• Title/Summary/Keyword: 관로시스템

Search Result 278, Processing Time 0.032 seconds

Set up Reduction Goals of Combined Sewer Overflow Pollutant Load Using Long-Term Rainfall-Runoff Model Simulation (장기간 강우-유출 모의를 통한 합류식하수관로시스템의 월류부하량 저감목표 설정 연구)

  • Lee, Gunyoung;Na, Yongun;Ryu, Jaena;Oh, Jeill
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.11
    • /
    • pp.785-794
    • /
    • 2013
  • Combined sewer overflows during rainfall events contain sewer sediments and surface pollutants. This can cause significant chemical, physical and biological problems to receiving watershed. However, there are no method that can commonly apply to decide criteria for controlling the pollutant load. In this study, it sets up the reduction goals of combined sewer overflow through long-term simulation using the rainfall-runoff model. From a review of domestic and foreign management standard of combined sewer overflow for this, it makes decision that 60% (phase 1), 85% (phase 2) of total pollutant load and frequency per year for reduction goals is more proper. Also, the result of analyzing long-term simulation (minimum 10 years) applied to research basin indicates that reduction goals of BOD pollutant load are 1,123 kg (phase 1) and 2,374 kg (phase 2), and overflow volumes for research objective achievement are $11,685m^3$ (phase 1) and $24,701m^3$ (phase 2).

A Study on Feasibility and Applicability of Pneumatic Waste Collection System (쓰레기 수송관로 방식의 적용사례 및 실용에 관한 연구)

  • 민병균;이재영;최상일
    • Journal of Korea Soil Environment Society
    • /
    • v.2 no.1
    • /
    • pp.109-117
    • /
    • 1997
  • The dust chute was a part of equipment in apartment which have been settled down as new residential style in this country since 1960s. However, the dust chute was destructed by results of social discussion, and it ended up old remains which cannot be found in new towns. Nowadays, chute was substituted a collecting system from extra collecting sites which were prepared near residential area. This phenomenon was caused by the poor separating collection. Since the early part of 1995, the whole vocal operating the volume-base charge system has been placed as the institution capable of recycling and separating collection of residential wastes in this country. People pursue the residential quality which is suitable to the Greenround period. Such a diverse effort corresponding to the social change can be also accomplished in the field of waste collecting transportation. In this paper, the local heating system and waste combustion site and hollow are already applied to the new residential area in the form of housing development. After investigating of the waste collecting transportation method in other countries related to such facilities, this paper represents the feasibility and applicability of pneumatic waste collection system which is used practically in the new housing complex and large facilities in other countries.

  • PDF

Study on Design Capacity of Stormwater Pipe and Pumping Station considering Peak Rainfall Intensity (첨두강우강도를 고려한 우수관로 및 빗물펌프장의 설계용량 검토)

  • Chung, Gunhui;Sim, Kyu Bum;Kim, Eung Seok
    • Journal of Korea Water Resources Association
    • /
    • v.47 no.9
    • /
    • pp.777-787
    • /
    • 2014
  • Stormwater pipe systems are most commonly used to discharge rainwater from the urban catchment covered by the impervious area. To design stormwater pipe and rainwater pumping station, frequency analysis is implemented using historical rainfall and the design rainfall is timely distributed using theoretical shape such as Huff distribution. This method cannot consider the rainfall intensity variation caused by climate change which is type of uncertainty. Therefore, in this study, runoff from Gasan1 stormwater pumping stations catchment is calculated using design rainfall distributed by the 2nd quartile distribution method and the historical rainfall events. From the analysis, the nodal flooding in the urban catchment is likely caused by the high peak rainfall event rather than the large amount of rainfall. The linear regression analysis is implemented. As a result, when several storms have the same amount of rainfall, the nodal flooding in the stormwater pipe systems could be caused by the high peak of storm events. Since as the storm duration become short, the peak rainfall become high, the nodal flooding likely become severe with the short storm duration. The uncertainty in the peak data of design rainfall is analyzed and this uncertainty has to be consider in the stormwater pipe design process.

A Study on Building Sewerage Data using Dynamic Segmentation Method (Dynamic Segmentation을 이용한 오수 관거 데이터구축에 관한 연구)

  • Park, Jeong-Wo;Yun, Jeong-Mi;Lee, Sung-Ho
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.9 no.2
    • /
    • pp.11-19
    • /
    • 2006
  • Sewerage is the system that improves the quality of human life and prevents many disasters such as floods. However the investigators in Korea only have been concerned about the sewer system, so the sewage treatment plant stays in the basic level like mapping. For example, only one attribute can be recognized in the linear object. Because of this limitation, it makes difficult to manage the linear attribute regarding to the sewage pipe plan. And it is impossible to control a partial (point type, line type) attribute changes of the linear object. We will therefore present the applicable method for the attribute changes of the linear object like the sewage pipe plans. For this reason, this paper is designed on the basis of Dynamic Segmentation(DS). DS has the advantage of giving the attribute value to the exact place in the linear object. As a result of using DS, the variety environment changes around the sewage pipes are applied to the building sewerage data. This also makes it possible to get a precise estimation for the maximum dirty water amount.

