• Title/Summary/Keyword: 관절경적 건 고정술

Search Result 22, Processing Time 0.022 seconds

Clinical Results of Arthroscopic Biceps Long Head Tenodesis Above the Pectoralis Major Using an Interference Screw (간섭나사를 이용한 관절경적 상완 이두건 대흉근 상부 건 고정술의 임상적 결과)

  • Choi, Sang Su;Kang, Hong Je;Kim, Jeong Woo;Kim, Jong Yun;Kim, Dong Moon;Kim, Kwang Mee
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.2
    • /
    • pp.94-99
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the clinical results of arthroscopic biceps long head suprapectoral tenodesis using an interference screw. Materials and Methods: We reviewed the cases of 30 patients who underwent arthroscopic biceps long head suprapectoral tenodesis using an interference screw between January 2008 and January 2010. The minimum follow up period was one year. Twenty patients had rotator cuff tears. The results were analyzed by VAS, ASES, tenderness in the bicipital groove, fixation failure, and the degree of deformity. Results: VAS, ASES scores showed a statistically significant increase during the final observation in all patients, compared with those before surgery. However, five patients (17%) had anterior shoulder pain and tenderness in the biceps groove, and three patients (10%) had Popeye deformity. Better results were achieved in patients without rotator cuff tear than in patients with rotator cuff tear (p<0.05). Conclusion: Arthroscopic biceps long head tenodesis above the pectoralis major using an interference screw in patients with a pathologic lesion of the proximal biceps tendon showed good results at the last follow up. However, further study for tenderness in the biceps groove in 17% of patients is needed.

Clinical Outcomes After Arthroscopic Double-Row Rotator Cuff Repair and Evaluation of Cuff Integrity by CT Arthrography (관절경적 2열 고정 회전근개 복원술 후의 임상 결과 및 CT 관절조영술을 이용한 건의 치유 평가)

  • Jo, Chris H.;Kim, Je-Kyoon;Yoon, Kang-Sup;Lee, Ji-Ho;Kang, Seung-Baek;Lee, Jae-Hyup;Han, Hyuk-Soo;Rhee, Seung-Whan
    • Clinics in Shoulder and Elbow
    • /
    • v.12 no.2
    • /
    • pp.199-206
    • /
    • 2009
  • Purpose: Our goal for this study was to prospectively evaluate the functional & structural outcomes, by means of CT arthroscopy, of arthroscopic double-row fixation for treating rotator cuff tear. We also attempted to determine the variants that affect the functional & structural outcomes. Materials and Methods: Twenty seven consecutive patients underwent arthroscopic rotator cuff repair with double-row fixation. The average age at the time of the operation was fifty six years. The preoperative and postoperative examinations consisted of determining the Constant score, the score for the visual analogue scale for pain, the UCLA score, the American Shoulder and Elbow Surgeons (ASES) score, as well as a full physical examination of the shoulder. Preoperative MR arthrography was used to evaluate the integrity and atrophy of the rotator cuff. We measured the intraoperative tear size in the sagittal and coronal planes. Postoperative CT arthrography was used at one year postoperatively to evaluate the integrity and atrophy of the repaired tendons and muscles. Results: Preoperative MR arthrography revealed an average 29.22 mm tear size in the sagittal plane and an average 22.72 mm tear size in the coronal plane. Twelve cases of supraspinatus muscle atrophy and two cases of infraspinatus atrophy were observed on the preoperative MR arthrography. The average clinical outcome scores all significantly improved at the time of follow-up. At a mean of one year postoperatively, CT arthrography revealed 48.1% of the shoulders had healed, 11.1% showed incomplete healing and 40.7% showed retear of the repaired tendon. Conclusion: Arthroscopic double-row repair can result in improved clinical outcomes and good patient satisfaction. However, the problems about how to enhance healing of the repaired tendon still remain.

