• 제목/요약/키워드: 관절면

Search Result 352, Processing Time 0.027 seconds

Limb Salvage Using a Combined Distal Femur and Proximal Tibia Replacement in the Sequelae of an Infected Reconstruction on Either Side of the Knee Joint (슬관절 주위 재건물 감염 후유증 시 슬관절 상하부 종양인공관절을 이용한 사지 구제술)

  • Jeon, Dae-Geun;Cho, Wan Hyeong;Park, Hwanseong;Nam, Heeseung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.1
    • /
    • pp.37-44
    • /
    • 2019
  • Purpose: Tumor infiltration around the knee joint or skip metastasis, repeated infection sequelae after tumor prosthesis implantation, regional recurrence, and mechanical failure of the megaprosthesis might require combined distal femur and proximal tibia replacement (CFTR). Among the aforementioned situations, there are few reports on the indication, complications, and implant survival of CFTR in temporarily arthrodesed patients who had a massive bony defect on either side of the knee joint to control infection. Materials and Methods: Thirty-four CFTR patients were reviewed retrospectively and 13 temporary arthrodesed cases switched to CFTR were extracted. All 13 cases had undergone a massive bony resection on either side of the knee joint and temporary arthrodesis state to control the repeated infection. This paper describes the diagnosis, tumor location, number of operations until CFTR, duration from the index operation to CFTR, survival of CFTR, complications, and Musculoskeletal Tumor Society (MSTS) score. Results: According to Kaplan-Meier plot, the 5- and 10-year survival of CFTR was 69.0%±12.8%, 46.0%±20.7%, respectively. Six (46.2%) of the 13 cases had major complications. Three cases underwent removal of the prosthesis and were converted to arthrodesis due to infection. Two cases underwent partial change of the implant due to loosening and periprosthetic fracture. The remaining case with a deep infection was resolved after extensive debridement. At the final follow-up, the average MSTS score of 10 cases with CFTR was 24.6 (21-27). In contrast, the MSTS score of 3 arthrodesis cases with failed CFTR was 12.3 (12-13). The average range of motion of the 10 CFTR cases was 67° (0°-100°). The mean extension lag of 10 cases was 48° (20°-80°). Conclusion: Although the complication rates is substantial, conversion of an arthrodesed knee to a mobile joint using CFTR in a patient who had a massive bony defect on either side of the knee joint to control infection should be considered. The patient's functional outcome was different from the arthrodesed one. For successful conversion to a mobile joint, thorough the eradication of scar tissue and creating sufficient space for the tumor prosthesis to flex the knee joint up to 60° to 70° without soft tissue tension.

Clinical Outcomes After Arthroscopic Double-Row Rotator Cuff Repair and Evaluation of Cuff Integrity by CT Arthrography (관절경적 2열 고정 회전근개 복원술 후의 임상 결과 및 CT 관절조영술을 이용한 건의 치유 평가)

  • Jo, Chris H.;Kim, Je-Kyoon;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baek;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.199-206
    • /
    • 2009
  • Purpose: Our goal for this study was to prospectively evaluate the functional & structural outcomes, by means of CT arthroscopy, of arthroscopic double-row fixation for treating rotator cuff tear. We also attempted to determine the variants that affect the functional & structural outcomes. Materials and Methods: Twenty seven consecutive patients underwent arthroscopic rotator cuff repair with double-row fixation. The average age at the time of the operation was fifty six years. The preoperative and postoperative examinations consisted of determining the Constant score, the score for the visual analogue scale for pain, the UCLA score, the American Shoulder and Elbow Surgeons (ASES) score, as well as a full physical examination of the shoulder. Preoperative MR arthrography was used to evaluate the integrity and atrophy of the rotator cuff. We measured the intraoperative tear size in the sagittal and coronal planes. Postoperative CT arthrography was used at one year postoperatively to evaluate the integrity and atrophy of the repaired tendons and muscles. Results: Preoperative MR arthrography revealed an average 29.22 mm tear size in the sagittal plane and an average 22.72 mm tear size in the coronal plane. Twelve cases of supraspinatus muscle atrophy and two cases of infraspinatus atrophy were observed on the preoperative MR arthrography. The average clinical outcome scores all significantly improved at the time of follow-up. At a mean of one year postoperatively, CT arthrography revealed 48.1% of the shoulders had healed, 11.1% showed incomplete healing and 40.7% showed retear of the repaired tendon. Conclusion: Arthroscopic double-row repair can result in improved clinical outcomes and good patient satisfaction. However, the problems about how to enhance healing of the repaired tendon still remain.

