• Title/Summary/Keyword: 관로시스템

Search Result 275, Processing Time 0.038 seconds

Analysis of Pipe-Burst effect in Water Distribution Network (상수관망의 관로파열 영향 해석)

  • Park, Jae-Hong
    • Journal of Korea Water Resources Association
    • /
    • v.35 no.6
    • /
    • pp.665-675
    • /
    • 2002
  • It is very closely related with the reliability of the pipe network to predict pipe burst and diminish burst effect in water distribution system. Most of the engineers have not consider pipe layout and the effect of pipe burst in conservative pipe network design. In this study, The effect of pipe burst in the network is analyzed with respect to pipe network geometric topology and the method of increasing the system reliability is presented by reducing pipe-burst effect. In existing pipe system, it is only designed to the closed loop system but in case of each pipe burst, it cannot transmit appropriate water to consumers and occurs severe hydraulic head drop in many nodes. The techniques developed in this study allow proper pipe diameter and pipe layout to pipe system through the analysis of pipe-burst effect. Thus, when each pipe is bursted, pipe system is prevented from severe pressure head drop in demand nodes and can supply stable flowrate to consumer.

The Inner Pipeline Scanning Method by Digital Image Processing and Lens Combination (영상처리기법과 렌즈조합에 의한 관로내 탐사기법)

  • Kim, Won-Dae
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.16 no.1
    • /
    • pp.67-73
    • /
    • 2008
  • The most common method of pipeline inspection is to use a remote-controlled-machine equipped with a CCTV, which, however, has many limitations to accurately inspect pipeline condition. In case of a typical CCTV, since the camera looks at the end point of the pipe, the locations of the defects and distance-readings are often different. In addition, the quality and accuracy of the inspection is highly dependent on the operator's skill and experience. In this research a new system is developed by use of the image processing techniques and the lens combination. The image acquisition system is developed that acquires the front and the side view of the pipe simultaneously. Side view unwrapping and stitching technology using image process techniques are developed which delivers high resolution image data.

  • PDF

Study on the Decision Priority of Rehabilitation for Water Distribution Network Based on Prediction of Pipe Deterioration (상수관로 노후도 평가를 통한 개량 우선순위 결정에 관한 연구)

  • Park, In-Chan;Kwon, Ki-Won;Cho, Won-Cheol;Cho, Kwan-Hee
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2006.05a
    • /
    • pp.1391-1394
    • /
    • 2006
  • 노후 상수도관의 개량사업이 지속적으로 시행되고 있지만 노후관 개량사업은 경험적 판단에 의존하는 노후관 평가 및 대안의 선정, 사고예방을 위한 대응적 차원의 개량 사업을 실시함으로 인해 경제적 손실은 물론 시스템의 유기적 기능향상이 이루어지지 않고 있는 실정이다. 이에 본 연구에서는 상수관로 중에서 아연도 강관, 도복장 강관, 닥타일 주철관을 선정하여 현장조사를 실시하였으며, 직접 채취된 관체 시편을 대상으로 육안분석, 관체분석, 그리고 토양부식성 등을 평가하여 채취한 관의 노후도를 종합적으로 평가하였다. 기본적으로 노후도 평가를 점수 평가법을 사용하였으며, 평가된 결과를 바탕으로 향후 노후 수도관 개량사업 추진 내용에서 개대체 우선순위를 결정하기 위한 모델을 제안하였다. 상수관로 노후도 영향 인자 및 가중치 추정은 현재 매설된 상수관로의 노후진척도를 평가하기 위한 노후도 예측모형의 기본 요소이며, 모형의 정확도를 향상시키기 위해 필수적인 사항이다. 관로 노후진척도 분석의 정확도는 장기간의 자료 수집을 통하여 이루어져 이에 대한 분석이 필요하며, 대상관로를 이용하여 개발된 제안식은 향후 지속적으로 현장조사를 실시하여 보완이 필요하겠지만, 노후수도관의 개량 우선순위를 분석하기 위한 매우 유용한 자료가 될 것으로 판단한다.