Arthroscopic Repair of Acute Posterior Cruciate Ligament Rupture with Autogenous Hamstring Tendon Graft Augmentation - Technical Note (급성 후방 십자 인대 파열의 관절경하 봉합술 및 자가 슬괵 이식건 보강술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Sung, Kee-Lyong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.70-76
    • /
    • 2005
  • Purpose: We describe a new technique of arthroscopic repair with using autogenous hamstring tendon graft augmentation for the acute posterior cruciate ligament rupture. Operative technique: A routine arthroscopic examination of the knee joint is initially performed, then the posterior trans-septal portal is prepared with the using the posteromedial and posterolateral portals. The torn tibial stump that is retracted to the posterior compartment is repaired by a suture hook that is introduced through the anteromedial portal; visualization during this procedure is done with the arthroscope via the posteromedial portal. Using the retrieved suture, both suture ends are brought out to the anteromedial portal. The torn tibial stump is pulled to the intercondylar notch and then repaired with stitches at the anterior compartment. After the tibial and femoral tunnels are prepared without damaging the remnant PCL bundle, the combined torn PCL fibers and the autogenous single-bundle semitendinosus and gracilis tendon grafts are passed through the femoral tunnel and fixed together Conclusion: Arthroscopic repair of the torn tibial stump and autogenous hamstring tendon graft augmentation after preparing the tibial and femoral tunnels by using the trans-septal portal, without damaging the remnant PCL bundle, seems to be a very effective method for the treatment for acute PCL injuries, and especially for tears at the femoral attachment.

  • PDF

Arthroscoic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Gratt - Effect of the Additional Fixation after Fixation of the Graft with Intrafix - (자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 - INTRAFIX system을 이용한 경골부 고정 후 부가적 고정의 효과 -)

  • Yoo, Jae-Doo;Roh, Kwon-Jae;Shin, Sang-Jin;Yoon, Jong-Suk;Yeo, Sung-Gu
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.1
    • /
    • pp.51-55
    • /
    • 2005
  • Purpose: To compare the stability and clinical result after anterior cruciate ligament reconstructed knee after graft fixation using Intrafix in tibial tunnel with or without additional tibial post fixation. Materials and Methods: We analyzed 37 cases which were treated with four-strand hamstring tendon autograft during the period from May 2002 to January 2003. The grafts were fixed with Rigidfix system (Mitek Product, Johnson and Johnson, USA) in femur tunnel and Intrafix system (Mitek Product, Johnson and Johnson, USA) in tibial tunnel. After tibial fixation, additional tibial post fixation was done, which was determined by the serial case number prospectively. Patients were followed for average of fourteen months(range, thirteen to twenty-five months) At the time of final follow-up, patients were evaluated in terms of Lachman test, pivot shift test, Lysholm scores, IKDC (International Knee Documentation Committee) assessment, side-to-side KT-1000 maximum-manual arthrometer differences. Results: At last follow-up, Lysholm score was average 93.1(range: 65 to 98), IKDC assessment revealed that 26 cases had score of A, 10 cases had score of B and 1 case had score of C. The average maximum-manual KT-1000 arthrometer side ?to-side difference was 2.5 mm$(0{\sim}6mm)$. There was one case in which the Lachman test was graded as 2+ and four cases in which the Lachman test was graded as 1+ and the remaining thirty-two cases were normal by Lachman test. One case had a 2+ pivot-shift, and 2 cases had a 11 pivot-shift. The remaining 34 knees were normal on pivot -shift testing. The average maximum-manual KT-1000 arthrometer side-to-side difference was average 2.8 mm$(0{\sim}6mm)$ in Intrafix only group and average 2.2 mm$(0{\sim}4mm)$ in additional fixation group (P>0.05). Conclusion: Without additional tibial fixation, the stability of the anterior cruciate reconstructed knee with hamstring graft which was fixed with Intrafix was restored.

  • PDF

Effects of Knee Position during the Graft Fixation of the Arthroscopic Anterior Cruciate Ligament Reconstruction with Autogenous Hamstring Graft (이식 건 고정 시 슬관절 위치가 자가 슬괵건을 이용한 관절경적 전방 십자 인대 재건술 후 결과에 미치는 영향)

