Friction Factors for Flow in Concentric Annuli with Rib-Roughened Wall (돌출형 거칠기벽이 있는 동심환형관의 유동에 대한 마찰계수)

  • Ahn, Soo Whan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.587-592
    • /
    • 1999
  • The combined effects of radius ratio and roughness pitch ratio on the turbulent fluid flow characteristics of the fully developed flow in the annullar tubes with rib-roughened core walls were determined for Reynolds number ranging from 12,000 to 66,000. To understand the underlying physical phenomena responsible for friction factor enhancement, measurements of velocity profiles and zero shear stress and maximum velocity positions were combined to propose the friction factor correlation. Friction factors were found to be a function of the roughness pitch ratio and radius ratio.

Minimum Velocity of Sewerage Pipes (하수관거의 최저유속)

  • Yu, Dong-Hun;Lee, Jeong-Yeong
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.4
    • /
    • pp.469-478
    • /
    • 1999
  • Explicit equations of minimum velocity, energy slope and pipe diameter are developed to ensure the cleaning of sewerage pipes. The equations of power form are employed for the estimation of critical shear stress of sediment particles and the friction factor of commercial pipes. They are all based on the existing laboratory data. Several cases are tested to check the values suggested in the manual, using the equations developed in the present study.

  • PDF

An Experimental Study on the Effect of the Air Temperature on the Air-Side Heat-Transfer Coefficient and the Friction Factor of a Fin-and-Tube Heat Exchanger (외기 온도 변화가 핀-관 열교환기의 공기측 열전달계수와 마찰계수에 미치는 영향에 관한 실험적 연구)

  • Kim, Nae-Hyun;Cho, Honggi
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.4
    • /
    • pp.149-158
    • /
    • 2017
  • In general, the air-side j and f factors of evaporators or condensers are obtained through single-design tests performed under air-dry and wet-bulb temperatures. Considering that the indoor or outdoor air temperatures vary significantly during the operation of an air conditioner, it is necessary to confirm that the experimentally-obtained j and f factors are widely applicable under variable air conditions. In this study, a series of tests were conducted on a two-row slit-finned heat exchanger to confirm the applicability. The results showed that, for the dry-surface condition, the changes of the tube-side water temperature, water-flow rate, and air temperature had virtually no effect on the air-side j and f factors. For the wet condition, however, the f factor was significantly affected by these changes; contrarily, the j factor is relatively independent regarding this change. The formulation of the possible reasoning is in consideration of the condensation behavior underneath the tube. The wet-surface j and f factors are larger than those of the dry surface, with a larger amount for the f factor.

Characteristics of the Interfacial Friction Factor in Countercurrent Two-Phase Flows (반류 2상유동에서의 계면마찰계수의 특성)

  • 이상천;김동수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.1
    • /
    • pp.299-307
    • /
    • 1991
  • A unified correlation of the interfacial friction factor for air-water and steam-water flows in inclined rectangular channels has been developed. The correlation was expressed in the form of a power law of the liquid and the gas Reynolds number, and the liquid-to-gas viscosity ratio. In addition, a relation between the equivalent roughness and the intensity of wave height fluctuation of the interface has been investigated. A new dimensionless intensity of fluctuation including a liquid film Reynolds number is proposed. It has been shown that the dimensionless equivalent roughness, which is calculated from the Nikuradse equation, can be uniquely related to this dimensionless intensity of fluctuation for both air-water and steam-water flows.

Condensation Heat Transfer and Pressure Drop in Flat Tubes with Different Aspect Ratios (종횡비가 다른 납작관 내 응축열전달 및 압력손실)

  • Kim, Nae-Hyun;Park, Ji-Hoon;Cha, Sang-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.12
    • /
    • pp.1111-1119
    • /
    • 2010
  • In this study, condensation heat transfer coefficients of R-410A were obtained in flattened tubes made from round tubes with an inner diameter of 5.0 mm. The saturation temperature was $45^{\circ}C$; the heat flux, 10 kW/$m^2K$; the mass flux, 100-400 kg/$m^2s$; and the quality, 0.2-0.8. The results showed that the effect of the aspect ratio on the condensation heat transfer coefficient depended on the flow pattern. For annular flow, the heat transfer coefficient increased as the aspect ratio increased. For stratified flow, however, the reverse was true: the pressure drop increased as the aspect ratio increased. Existing correlations adequately predicted the heat transfer coefficients and pressure drops of the flattened tubes.

