• Title/Summary/Keyword: 관절경유

Search Result 3, Processing Time 0.042 seconds

Application of Hinged Transarticular External Skeletal Fixator (HTAESF) for Proximal Tibial Physeal Fracture in a Dog (개의 근위 경골 성장판 골절에서 경첩 관절경유 외고정의 적용)

  • Kim, Kwan;Heo, Su-Young;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • v.29 no.6
    • /
    • pp.502-505
    • /
    • 2012
  • An 8-month-old, 3.5 kg intact female Toy Poodle was presented for non-weight-bearing lameness on left hindlimb. In radiological testing, left proximal tibal type II Salter-Harris physeal fracture and fibular fracture were seen. Following open reduction, the fracture was stabilized with cross-pins, tension band wires, and a hinged transarticular external skeletal fixator (HTAESF). The range of the HTAESF was increased to $25^{\circ}$ at 7 days postsurgery and to $70^{\circ}$ at 14 days post-surgery. The HTAESF was removed 3 weeks after surgery. At 6 weeks post-surgery, the fracture was successfully healed with no complications and the patient recovered a normal gait. Seven months post-surgery, the patient had a normal gait and a normal stifle joint range of motion compared to the contralateral normal limb. This is a case in which the combined use of cross-pins, tension band wires, and HTAESF was successful for treatment of a proximal tibial physeal fracture in a dog. It is thought that these methods are beneficial for stability of fracture site and recover of joint's normal range of motion through early joint movement.

Arthroscopic Transosseous Suture Repair for Bankart Lesion with a Flexible Drill Device - An Experimental and Preliminary Clinical Report - (유연성 천공기를 이용한 Bankart 병변의 골관통식 봉합 - 동물 실험 및 예비 임상 결과 보고 -)

  • Park, Jin-Su;Won, Ye-Yeon;Yoo, Jung-Han;Park, Yong-Wook;Noh, Kyu-Chul;Chung, Kuk-Jin;Kim, Hong-Kyun;Hwang, Ji-Hyo;Lee, Young-Bum;Suh, Il-Woo
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.72-78
    • /
    • 2010
  • Purpose: Too develop a flexible drill device that can be inserted into the shoulder joint so that arthroscopic transosseous suture repair for Bankart lesion is possible. Materials and Methods: We created a device composed of a flexible drill unit and a guide pipe unit. The flexible drill unit was made of flexible multifilament wires (1.2 mm in diameter) that was twisted into one cord so that it can flex in any direction and a drill bit (1.2 mm in diameter) that is attached onto one end of the flexible wire. The guide pipe unit was a 150 mm long metal pipe (2.0 mm in inner diameter and 3.0 mm in outer diameter), with one end bent to 30 degrees. The flexible drill set was inserted into the shoulder joint through the posterior portal of the joint. The guide pipe component was placed onto the medial wall of the glenoid so that the pipe was placed 5 mm posterior to the margin of the anterior glenoid rim. The flexible drill was driven through the glenoid by the power drill so that holes were made in the glenoid. A non- absorbable suture was passed through the hole. Tying of a sliding knot tying was accomplished over the capsule and labrum after making a stitch through the capsule and labrum with a suture hook loaded with suture passer. The same procedures were done at the 2 and 4 O'Clock positions of the glenoid. Results: Five cases with Bankart lesion received arthroscopic transosseous repair with our flexible drill device. There were no intraoperative problems. Neither redislocation nor subluxation was reported at final follow-up. Conclusion: Arthroscopic transosseous suture repair without suture anchors and easy tying of a sliding knot are possible with a flexible drill set.

Development and Performance Test of Hydraulic PTO for 50㎾ Class Rotating Body Type Wave Energy Converter (50㎾급 동체회전형 파력발전시스템 유압식 전력변환장치 개발 및 성능시험)

  • Choi, Kyung-Shik;Yang, Dong-Soon;Park, Shin-Yeol;Cho, Byung-Hak
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.3
    • /
    • pp.99-106
    • /
    • 2011
  • 50kW급 동체회전형 파력발전시스템(WEC;wave energy converter)의 전력변환장치(PTO; power take-off)를 설계 제작한 후 성능시험을 하였다. 파력발전시스템은 2개의 실린더형 동체가 회전관절로 연결된 구조로 수면의 반정도 잠기는 구조로 되어있다. 파랑에 의해 유도된 회전관전의 움직임이 유압실린더에 힘을 가해주며, 유압실린더는 고압의 작동유를 축압기를 경유하여 발전기에 체결된 유압모터로 공급한다. 유압식 PTO은 유압실린더가 왕복운동하는 움직임을 이용하여 고품질의 전력을 생산하는데 효과전인 수단을 제공한다. 파력발전시스템의 경제성은 PTO의 에너지 변환 효율에 크게 의존한다. 발전기를 AC 380V 전력계통에 연계시킨 후, 발전기에서 나오는 출력이 5, 20, 35, 43kW 일때 PTO 전체와 개별기기에 대한 효율을 측정하였다. 본 논문에서 유압식 PTO시스템의 설계에 대해 설명하였으며 효율 향상에 초점을 맞추어 PTO 성능대해 분석하였다.