• Title/Summary/Keyword: 관 환경

Search Result 2,579, Processing Time 0.037 seconds

Behavior of Flexible Pipes with the Accelerated Flowable Backfill Materials Using Surplus Soil for Underground Power Utilities (굴착잔토를 재활용한 지중 전력케이블 유동성 뒷채움재 이용시 지중연성관의 거동특성)

  • Oh, Gidae;Kim, Daehong;Lee, Daesu;Kim, Kyoungyul;Hong, Sungyun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.10 no.7
    • /
    • pp.33-41
    • /
    • 2009
  • In the case of underground power utilities pipe such as circular pipe, the most difficult problem is low compaction efficiency of the bottom of pipe inducing the failure of utilities. To overcome this problem, various studies have been performed and one of these is CLSM (controlled low strength materials) accelerated flow ability. CLSM has already been stage of commercial use in the foreign countries led by power company. In this study, we estimated the behavior of flexible pipe with flowable backfill materials and sand to compare on the DB24 load. The results showed that the deformation of flexible pipe is affected by types of backfill materials. CLSM shows better behavior characteristics than compacting sand. But numerical and analytical results that peformed to compare to the field test results showed big gap with the field results.

  • PDF

A Study on Ozone Generation Characteristic Using Ba-Ti-Si Ceramic Tube (세라믹(Ba-Ti-Si) 방전관의 오존발생특성)

  • Lee, Tae-Gwan;Lee, Dong-Hoon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.543-548
    • /
    • 2006
  • This paper is to be researched into ozone generation character of Bi-Ti-Si type high dielectric ceramic catalyst discharge tube. And conditions of basic experiment are the outside diameter of discharge tube : 52 mm, the length of discharge tube : 350 mm, the frequence : 900 Hz, the temperature of cooling water : $25^{\circ}C$, quantity of flow : 5, 10, 20 L/min, pressure : 1.2, 1.4, 1.6 atm, and distance of discharge gap : 0.4, 0.6, 0.8 mm. Ozone generation characteristics were measured to consumption power. At quantity of flow : 20 L/min, discharge gap : 0.6 mm, pressure : 1.6, and consumption power : 150 W, Maximum ozone generation efficiency of 175 g/kWh was obtained. And a range of maximum ozone generation efficiency was measured below the flow quantity of 20 L/min at below pressure of 1.6 atm. However, Maximum ozone generation efficiency was measured over the flow quantity of 20 L/min at over pressure of 1.6 atm.

Construction of VR Experience Pavilion Using Multi-display and ZA Sensor (멀티디스플레이와 ZA센서를 이용한 가상현실 체험관 구축 방법)

  • Joo, Jae-Hong;Lee, Hyeon-Cheol;Kim, Eun Seok
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2008.05a
    • /
    • pp.28-32
    • /
    • 2008
  • The displays and the interactive interfaces are important factors to enhance immersion in the VR experience pavilion. In the VR experience pavilion displaying 3D Virtual environment, it is difficult to have multi-display with single viewpoint because of the field of view. Also it costs a lot to construct a large size display. The interaction device between user and VR environment necessary to immersion has used mainly the touchscreens with the restricted display area or the button-based input devices so far. In this paper, we suggest a method for constructing extensible multi-display which are showing VR environment in realtime and a method for interaction using a ZA Sensor which is wireless and guarantees the user's unrestricted movement. The proposed method can make a VR experience pavilion more immersive at less cost.

  • PDF

Flood Level Variability Assessment by Hydraulic Characteristics in Storm Sewers (우수관로 수리특성에 따른 홍수위 변동성 평가)