A Estimation and Analysis of Characteristics for Hazen-Williams C Value of Water Pipe System (상수관로 유속계수 산정 및 특성 분석)

  • Kim, Kyoung Oh;Kim, Se Min;Park, Yung Ki
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.239-239
    • /
    • 2019
  • 상수도시설 중 배수관망시설은 해당 지역의 영향을 민감하게 받는 시설이므로 설계시 해당시설의 특성을 충분히 고려해야 한다. 배수시설은 설치된 해당지역에 따라 그 특성이 매우 다르기 때문에, 설계지표 또한 해당 도시마다 다르게 설정될 수 있다. 도시의 규모가 크거나, 그 특성이 해당 구역에 따라 다른 경우에는 같은 도시의 경우라도 대상구역에 따라 다른 지표를 사용하는 경우도 있다. 따라서 이런 상수도관망의 설계 및 관리를 위해서는 장기간 현장여건에 맞는 관측자료를 통한 정밀한 수리분석이 요구되며 국내의 경우 일반적으로 Hazen-Williams 공식을 사용하고, 이때 관내면의 마찰손실계수 C는 유속계수라 한다. 이러한 유속계수는 상수관로의 물리적 특성을 나타내며 관로 내의 흐름해석, 펌프 및 관로의 설계, 최적 운영 방안, 통수능력 및 관 노후도 평가 등에 사용되거나 영향을 미치는 중요한 요소라 평가되고 있다. 또한 다수의 현장 관측 자료를 확보하여도 분기 구간과 펌프 및 밸브 등으로 인한 손실 등의 오차가 발생하므로 유속계수 산정 시 발생되는 많은 오차들을 줄여 보다 신뢰성 있는 유속계수를 산정해야 하고, 현장 관측 자료를 이용하여 유속계수를 산정하기 어려운 구간에 대해서는 관망해석 모델링을 통하여 결정하고 있다. 본 연구에서는 전주권 광역상수도의 계통 특성에 맞는 관로의 유속계수를 결정하기 위해 관리주체에서 기존에 설치한 수압계와 유량계 및 관망도를 이용하여 기초자료를 수집하고 Hazen-Williams 공식을 이용하여 유속계수를 산정하였다. 계산된 상수관로 유속계수는 전주시의 10개 계통에서 최소 107.06, 최대 145.02, 평균 127로 계산되었으며, 유속계수에 영향을 미치는 물리적 요소들의 관계를 파악하고자 상관성 분석 실행하였다. 그 결과 관경과 경과년수의 상관계수 R은 0.011 관경과 유속계수의 상관계수는 -0.009로 두변수간의 상관성이 거의 없고, 경과년수와 유속계수의 상관계수는 -0.776로 음의 상관성을 갖는 것으로 분석되었다. 이와 같이 제시한 유속계수는 해당 지역의 참고자료나 기준으로서 활용할 수 있을 것으로 판단되며 비 대상 지역에서도 현장자료가 부족한 곳의 유속계수를 산정할 경우 보다 신뢰성 있게 유속계수를 산정할 수 있는 방법을 제시하고자 한다.

  • PDF

Convective Heat Transfer Correlations for the Compact Heat Exchanger with Circular Tubes and Flat Tubes-Plate Fins (원형관 및 납작관-평판휜 형상의 밀집형 열교환기에 대한 대류열전달 상관관계식)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.3
    • /
    • pp.291-299
    • /
    • 2010
  • Aspect-ratio-based numerical analysis is carried out to investigate the air-side convective heat transfer characteristics in compact heat exchangers with circular tubes and flat tubes-plate fins. The RNG $k-{\varepsilon}$ model is adopted for turbulence analysis. The numerical analysis is carried out for aspect ratios ranging from 3.06 to 5.44 and for Reynolds numbers ranging from 1,000 to 10,000. The calculated results indicate a correlation between the friction factor and Colburn j factor in the compact heat exchanger system for the range of aspect ratios under consideration. The results obtained for circular tubes and flat tubes-plate fins in this study can be utilized to realize the optimal design of an air conditioning system.