  • PDF

The deployment Advanced Technology of Water supply line breakage detection system in Songsan Green City (송산그린시티(동측)내 선진 상수관로파손감시시스템 구축기술)

  • Kwag, Jun keun;Park, Ji Young;Yoon, Sang Jo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.05a
    • /
    • pp.291-295
    • /
    • 2022
  • This paper deal with the advanced thchnology of water supply line breakege detection system in singsan green city. the technology apply for construction eco oriented high-tech city to merge residant, industial, tour reasure parts for songsan green city furture direction achivement and response for a life style change of people in the city. Breakege detection system consist of smart prevention seat, pipeline breakege detection sensor, analysis software, server. etc.. Central control unit sent the data to hwa sung city water supply office by WCDMA in SKY. the data are states about water supply pipeline, Location.etc. This system maintain the long term life cycle of water supply plpeline by the prevention the leakege event through ackonwledge information of evnet occurrence locaion. and used to realtime sense method about demage information of the pipeline and prevent to brekege facilities during excavation work.

  • PDF

Development of real-time defect detection technology for water distribution and sewerage networks (시나리오 기반 상·하수도 관로의 실시간 결함검출 기술 개발)

  • Park, Dong, Chae;Choi, Young Hwan
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1177-1185
    • /
    • 2022
  • The water and sewage system is an infrastructure that provides safe and clean water to people. In particular, since the water and sewage pipelines are buried underground, it is very difficult to detect system defects. For this reason, the diagnosis of pipelines is limited to post-defect detection, such as system diagnosis based on the images taken after taking pictures and videos with cameras and drones inside the pipelines. Therefore, real-time detection technology of pipelines is required. Recently, pipeline diagnosis technology using advanced equipment and artificial intelligence techniques is being developed, but AI-based defect detection technology requires a variety of learning data because the types and numbers of defect data affect the detection performance. Therefore, in this study, various defect scenarios are implemented using 3D printing model to improve the detection performance when detecting defects in pipelines. Afterwards, the collected images are performed to pre-processing such as classification according to the degree of risk and labeling of objects, and real-time defect detection is performed. The proposed technique can provide real-time feedback in the pipeline defect detection process, and it would be minimizing the possibility of missing diagnoses and improve the existing water and sewerage pipe diagnosis processing capability.

Study of Surges in a Large-Diameter Subteranean Diversion Channel with Multiple Surge Tanks (대심도 지하관로 배수 시스템의 서어징 현상에 관한 연구)

  • Jeong, Gwang-Geun;Yeo, Un-Sik;An, Tae-Jin
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.6
    • /
    • pp.757-768
    • /
    • 1998
  • rate of outflow is equated to the total rate of flow, both the state equation and its linearized equation yield almost identical oscillations of water levels. This shows that effects of pipe resistance on the surges are small, and justifies a free oscillation analysis. Free oscillation equation has six eigen modes of different periods, including a rigid mode which is existed when the pumped rate of outflow differs from the total rate of inflow. The six modes constitute a variety of surges dependent on different inflow and outflow conditions. Presence of the rigid mode needs sophisticated pump operations adjusted to real flood inflows.

  • PDF

Optimization-based calibration method for analysis of travel time in water distribution networks (상수관망 체류시간 분석을 위한 최적화 기반 검·보정 기법)