Anatomical Analysis of Superior Glenoid and Glenoid Labrum (상부 관절와 및 관절와 순의 해부학적 분석)

  • Choi, Nam-Yong;Song, Hyun-Seok;Yoon, Hyung-Moon;Choi, Seung-Gyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.14 no.2
    • /
    • pp.102-106
    • /
    • 2010
  • Purpose: The results of the repair for the superior labrum lesions attaching at the superior glenoid have not been satisfactory in every cases. We wanted to analyze the shoulder MRI and the anatomical morphology and pattern of the superior glenoid at which the superior labrum attaches to get anatomical information helpful in treating the superior labrum. Materials and Methods: We analyzed the coronal images of the shoulder MRI of 108 cases taken at our hospital. Average age was 52 years (range, 17~71 years), 55 males and 53 females. On two coronal images behind the attachment of the long head of biceps that the repair of the SLAP was performed at, the length of the attachment of superior labrum and the angle of the supero-lateral glenoid were measured. Results: The average length of the attachment of superior labrum was $9.78{\pm}1.64\;mm$. The average length was $10.1{\pm}1.61mm$ in male, $9.43{\pm}1.6\;mm$ in female. The angle of the supero-lateral glenoid was $89.6{\pm}7.6$ degrees. Conclusion: The attachment of the superior labrum in coronal plane was shorter in posterior spot than anterior. The angle of the supero-lateral glenoid was less in posterior spot.

  • PDF

The Early Result of Anterior Rotational Osteotomy in the Treatment of Osteonecrosis of the Femoral Head (대퇴골두 무혈성괴사의 치료에서 전방 회전 절골술의 조기 추시 결과)

  • Kim, Se-Dong;Shin, Duk-Seop;Jang, Woo-Seok
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.284-292
    • /
    • 1994
  • In transtrochanteric rotational osteotomy to treat osteonecrosis of the femoral head, the necrotic superior anterior femoral head is rotated anteriorly around the longitudinal neck axis so that the weight bearing force is transferred to the intact posterior surface. The ratio of transposed intact articular surface of the femoral head to the weight-bearing surface of the acetabulum on postoperative anteroposterior view of the hip roentgenograph is the most important indicator of the prognosis. During the period from December 1992 to June 1994, we treated 31 hips in 28 patients who were indicated for the anterior rotational osteotomy among the patients of osteoncrosis of the femoral head. Among the patients, male were 27 and female was one. Age distribution was from 13 to 62 years old and mean age was 44.3. According to the Ficat and Arlet classification, II A was most in number as 16 II B was 7 and III was 8. As their etiolgic factors, alcohol was most in number as 18, steroid was 3, idiopathic was 5 and trauma was 2. The mean rate of the intact area of the posterior part of the femoral head to the total articular surface on the preoperative lateral view of the hip roentgenograph was 41.8%, The mean ratio of transposed intact articular surface of the femoral head to the weight bearing surface of the acetabulum was 53.8%, Fixation devices were screws or dynamic hip screw.