  • Lee, Churl-Woo;Yoo, Jae-Doo;Roh, Kwon-Jae;Park, Seong-Pil
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.143-147
    • /
    • 2005
  • Purpose: In case of anterior cruciate ligament (ACL) reconstruction, graft tendon is generally fixed in tibial tunnel with knee extended. When reconstructing ACL using hamstring tendon, the authors aim to find out the effect of knee joint position during graft fixation on postoperative knee joint stability and range of motion. Materials and Methods: Prospective study was done on patients who have undergone ACL reconstruction using hamstring tendon from May 2002 to January 2003 We used Rigifix system (Mitek Product, Johnson and Johnson, USA) and Intrafix system for fixation. Thirty nine patients received ACL reconstruction during this period. Excluding 2 patients lost in the follow-up, 37 patients were analyzed. The mean follow-up period was 14 months $(13{\sim}25months)$. Knee position was decided alternatively without any bias. Clinical evaluation was based on Lachman test, pivot shift test, Lysholm score, IKDC(international knee documentation committee) assessment and side to side KT-1000 maximal manual arthrometer difference. Results: After the last follow-up, average postoperative Lysholm score was 93.1 poins(65-98points). According to IKDC score, 26 cases were normal, 10 cases were nearly normal, 1 case was abnormal and we had no case of severe abnormality. The mean difference from the normal side was 2.5 mm under maximal manual loading KT-1000 arthrometer. According to postoperative Lachman test, 32 cases were normal,2 cases were grade I and 1 case was grade II. There were 34 cases of normal, 2 cases of grade I and 1 case of grade II. When using maximal manual KT-1000 arthrometer side to side difference, the difference from the normal side while fixing the tibia at 20'knee flexion was 2.3 mm and at full extention the difference was 2.7 mm. The range of motion at postoperative 1 year showed 5 degree flexion contracture in 1 case at 20 degrees knee flexion and 10 degrees of flexion limitation was observed in 2 cases at full extension. Conclusion: When ACL reconstruction using autogenous hamstring tendon, anterior laxity showed no difference in its stability between two groups. Tibial side fixation at full extension may be helpful in preventing flexion contracture due to overconstrained graft tendon.

  • PDF

Arthroscopic Rotator Cuff Repair by Single Row Technique (회전근 개 파열에 대한 관절경적 봉합술 중 일열 봉합술의 유용성)

  • Yum, Jae-Kwang
    • Clinics in Shoulder and Elbow
    • /
    • v.11 no.2
    • /
    • pp.77-81
    • /
    • 2008
  • The goal of rotator cuff repairs is to achieve high initial fixation strength, minimize gap formation, maintain mechanical stability under cyclic loading and optimize the biology of the tendon-bone interface until the cuff heals biologically to the bone. Single row repairs are least successful in restoring the footprint of the rotator cuff and are most susceptible to gap formation. Double row repairs have an improved load to failure and minimal gap formation. Transosseous equivalent repairs (suture bridge technique) have the highest ultimate load and resistance to shear and rotational forces and the lowest gap formation. Even though the superior advantages of double row and transosseous equivalent repairs, those techniques take longer surgical time and are more expensive than single row repairs. Therefore single row repairs can be useful in bursal side partial thickness or small size full thickess rotator cuff tear.

Arthroscopic Stabilization Using Remplissage Technique In Recurrent Shoulder Instability with Large Hill-Sachs Lesion - Minimum Six Months Follow-Up Results - (광범위한 Hill-Sachs 병변에서 Remplissage 술기를 이용한 관절경적 재건술 - 최소 6개월 이상 추시 결과 -)

  • Ko, Sang-Hun;Jung, Kwang-Hwan;Jeon, Hyung-Min;Park, Han-Chang
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.47-52
    • /
    • 2010
  • Purpose: To evaluate shoulder stability, clinical, and functional results more than 6 months after utilizing the 'Remplissage' technique, consisting of an arthroscopic posterior capsulodesis and infraspinatus tenodesis, to fill Hill-Sachs lesions. Materials and Methods: Seven patients were followed-up more than 6 months after the 'Remplissage' procedures performed in our hospital from August 2008 to August 2009. The mean age of the patients was 28.6 years and the mean follow-up time was 10 months. Evaluations included ROM, ASES score, KSSI score, ROWE score, and postoperative MRI. Results: In a functional evaluation of the patients with an average postoperative time of 10 months, the ASES score improved from 51.4 preoperatively to 76.8 postoperatively, the KSSI score improved from 46.5 preoperatively to 76 postoperatively, and the ROWE score improved from 43.5 preoperatively to 76.3 postoperatively. After an average postoperative time of 10 months, the range of motion was nearly normal (>170 degrees in further flexion, and >45 degrees in external rotation). Conclusion: In recurrent shoulder instabilities with large Hill-Sachs lesions, the 'Remplissage' technique resulted in good outcomes in terms of shoulder stability, clinical, and functional results after postoperative times of more than 6 months.