  • Yoo, Do Guen;Hong, Sungjin;Moon, Gihoon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.429-429
    • /
    • 2021
  • 2019년 발생한 인천광역시 붉은 수돗물 사태로 급수구역에 포함된 26만 1천 세대, 63만 5천 명이 직·간접적인 피해를 입은 바 있다. 경제적 피해액으로 추정할 경우 최소 1,280억 원 이상으로 보고된 바 있으며, 이와 같은 상수관망의 수질사고 확산은 장기간 동안 시민의 건강과 생활환경 수준을 저하시킨다. 따라서 상수도시스템의 수질사고확산 모델링 및 방지기술을 통한 수질안전성의 재확인이 필요하며, 이것은 상수도시스템의 지속가능성을 높여 국민이 체감하는 물 환경 수준 제고에 기여가 가능하다. 관망 내 수질해석을 직접적으로 수행하는 모델은 국외적으로 다양하게 개발(PODDS, EPANET-MSX, EPANET2.2 등)된 바 있으나 검·보정을 위한 수질측정 자료 부족 등으로 적용이 제한적이라는 한계가 현재에도 존재한다. 이를 보완하기 위해 수질자료에 비해 그 양이 많고 획득방법이 상대적으로 수월한 수리학적 계측자료 및 해석결과를 활용한 관로 내 체류시간 등을 활용한 연구가 수행된 바 있다. 그러나 이와 같은 수리학적 해석 결과를 활용하는 경우에도 계측자료를 기반으로 한 수리학적 검·보정은 필수적이라 할 수 있다. 본 연구에서는 관로 내 체류시간에 직접적인 영향을 미치는 유량 및 유속자료를 중심으로 수리학적 관망해석의 결과를 최적 검·보정하는 방법론을 제안하였다. 기존 상수관망 수리해석의 검·보정은 일부 지점에서 수압을 측정하고, 수리해석 결과로 도출되는 해당 지점의 수압이 실측된 결과와 유사하도록 관로의 유속계수를 적절히 보정하는 형태로 진행되었다. 그러나 본 연구에서는 관로유량과 유속자료의 목적함수 내 가중치를 수압자료보다 크게 설정하여 체류시간 중심의 검·보정이 수행될 수 있도록 하였으며, 검·보정 대상인자 역시 대수용가의 수요량, 수요패턴, 그리고 관로유속계수로 확장된 모형을 구축하였다. 최적화 기법으로는 메타휴리스틱 기법중 하나인 화음탐색법을 활용하였다. EPANET 2.2 Toolkit과 Visual Basic .Net을 연계하여 프로그래밍하였으며, 개발된 모형을 실제 지방상수도 시스템에 적용하여 분석하였다.

  • PDF

Detecting Multiple Leaks in Water Pipe Networks (상수관망 내 다중누수 탐지를 위한 모형 개발)

  • Choi, Jeongwook;Jeong, Gimoon;Kang, Doosun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2020.06a
    • /
    • pp.92-92
    • /
    • 2020
  • 최근 지진 발생 빈도와 규모가 증가함에 따라 지진재해에 취약한 지하구조물의 내진성능 향상 및 신속한 복구에 관한 연구가 활발히 진행되고 있다. 대표적인 지하구조물 중 하나인 상수관망은 음용수를 안전하고 원활하게 공급하는 사회기반시설물로써 대부분의 시설물이 지하에 매설되어 있어 지진재해에 매우 취약하다. 지진으로 인해 상수관망 내 누수 및 파손 등의 피해가 발생할 경우, 물 공급이 중단되어 경제적 손실과 사회 전반적인 불편이 우려되므로 피해 관로의 신속한 파악과 복구가 이루어져야 한다. 상수관로에 발생하는 피해는 크게 누수와 파손으로 구분할 수 있다. 관로가 파손된 경우 용수가 표층으로 새어나오기 때문에 탐지가 용이하지만, 누수의 경우 표층으로 드러나는 피해가 없어 탐지 및 수리가 어려운 단점이 있다. 이러한 누수가 장기간 방치될 경우, 해당 시스템의 유수율 감소로 인한 경제적인 손실과 더불어 공급수압의 저하, 그리고 오염물 침투의 위험이 존재한다. 이러한 피해를 막기 위해서는 신속히 누수 지점을 파악한 후, 피해 관로의 교체 혹은 보수가 이루어져야 한다. 현장에서 누수를 직접 탐지하는 방법은 정확도가 높은 반면, 많은 인력과 장비 그리고 비용이 소모되는 단점이 존재한다. 따라서 현장 누수탐지에 앞서 컴퓨터를 이용한 간접 누수탐지 기법이 지속적으로 개발될 필요가 있다. 본 연구에서는 현장 누수탐지의 탐지효율을 향상시키기 위해 수압, 유량 등의 관측 데이터와 수리해석 모의 및 최적화 기법을 활용한 컴퓨터 기반의 다중누수 탐지모형을 개발하였다. 개발 모형은 국내에서 운영 중인 소블럭 상수관망시스템에 적용하여 검증하고 탐지효율을 분석하였다. 컴퓨터 모의를 이용한 다중누수 탐지모형은 지진이나 홍수와 같은 대규모 재난 발생 후, 상수관망시스템의 신속한 복구 및 운영 정상화를 위한 도구로 활용될 수 있을 것으로 기대한다.

