characteristics and choosing the point on which has maximum linearity and sensitivity while changing the distance between optical head and vibrating plate. We measured the output of the O/E transformed signal of the optical microphone while frequency of sound signal is changed using sound measurement/analysis program, Smaart Live and USBPre, which are based on PC, and compared the result from an existing capacitance microphone. The measured Optical microphone showed almost similar output characteristics as those of the compared condenser microphone, and its bandwidth performance was about 300[Hz]-3[kHz] at up to 3 [dB].

Optical Microphone Incorporating a Reflective Micromirror and a Dual-core Collimator (반사형 마이크로미러와 듀얼 코어 클리메이터를 이용한 광 마이크로폰)

  • Song, Ju-Han;Kim, Do-Hwan;Gu, Hyun-Mo;Park, Hyun-Jung;Lee, Sang-Shin;Cho, Il-Joo
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.94-98
    • /
    • 2006
  • An optical microphone based on a dual-core fiber collimator and a membrane type micromirror serving as an optical head and a reflective diaphragm respectively was implemented. The micromirror diaphragm is suspended by a thin silicon bar linked with a frame, thus it is subject to a displacement induced by acoustic waves. The optical head incorporating two collimators integrated in a single housing gives light to and receives it from the diaphragm, rendering the optical microphone structure simple and compact. This dual-core collimator having a slowing varying beam profile facilitates the initial alignment of the optical head with the diaphragm, especially the distance between them. For the assembled microphone, the static characteristics were investigated tofind the operation point defined as the optimum distance between the head and the diaphragm, and a frequency response with a variation of about $\pm$5 dB for the range of up to 3kHz was achieved.

Measurement of Dynamic Strain of Structures Using a Gold-deposited EFPI (금 증착된 광섬유 외부 패브리-페로 간섭( EFPI ) 센서를 이용한 구조물의 동적 변형률 측정)

  • Kim, Dae-Hyeon;Gang, Hyeon-Gyu;Hong, Chang-Seon;Kim, Cheon-Gon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.2
    • /
    • pp.52-58
    • /
    • 2002
  • Measurment of dynamic strain is important to monitor structural integrity. In this paper, the new type of EFPI is proposed to measure the dynamic strain. The second reflecting surface of fiber in this new sensor is deposited gold on to increase its reflectivity. So, it is called the gold-deposited EFPI (G-EFPI) in this paper. In order to explain the principle of measurement of the dynamic strain, two models for the loss of intensity are proposed and an experiment is performed. If a cavity between two reflecting surface increases, the loss of the light that passes through the cavity increases, causing a subsequent decrease in the output intensity of the sensor. Conversely, if the cavity decreases, the amount of loss decreases and the output intensity increases. Also the optimal length of the cavity is proposed to manufacture the G-EFPI with high sensitivity. Finally, the dynamic strainof a composite specimen was measured successfully using the G-EFPI.

A New Recovery Method to Privide Diverse Service Demands for Loss Sensitive Medical Data on IP over WDM Networks (IP over WDM 네트워크에서 손실에 민감한 의료 데이터를 위한 다양한 서비스 요구사항을 만족하는 새로운 복구 방법)

  • Lee, Yonggyu
    • Journal of Digital Convergence
    • /
    • v.20 no.3
    • /
    • pp.377-388
    • /
    • 2022
  • Various researches are actively studied to satisfy exponentially increasing the usage of the Internet as well as the diverse service demands. Especially the Optical Internet that delivers several Tbps through a single optical fiber requires the intelligence to satisfy the various types of survivability requirements. In the paper, a novel recovery scheme that satisfies the various restoration demands in IP over WDM networks is proposed. The scheme classifies the restoration services into three classes and applies dedicated protection and shared restoration scheme with different priorities for each class. Also, a configuration scheme for information database to support the scheme is proposed. This scheme satisfies the different degree of restoration demands in terms of restoration time, blocking rate and resource usage. With the scheme, medical data can be transmitted without loss.

Study on the Development of Optical Sensor Linear Fire Detection System Using Raman Scattering (라만산란을 이용한 광센서 선형 화재감지시스템 개발에 관한 연구)

  • Lee, Gun-Ho;Lim, Woo-Sub;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.27-38
    • /
    • 2016
  • The paper reports the development of a distributed temperature sensing (DTS) system, which is a fire detection system using optical sensor linear detectors that depends on foreign and domestic technologies. This study accordingly analyzed the electrical signal patterns of Raman scattering light mainly used for temperature sensing among back-scattered light generated in optical fiber by using an oscilloscope. Through the measurement results, it could be verified that the Stokes signal patterns had little change by the temperature increase, but the temperature-sensitive anti-Stokes patterns had relative increase of the changes. This study developed a K-DTS system, which is an optical sensor linear fire detection system composed of an optical repeater and a receiver that can detect fires using Raman scattering light. It could be verified that the developed K-DTS system satisfied the type approval standards through the sensitivity tests using the rate of rise type and fixed temperature type sensitivity testers. In addition, performance experiments have been performed for performance evaluation of the K-DTS system developed in comparison with S-DTS system which has been imported from abroad and widely used in Korea. It can be confirmed from the results of the performance experiments using model tunnels that comparable performances can be obtained in fire detection locations and the measurements of fire temperatures.

The Intrusion Sensor Using the Variations of Speckle Patterns (스페클 패턴을 이용한 침입자 센서)

  • Eom, Yeon-Sik;Kim, Yo-Hui;Yang, Seung-Guk;O, Sang-Gi;Kim, In-Su;Park, Jae-Hui;Gang, Sin-Won
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.38 no.3
    • /
    • pp.236-241
    • /
    • 2001
  • The speckle pattern is formed by laser light from a multimode optical fiber. The speckle fluctuation is the result of interference among propagation modes when the optical fiber is subjected to a mechanical perturbation at any point along its length. The experiments were carried on for the study of the feasibility of producing an intrusion detection system using the speckle fluctuation. The speckle fluctuation signals were monitored at real time by an oscilloscope which was connected with a rectifier and a FVC. We used a jig as a PD holder to improve the sensitivity of speckle phenomena and simplify its structure. So we can know the time and magnitude of perturbation.

  • PDF