Lesions of the Long Head Biceps Pulley (상완 이두근 장두 활차 병변)

  • Kim, Chul Hong;Lee, Myung Jin;Kang, Min Soo
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.47-52
    • /
    • 2013
  • Lesions of the long head biceps tendon pulley are frequent causes of shoulder dysfunction and pain. These lesions cause instability of the long head of the biceps tendon (LHB), and intra-articular tear of the subscapularis and the supraspinatus tendon might result from them. The arthroscopic repair of these lesions has not gained widespread acceptance as an effective procedure. Predictable results can be obtained by treating these lesions more definitively with tenotomy or tenodesis. The purpose of this article is to review the anatomy and properties of the LHB pulley and to provide treatment strategies for alleviating pulley lesions.

Anatomic Double-Bundle Posterior Cruciate Ligament Reconstruction Using Achilles Allograft - Preliminary Report - (이중고리 동종 아킬레스건을 이용한 후방십자인대 재건 - 예비 보고 -)

  • Lim, Hong-Chul;Yoo, Jae-Chul;Han, Sang-Hwan
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.7-13
    • /
    • 2002
  • Purpose : Preliminary report of the technique and trial of double bundle PCL reconstruction using Achilles allograft. Materials and Methods : From May 1999 to July 2000, 8 cases of PCL insufficient patients were treated with Achilles allograft reconstruction using the double bundle and double femoral tunnel technique. The tibial tunnel was prepared anteromedially. All other combined injuries within the knees were treated accordingly. Minimal follow-up period was 1 year. The results was assessed from the point of function and stability using Lysholm knee score and KT-2000 arthrometer. Results : Up to present follow up. 8 patients showed good sign of recovery with no instability (translation less than 2 mm) except olio that has been grafted-ligament rupture. In addition, none showed any sign of infection nor ROM limitation. Two complications were seen, which one had grafted-bone fracture and the other grafted-ligament rupture. The former occurred during operation and the latter occurred due to improper protection. Conclusion : Presently the follow up period is too short to draw any conclusive opinion but it is essential to select healthy and well sterilized allografts fur successful outcome. Double femoral tunnel technique seems to be more physiologic in PCL reconstruction. With these prerequisites, it seems to be a good alternative to use Achilles allografts fur the reconstruction of PCL. However, a longer follow-up is needed.

  • PDF

The Results of Arthroscopic Double-Row Rotator Cuff Repairs with Combined Knot-tying and Knotless Suture Anchors (매듭 결속과 비매듭 봉합나사를 이용한 관절경적 이열 회전근개 봉합술의 결과)

  • Ku, Jung-Hoei;Lee, Choon-Key;Cho, Hyung-Lae;Choi, Seung-Hyun
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.3
    • /
    • pp.172-179
    • /
    • 2008
  • Purpose: To evaluate the functional and structural results of arthroscopic double-row repair using combined knot-tying and knotless suture anchors in rotator cuff tears. Materials and Methods: From March 2006 to June 2007, twenty-one patients (15 males, 6 females; mean age 55.6 years; range 48 to 67) were included who underwent arthroscopic double-row repair for full-thickness tears of the rotator cuff following conservative treatment for a mean of 6.5 months (range 3 to 11). The tear size was carefully inspected arthroscopically and we found 2 small, 13 medium and 6 large-sized rotator cuff tears, with a mean tear size of 2.5cm(range 1.8 to 3.2). The repair constructs were consisted of horizontal mattress sutures using conventional knot-tying suture anchors medially and simple suture at the same level of medial row stitch with Bioknotless RC anchors (DePuy Mitek, Norwood, MA) as lateral row. Clinical and functional evaluations were made according to the range of motion, the ASES, UCLA scale and the isokinetic strength testing. Postoperative cuff integrity was determined through magnetic resonance imaging. The mean follow-up was 15 months (range 13 to 24). Results: The average clinical outcome scores and strength were all improved significantly at the time of the final follow-up (p < 0.01). Nineteen patients (90%) were satisfied with the result of the treatment. In 17 of 21 patients (81%) were judged to reveal healed tendon on magnetic resonance imaging at a mean of 7 months postoperatively. There were no significant functional differences according to the preoperative tear size (p<0.01), but large-sized tear shows less favorable structural results in 3 out of 6 cases(50%). Conclusion: Our results document the usefulness and variability of arthroscopic double-row rotator cuff repairs comparable to the results of the other types of double-row repairs.

  • PDF