  • PDF

Sediment Transport Characteristics in a Pressure Pipeline (압력 원형관로내 유사이송특성 연구)

  • Son, Kwang Ik;Kim, Hyun Jung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.31 no.3B
    • /
    • pp.205-209
    • /
    • 2011
  • The low carrying capacity caused by the deposition in a sewer line is one of the main reason of the urban flood. Therefore, an efficient maintenance and management of the storm water drainage system is very important to prevent urban flood. In this research, the sediment transport characteristics through a pressure pipeline were examined with laboratory experiments. Bed-forms in a pipeline, sediment rates, roughness due to sediments were examined. Experimental system consists of flow circulation system with a pump and a sediment feeder at the upstream of the pipeline. Sediments were supplied into a 60 mm-diameter and 8 m-long pipe. Maximum flow rate is $30m^3/hr$, and the sediment feeding rate range is 5 g/s~19 g/s. Governing parameters and estimation equation for sediment transport rate were developed. The mean velocity (U), coefficient of viscosity (${\mu}$), unit width bed load ($q_b$), mean diameter of particle ($d_{50}$), unit weight of sediment in water (${\gamma}^{\prime}_s$) were adopted as the most influencing factors of sediment transport patterns. The prediction equation for sediment transport rate were developed with two dimensionless terms. These two dimensionless terms showed a linear relationship with high correlation coefficient.

Estimation of Structural Deterioration of Sewer using Markov Chain Model (마르코프 연쇄 모델을 이용한 하수관로의 구조적 노후도 추정)

  • Kang, Byong Jun;Yoo, Soon Yu;Zhang, Chuanli;Park, Kyoo Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.421-431
    • /
    • 2023
  • Sewer deterioration models can offer important information on prediction of future condition of the asset to decision makers in their implementing sewer pipe networks management program. In this study, Markov chain model was used to estimate sewer deterioration trend based on the historical structural condition assessment data obtained by CCTV inspection. The data used in this study were limited to Hume pipe with diameter of 450 mm and 600 mm in three sub-catchment areas in city A, which were collected by CCTV inspection projects performed in 1998-1999 and 2010-2011. As a result, it was found that sewers in sub-catchment area EM have deteriorated faster than those in other two sub-catchments. Various main defects were to generate in 29% of 450 mm sewers and 38% of 600 mm in 35 years after the installation, while serious failure in 62% of 450 mm sewers and 74% of 600 mm in 100 years after the installation in sub-catchment area EM. In sub-catchment area SN, main defects were to generate in 26% of 450 mm sewers and 35% of 600 mm in 35 years after the installation, while in sub-catchment area HK main defects were to generate in 27% of 450 mm sewers and 37% of 600 mm in 35 years after the installation. Larger sewer pipes of 600 mm were found to deteriorate faster than smaller sewer pipes of 450 mm by about 12 years. Assuming that the percentage of main defects generation could be set as 40% to estimate the life expectancy of the sewers, it was estimated as 60 years in sub-catchment area SN, 42 years in sub-catchment area EM, 59 years in sub-catchment area HK for 450 mm sewer pipes, respectively. For 600 mm sewer pipes, on the other hand, it was estimated as 43 years, 34 years, 39 years in sub-catchment areas SN, EM, and HK, respectively.