  • Park, Jongpyo;Sim, Inkyeong;Yun, Hyeseon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.426-426
    • /
    • 2021
  • 우수관로의 수리특성에 영향을 미치는 주요 매개변수 중 조도계수 변화에 따른 첨두 수위 변동성을 SWMM으로 분석하고 수위 관측자료와 비교 검증하였다. 모형 적용 조도계수의 범위는 0.015 ~ 0.120이며 0.003 단위로 증가시키며 총 12개 CASE에 대한 모의를 수행하였다. 검토 대상지점은 서울시 방배1, 봉천1, 길동, 신림4, 방배2, 오류1, 천호 배수분구이다. 조도계수 증가에 따른 관내 수위 변동성 검토결과. 방배1 배수분구 22-0001 지점의 경우 조도계수가 0.015에서 0.120으로 증가하면 첨두 수위는 최대 70.3% 높아졌으며 길동 배수분구 25-0003 지점의 경우 103.3%, 신림4 배수분구 21-0002 지점의 경우 78.8% 수위가 상승하였다. 즉, 물리적으로 관로의 조도계수가 증가하면 유속이 감소되고 수위가 증가하는 특성을 보였다. 그러나 상류 인접관로에 만관으로 인한 침수가 발생하는 경우 조도계수가 증가하여도 수위가 상승하지 않는 경우도 있었다. 봉천1 배수분구 21-0004 지점의 경우 조도계수가 0.045를 초과할 때 상류관에서 만관 발생으로 압력관이 형성되며 이러한 영향으로 수위가 상승하지 않는 것으로 분석되었다. 방배2 배수분구의 22-0003 지점, 천호 배수분구의 25-0002 지점의 경우 상류관 침수발생으로 첨두 수위의 역전현상이 발생하였다. 이상의 결과로부터 관로 내 조도계수 증가는 첨두 수위 상승에 큰 영향을 미치며 최대 2배까지 수위가 상승할 수 있음을 알 수 있었다. 반면, 조도계수 상승에 따른 인접관(상류관) 만관 및 침수 발생의 원인으로 일부구간의 경우 수위가 감소하는 경우도 있다. 향후, 유역의 특성, 우수관로의 경사, 규모 등을 고려한 우수관로 수리특성에 따른 수위변동성 분석이 필요할 것으로 판단된다.

  • PDF

Army Field Training and the Affect It Has On the Commissioning of Students Who Hope to Become NCOs (병영실습 훈련이 부사관과 학생들의 임관에 미치는 영향)

  • Jung, Jae-Keak
    • Convergence Security Journal
    • /
    • v.14 no.3_1
    • /
    • pp.71-77
    • /
    • 2014
  • Students in the NCO department who have concluded the agreement with army headquarters, exercise camp education environment and the method on how to carry out the education. In order to raise awareness on NCOs and obtain pride as a future army NCO, army field training is held once a year. The stress on the education is the establishment of national security awareness, proficiency in basic army training, awareness of NCO pride, and basic posture as a soldier. The demand for commissioning only those with satisfactory army field training results is becoming stronger. The satisfaction of the education states a clear goal as a future NCO. This army field training has a meaning when the demands and expectations of the trainee leads to a form of commissioning.

A Study on Disaster Recovery Planning and Automation Support System Implementation in a Data Consolidation Center of Multi-organizations (다기관 통합전산센터의 재해복구체계 및 자동화시스템 구축에 관한 연구)

  • Im, Seong-Muk;Lee, Yeong-Jae
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2004.05a
    • /
    • pp.215-219
    • /
    • 2004
  • 본 연구에서는 다기관 통합전산센터의 다양한 운영모형 분석을 통한 효과적인 운영 대안을 수립하고, 최적 운영대안의 상시운영체계(BCP) 구성방향을 제시한다. 또한 현행 다기관 통합전산센터의 리스크 분석과 리스크 관리 특성을 모형화하여 다기관 통합전산센터의 상시운영계획 이행 절차의 자동화 시스템 구축 방안을 제시한다. 이를 위해 본 연구는 4가지 사항을 중점적으로 다루었다. 첫째, 통합전산센터와 관련한 다양한 용어에 대해 정리를 하고, 통합전산센터의 국내외 사례를 살펴봄으로써 통합전산센터의 중요요소를 도출하였다. 둘째, 다기관 통합전산센터의 논리적 운영모형을 분류하여 각 모형에 따른 장${\cdot}$단점과 실현가능성을 진단하고, 대표적인 모형에 대한 가상환경을 구성하여 운영비용 측면에서 비교하였다. 또한 AHP기법을 이용하여 관련 전문가 인터뷰를 통한 정성적인 측면에서의 비교도 실시하였다. 셋째, 운영모형분석을 통하여 도출된 최적대안에 대한 다기관 통합전산센터의 상시운영체계의 수립 방향에 대하여 기존의 정보시스템을 위한 방법론과의 비교를 통하여 설명하였다. 넷째, 다기관 통합전산센터의 상시운영체계의 구성방향을 반영한 자동화시스템의 기본적인 구축방안에 대하여 간략하게 정리하고 그 기대효과를 제시하였다.

