• Title/Summary/Keyword: 관통 배관

Search Result 52, Processing Time 0.022 seconds

Evaluation of Pressure History due to Steam Explosion (증기폭발에 의한 압력이력 평가)

  • Kim, Seung Hyun;Chang, Yoon-Suk;Song, Sungchu;Hwang, Taesuk
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.4
    • /
    • pp.355-361
    • /
    • 2014
  • Steam explosions can be caused by fuel-coolant interactions resulting from failure of the external vessel cooling system in a new nuclear power plant. This can threaten the integrity of structures, including the nuclear reactor and the containment building. In the present study, an improved technique for analyzing the steam explosion phenomenon was proposed on the basis of previous research and was verified by simulations involving alumina experiments. Also, the improved analysis technique was applied to determine the pressure history of the reactor cavity in accordance with postulated failure locations. The results of the analysis revealed that the effects of vessel side failure are more serious than those of vessel bottom failure, with approximately 70% higher maximum pressure.

A Study on Status Survey for the Improvement of Shelter Facilities for Residents (주민대피시설의 성능개선을 위한 실태조사에 관한 연구)

  • Park, Namkwun;Kang, Shinwook
    • Journal of the Society of Disaster Information
    • /
    • v.10 no.1
    • /
    • pp.91-97
    • /
    • 2014
  • purpose of this study was to conduct status survey on existing shelter facilities for residents and use it as basic material to plan and design improved shelter facilities in the future. As the result, first, although existing shelter facilities are judged to have been designed in consideration only of the protection from high explosive shells, actual protection capability is significantly low against high explosive shells when exit direction and protection capabilities of main entrances were investigated. Second, all the 7 facilities did not have air purifier with filters installed for the air that flows into the inside from outside and since the height of air exhausts and intake pipes in the outside are also close to the earth, there are possibilities that heavy contaminated air can flow into the inside. Third, although some facilities have anti-explosion doors installed, it is impossible to use them as chemical, biological and radiological (CBR) shelter because of improper installation of openings and anti-explosion valves as well as poor plumbing that cannot ensure air-tightness and poor finish of piping penetration.