  • PDF

Superior Labral Dimension of the Glenohumeral Joint on Direct MR Arthrography (MRA): Relationship with Presence of SLAP (Superior Labrum Anterior to Posterior) Lesion (직접 자기공명 견관절 조영술 상에서 상부 관절순의 크기: 상부 관절순 전후방 파열과의 관계)

  • Im, Tae Seong;Choi, Jung-Ah;Oh, Joo Han
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.3
    • /
    • pp.193-199
    • /
    • 2014
  • Purpose : To evaluate the relationship between superior labral dimension of the glenohumeral joint on direct MRA and presence of SLAP lesion. Materials and Methods: IRB approval was obtained and informed consent was waived for this retrospective study. Direct MRA studies of the shoulder in 296 patients (300 shoulders) with arthroscopic surgery were analyzed by two radiologists blinded to the arthroscopic results, which were used as gold standard. One of the radiologists reviewed the images twice (session 1 and 2) for the evaluation of intra-observer variability. Transverse and longitudinal dimensions of superior labrum on coronal T1-weighted images were measured as base and height of the inverted triangular-shaped superior labrum and compared between patients with SLAP lesions vs. non-SLAP patients. Presence of meniscoid labrum was noted. Statistical analysis was done using unpaired t-test. Results: Among 279 patients (283 shoulders), 122 patients (43.1%) had SLAP lesions. The mean base/height of superior labrum in SLAP and non-SLAP patients measured on T1-weighted MR image were 8.8 mm / 5.2 mm, 8.5 mm / 4.9 mm for reader 1; 8.2 mm / 4.9 mm, 8.1 mm / 4.5 mm for session 1 of reader 2; 8.0 mm / 4.8 mm, 7.6 mm / 4.3 mm for session 2 of reader 2. In SLAP group, the mean labral height was larger than non-SLAP group with statistically significant difference (p<0.05). Fifteen patients (5.3%) had meniscoid labrum according to operation records. Conclusion: In patients with SLAP lesion, the height of the superior glenoid labrum on oblique coronal image of MRA was slightly larger than non-SLAP patients. A larger height of superior glenoid labrum may be associated with SLAP lesions.

Analysis of Kinematic Parameters of Gait in Normal Subject (정상 성인의 운동 형상학적 보행 분석)

  • Jung, Hwa-Su
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2989-2995
    • /
    • 2014
  • This study was to performed to get the reference data of the kinematic parameters for normal subjects according to the arm movement type. Forty-five normal subjects participated in this study and preformed four sequence according to the arm movement type : normal arm movement, one arm movement, no arm movement, fitness arm movement. The study data was collected from June to August 2010. The kinematic data were measured using Vicon motion system 6MX3 cameras while each subjects walked through a 10m walkway. There were significant differences according arm movement type in the kinematic parameters such as range of motion (ROM) of the right pelvic, hip in sagittal plane, and ROM of the pelvic, hip, lumbar in coronal plane and ROM of the pelvic, thoracic, lumbar in transverse plane. This study can be utilized as the basic reference data in gait analysis for patients with pathologic gaits.

Accuracy Analysis of 3D Posture Estimation Algorithm Using Humanoid Robot (휴머노이드 로봇을 이용한 3차원 자세 추정 알고리즘 정확도 분석)

  • Baek, Su-Jin;Kim, A-Hyeon;Jeong, Sang-Hyeon;Choi, Young-Lim;Kim, Jong-Wook
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2022.07a
    • /
    • pp.71-74
    • /
    • 2022
  • 본 논문은 최적화알고리즘을 이용한 관절각 기반 3차원 자세 추정 기법의 정확도를 휴머노이드 로봇을 이용하여 검증하는 방법을 제안한다. 구글의 자세 추정 오픈소스 패키지인 MPP(MediaPipe Pose)로 특정자세를 취한 휴머노이드 로봇의 관절 좌표를 카메라의 픽셀 좌표로 추출한다. 추출한 픽셀 좌표를 전역최적화 방법인 uDEAS(univariate Dynamic Encoding Algorithm for Searches)를 통해 시상면과 관상면에서의 각도를 추정하고 휴머노이드 로봇의 실제 관절 각도와 비교하여 알고리즘의 정확도를 검증하는 방법을 제시한다.