  • PDF

Analysis of Buried Pipelines Using Ground Strain Input from Seismic Waves (지반변형률에 의한 매설관의 지진차 거동 해석)

  • Kim, Moon-Kyum;Cho, Woo-Yeon;Eo. Jun;Lee, Kang-Won
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.4 no.4
    • /
    • pp.15-26
    • /
    • 2000
  • 지진파 전파로 인한 매설관에 작용하는 지진하중은 지진특성 및 지반조건에 따른 지반변형률로부터 산정되어야 한다. 그러나. 기존에 사용되고 있는 경험적인 방법에 의해 계산된 지반변형률 모형은 지진 및 지반의 지역적 특수성을 고려할 수 없는 문제점을 내포하고 있다. 따라서, 본 연구에서는 이러한 문제점을 개선하기 위하여 지진특성 및 지반조선을 반영할 수 있는 수정된 지반변형률 모형을 제안하고 개발된 모형을 매설관로의 지진해석에 지진하중으로 적용하였다. 여기서, 지반변형률을 예측하기 위한 지진판 전파속도는 지반조건을 고려할 수 있도록 파 에너지분포에 근거한 분산곡선을 제안하여 산정하였다. 이러한 과정을 통해 얻어진 지반변형률 산정방법에 타당성을 파악하기 위해 예측한 지반변형률과 과거 지진으로 실측된 지반변형률을 비교하였다. 타당성이 입증된 지반변형률 모형을 매설관의 하중으로 적용하여 지진해석을 실시하였으며, 계산결과는 범용 유한요소해석을 통한 동해석 및 응답변위법에 의한 결과와 비교하였다. 이를 통해 지반 변형률 모형을 적용한 매설관 지진해석의 타당성을 검증하였다. 또한, 지진 및 지반환경이 다른 다양한 관의 특성을 반영하기 위해, 지진 지반 및 관의 영향 인자에 대해 매개변수 해석에 실시되었으며, 이로써 본 연구의 활용성을 검토하였다.

  • PDF

Control of Membrane Fouling in Submerged Membrane Bioreactor(MBR) using Air Scouring (침지형 생물 반응기 공정에서 플럭스 향상을 위한 공기 세척 효과에 관한 연구)

  • Shin, Dong-Hwan;Baek, Byung-Do;Chang, In-Soung
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.9
    • /
    • pp.948-954
    • /
    • 2008
  • Membrane bioreactor(MBR) processes have been widely applied to wastewater treatment for last decades due to its excellent capability of solid-liquid separation. However, membrane fouling was considered as a limiting factor in wide application of the MBR process. Excess aeration into membrane surface is a common way to control membrane fouling in most MBR. However, the excessively supplied air is easily dissipated in the reactor, which results in consuming energy and thus, it should be modified for effective control of membrane fouling. In this study, cylindrical tube was introduced to MBR in order to use the supplied air effectively. Membrane fibers were immersed into the cylindrical tube. This makes the supplied air non-dissipated in the reactor so that membrane fouling could be controlled economically. Two different air supplying method was employed and compared each other; nozzle and porous diffuser which were located just beneath the membrane module. Transmembrane pressure(TMP) was monitored as a function of airflow rate, flux, and ratio of the tube area and cross-sectioned area of membrane fibers(A$_m$/A$_t$). Flow rate of air and liquid was regulated to obtain slug flow in the cylindrical tube. With the same flow of air supply, nozzle was more effective for controlling membrane fouling than porous diffuser. Accumulation of sludge was observed in the tube with the nozzle, if the air was not suppled sufficiently. Reduction of membrane fouling was dependent upon the ratio, A$_m$/A$_t$. For diffuser, membrane fouling was minimized when A$_m$/A$_t$ was 0.27, but 0.55 for nozzle.

표지인물과의 만남-동양환경건설 대표이사 한 상 온

  • Kim, Byeong-O
    • Environmental engineer
    • /
    • v.23 s.244
    • /
    • pp.2-6
    • /
    • 2006
  • ‘환경정책을 입안할 때는 현장에서 직접 관련업에 종사하고 있는 환경기술인들의 의견이 구체적으로 반영되어야 합니다.’ 다년간 환경기술인 생활을 하다가 10여년 전부터 환경산업체인 유한회사 동양 환경 건설의 대표이사직을 맡고 있는 한상온 사장은 현장의 목소리가 정책에 많이 반영 되기를 바라고 있다. 한 사장은 또 현행 양벌 규정에 대해서도 다소 불합리하다고 강조했다. 본지는 지난 23일 연합회 회의실에서 한상온 사장을 만나 그의 환경관을 들어봤다.

  • PDF

환경칼럼 - 21세기 생물다양성 보전의 중심이 되겠습니다

  • Kim, Sang-Bae
    • Bulletin of Korea Environmental Preservation Association
    • /
    • s.411
    • /
    • pp.2-3
    • /
    • 2014
  • 국립생물자원관은 생물산업 육성을 위한 생물자원 활용 기반을 구축하였으며 생물자원 중요성에 대한 인식제고를 위해 많은 노력을 하고 있다. 또한 국가 생물자원 체계화, 멸종위기 야생생물 보호 등 한반도 자생 생물자원을 체계적으로 관리하고 있으며, 유전자원의 접근과 이익공유 체계를 구축하고 생물다양성 관련 국제논의에 적극 대응하고 있다.

  • PDF