• Title/Summary/Keyword: 관상동기형

Search Result 4, Processing Time 0.028 seconds

Cardiac Surgery for the Patient with VVI Unipolar Pacing System -One Case- (VVI 단극유도의 심박조율치를 가진 환자의 개심술 -1례 치험-)

  • 정해동;최종범;최형호
    • Journal of Chest Surgery
    • /
    • v.31 no.4
    • /
    • pp.398-401
    • /
    • 1998
  • A 56-year-old female with a permanent unipolar pacing(VVI) system underwent elective coronary bypass surgery and mitral valve replacement. Because the unipolar sensing is subject to considerable nonmyocardial electrical noise, the pacing function may be disturbed by the use of electrocautery. Temporary atrial and ventricular bipolar epicardial leads and external generator were used for maintaining A-V sequential pacing during the use of electrocautery. Before aortic cross-clamp was released after cardiac operation, regular cardiac rhythm could spontaneously be resumed with an integrated cardioplegic strategy, avoiding the use of defibrillator

  • PDF

Effect of Diet and Exercise Recommendations Provided by Medical Staff to Patients, and Exercise Self Efficacy with Coronary Artery Disease on Adherence to Regular Exercise (관상동맥질환자에게 제공한 의료인의 식이 및 운동권고, 운동자기효능감이 규칙적인 운동이행에 미치는 영향)

  • Mi-Soo Kweon;Suk-Jeong Lee;Du-Ri Kim
    • Journal of Industrial Convergence
    • /
    • v.22 no.3
    • /
    • pp.91-100
    • /
    • 2024
  • Coronary artery disease(CAD) is associated with a high risk of recurrence and an increased mortality rate upon recurrence. Consequently, there is a need for continuous health behavior recommendations from medical staff. Therefore, a study was conducted on 219 patients hospitalized for coronary angiography. The study aimed to investigate the influence of medical staff recommendations on exercise adherence among CAD patients. In conclusion, regular exercise(RE) recommendation(OR 3.52, p=.036) and dietary advice from medical staff(OR 6.48, p=.022), having high exercise self-efficacy(OR 1.36, p=.001) positively affected RE adherence. Therefore, medical staff should strengthen personalized recommendations for RE and healthy diets, as well as develop exercise self-efficacy enhancement programs to encourage patient participation. Future research is recommended to explore the impact of the degree and method of medical staff recommendations on self-management practices among CAD patients.

An Animal Study on Electrohydraulic Type Ventricular Assist Device (전기 유압식 심실보조장치의 동물실험 연구)

  • 백완기;심상석
    • Journal of Chest Surgery
    • /
    • v.29 no.7
    • /
    • pp.689-699
    • /
    • 1996
  • An animal experiment was designed for the evaluation of in vivo performance of the newly developed electrohydraulic type ventricular assist device and its influence on the left ventricular function during pal- satile left ventricular assist. Eight adult sheep were incorporated into the study and data were collected from seven sheep. Total as- sist time ranged from 69 minutes to 7 days. The performance of the device was satisfactory both in asyn- chr nous and synchronous mode within the range of given native heart rate. More than 4 liters of device output could be reached within the range of normal left atral pressure without development of negative pressure in the left atrium. Moderate to severe degree of hemolysis was noted as evidenced by significant increase of plasma free hemoglobin level after 3 days of left ventricular support along with the presence of the small amount of thrombi around the floating disc type polymer valve apparatus reflecting that further study and refinement of the device need to be done in regard of biocompatibility and thromboresistance. The hemodynamics showed increase in heart rate (p < 0.05), cardiac output and left ventricular minute work (p < 0.05) after placement of the device at the flow rate of 2.0∼2.5 Llmin. The left atrial pressure, left ventricular pressure and LV dpldt were decreased after the device placement(p < 0.05). The endocardial viability ratio and oxygen contents of the mixed ven us blood and coronary venous blood were all increased (p < 0.05) after the device placement suggesting effective unloading of the left ventricle was accomplished. The myocardial perfusion was thought improved in synchronous counterpulsation as suggested by sig- nificant increase in endocardial viability ratio and coronary venous blood oxygen content in synchronous assist mode comparing with asynchronous mode.

  • PDF

The Cox-Maze Procedure for Atrial Fibrillation Concomitant with Mitral Valve Disease (승모판막질환에 동반된 심방세동에서 Cox-Maze 술식)

  • Kim, Ki-Bong;Cho, Kwang-Ree;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.31 no.10
    • /
    • pp.939-944
    • /
    • 1998
  • Background: The sugical results of the Cox-Maze procedure (CMP) for lone atrial fibrillation(AF) have proven to be exellent. However, those for AF associated with mitral valve(MV) disease have been reported to be a little inferior. Materials and methods: To assess the efficacy and safety of the CMP as a combined procedure with MV operation, we studied retrospectively our experiences. Between April 1994 and October 1997, we experienced 70 (23 males, 47 females) cases of CMP concomitantly with MV operation. Results: The etiologies of MV disease were rheumatic in 67 and degenerative in 3 cases. The mean duration of AF before sugery was 66$\pm$70 months. Fifteen patients had the past medical history of thromboembolic complications, and left atrial thrombi were identified at operation in 24 patients. Twelve cases were reoperations. Aortic cross clamp (ACC) time was mean 151$\pm$44 minutes, and cardiopulmonary bypass (CPB) time was mean 246$\pm$65 minutes. Concomitant procedures were mitral valve replacement (MVR) in 19, MVR and aortic valve replacement (AVR) in 14, MVR and tricupid annuloplasty (TAP) in 8, MVR with AV repair in 3, MV repair in 11, MVR and coronary artery bypass grafting (CABG) in 2, MVR and AVR and CABG in 1, redo-MVR in 10, redo-MVR and redo-AVR in 2 patients. The rate of hospital mortality was 1.4%(1/70). Perioperative recurrence of AF was seen in 44(62.9%), and atrial tachyarrhythmias in 10(14.3%), low cardiac output syndrome in 4(5.7%), postoperative bleeding that required mediastinal exploration in 4(5.7%) patients. Other complications were acute renal failure in 2, aggravation of preoperative hemiplegia in 1, and transient delirium in 1 patient. We followed up all the survivors for 16.4 months(3-44months) on an average. Sinus rhythm has been restored in 65(94.2%) patients. AF has been controlled by operation alone in 73.9% and operation plus medication in 20.3%. Two patients needed permanent pacemaker implantation; one with sick sinus syndrome, and the other with tachycardia- bradycardia syndrome. Only two patients remained in AF. We followed up our patients with transthoracic echocardiography to assess the atrial contractilities and other cardiac functions. Right atrial contractility could be demonstrated in 92% and left atrial contractility in 53%.We compared our non-redo cases with redo cases. Although the duration of AF was significantly longer in redo cases, there was no differences in ACC time, CPB time, postoperative bleeding amount and sinus conversion rate. Conclusions: In conclusion, the CMP concomitant with MV operation demonstrated a high sinus conversion rate under the acceptable operative risk even in case of reoperation.

  • PDF