  • PDF

Wear and Implantation Tilt Measurements using X-ray and CAD (X-ray영상과 CAD를 이용한 인공고관절의 마모 및 식립각 측정법)

  • Lee, Jong Min;Lee, Yeon Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.107-114
    • /
    • 2018
  • Long-term complications such as loosening, wear, osteolytic lesion and granulomatous reaction by foreign bodies can occur, after total hip arthroplasty. The implantation alignment effects dislocation and wear, according to its amount and direction. Wear particles in total hip arthroplasty brings about biochemical complications such as osteolysis or send wear. In this sense, it is important to regularly check wear and alignment of total hip replacement. Because the wear in followup of 10 years may remain in a small amount, like a 1 or 2 mm generally, somewhat precise measurement tool has to be established. The wear and alignment measurement softwares commercially available currently lack in project saving or reproducibility. This study suggests a reliable method for the measurement using an X-ray image and a CAD software. The proposed method can be executed only if having a CAD software under most of current general clinical radiographical environment. The proposed was revealed through tests for the method to have accuracy of 0.06 mm with precision of 0.05 mm for wear measurement, and precision of 0.27 degrees for tilt measurement.

Arthroscopic Reduction and Internal Fixation with Cannulated Screw of a Transverse Glenoid Fracture (유경 나사를 이용한 견갑골 관절와 횡골절의 관절경적 정복 밑 내고정)

  • Noh Kyu Cheol;Yoo Jung Han;Kang Ki Man
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.2 no.2
    • /
    • pp.176-180
    • /
    • 2003
  • We describe in this report the accurate reduction of a transverse displaced glenoid fracture through arthroscopic control . We used the lateral and superior (Neviaser portal) portal of the arthroscopic surgery in the shoulder joint for the U 4.0-mm titanium cannulated cancellous screw fixation. The advantages of this treatment are excellent intra-articular visualiBation, decreased soft tissue dissection ,less blood loss, shortened postoperative recovery and early ROM exercise. There(ore, we report the method of operation and the cases .

  • PDF

Arthroscopically-Assisted Reduction and Internal Fixation of Intra-Articular Fractures of the Lateral Tibial Plateau (관절면을 침범한 경골 외측 고평부 골절에 대한 관절경을 이용한 정복 및 내고정술)

  • Kim, Juhan;Kim, Dong Hwi;Lim, Jae-Hwan;Jang, Hyunwoong;Kim, Young Wook
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.3
    • /
    • pp.227-236
    • /
    • 2019
  • Purpose: To evaluate the results of tibial lateral plateau fractures using arthroscopic-assisted reduction and internal fixation without cortical window or bone grafts. Materials and Methods: From March 2009 to March 2017, 27 patients with Schatzker type II tibial plateau fractures with articular depression and displacement over 5 mm on a computed tomography (CT) scan, who were treated with arthroscopic reduction and internal fixation and followed-up for at least 18 months, were enrolled in this study. Under arthroscopic guidance, the depressed fracture fragment was reduced using a freer and fixed with 5.0 or 6.5 mm cannulated screws through the inframeniscal portal without a cortical window or bone graft. The clinical and radiological results were evaluated using a Rasmussen system. Second look arthroscopy was performed in thirteen patients during the implant removal operation. Results: All fractures healed completely with a mean union time of 8.7 weeks (range from 8 to 12 weeks). Twenty four patients had good to excellent clinical results and 25 patients had good to excellent radiological results according to the Rasmussen classification. A well-healed articular surface with fibrocartilage was also found in 13 cases with second look arthroscopy. The 8 cases on CT scan at outpatient department follow-up showed bone union without bone grafting. Conclusion: Arthroscopic-assisted fixation of tibial lateral plateau fractures is a useful method without a cortical window or bone graft that produces good clinical results.