  • PDF

Fundamental Experiment for the Development of Water Pipeline Locator (상수도관로 위치탐사 장비개발을 위한 기초실험)

  • Park, Sang-Bong;Kim, Jin-Won;Oh, Kyeong-Seok;Kim, Min-Cheol;Koo, Ja-yong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.30 no.3
    • /
    • pp.253-261
    • /
    • 2016
  • A variety of methods for detecting the location of an underground water pipeline are being used across the world; the current main methods used in South Korea, however, have the problems of low precision and efficiency and the limitations in actual application. On this, this study developed locator capable of detecting the location of a water pipe by the use of an IMU sensor, and technology for using the extended karman filter to correct error in location detection and to plot the location on the coordinate system. This study carried out a tract test and a road test as basic experiments to measure the performance of the developed technology and equipment. As a result of the straight line, circular and ellipse track tests, the 1750 IMU sensor showed the average error of 0.08-0.11%; and thus it was found that the developed locator can detect a location precisely. As a result of the 859.6-m road test, it was found that the error was 0.31 m in case the moving rate of the sensor was 0.3-0.6 m/s; and thus it was judged that the equipment developed by this study can be applied to long-distance water pipes of over 1 km sufficiently. It is planned to evaluate its field applicability in the future through an actual pipe network pilot test, and it is expected that locator capable of detecting the location of a water pipe more precisely will be developed through research for the enhancement of accuracy in the algorithm of location detection.

Hydraulic consideration to improve the tractive force of sewage in sewer pipes using a storage tank (관로내 하수흐름의 전단응력 향상을 위한 저수조의 활용에 관한 수리적 고찰)

  • Park, Kyoohong;Yu, Soonyu;Lee, Taehoon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.2
    • /
    • pp.121-129
    • /
    • 2019
  • If sewage flows for an extended time at low velocities, solids may be deposited in the sewer. Sufficient velocity or tractive force should be developed regularly to flush out any solids that may have been deposited during low flow periods. This study aims to evaluate the periods (T) during which sewage flow greater than the minimum tractive force maintains on a spot in sewer pipe system with lower tractive force or lower velocity than expected in the design step, when a storage tank installed in a place upsteam pours water into the sewer. The effect to T of design factors of storage tank and sewer pipes was evaluated assuming the uniform flow in sewers. When the area of orifice in the storage tank is $0.062m^2$(or 0.28 m diameter), the maximum T of 31sec was maintained using the usually used preset range of values of several design factors. As the horizontal cross section of storage tank and water depth of storage tank and roughness in sewers increase, T linearly increases. Also, T linearly decreases as the diameter of a sewer pipe increases. Although T gradually decreases as the sewer pipe slope decreases to around 0.005, T decreases sharply when the slope is less than 0.003.

A Study on Valve-Induced Water Hammer Characteristics for Large Pump System (밸브에 의한 대형펌프시스템의 수격특성에 관한 연구)

  • Lee, C.J.;Lim, K.S.;Cho, D.H.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2009.06a
    • /
    • pp.177-178
    • /
    • 2009
  • Hydraulic Transients would be occurred since pressure is increased or decreased when water speed inside of pipeline is rapidly changed A study on water hammer has become more important because the pumping stations were big and the systems conveying the fluid through the large and long transmission pipelines were complex. In this study, the method of characteristic line was adopted to evaluate the valve-induced water hammer phenomena in a pumps feedwater system.

  • PDF

Development of an Application System for Efficient Management of Underground Water Supply Facility - Pilot Study in Chonju City - (상수도 지하시설물의 효율적 관리를 위한 응용시스템 개발 -전주시를 대상으로-)

  • 오권호;진철하;이근상;정승현;조기성
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.18 no.2
    • /
    • pp.111-120
    • /
    • 2000
  • Water, waste, electric and gas facilities are urban based facilities that needed in our life and are often located in underground. Therefore, underground facilities are more difficult to manage efficiently than ground facilities. It is needed to carry out survey/probe into underground facilities and to build database in order to prevent city-misfortunes being occurred because of negligent management and in order to minimize budget-waste and a traffic jam according to repetition of road excavation constructions. Also, the development of application system is required to manage efficiently underground facility. Chonju city has launched underground water supply facility computerizing project as a part of National Geographic Information System project until December 1998 and executed survey/probe into 402.89 km water supply that is 80 mm up inside central town area 39.6 $km^2$. Also, chonju city built database into 537 km water supply that is 80 mm below based on water supply card without other survey/probe works. Also, existing work process each department is changed into GIS applied work process and underground water supply facility management system is developed by its work process basis. Water supply underground facility management system that is developed is composed of sub-system like base-map management, water supply inspect, water supply management and water supply inquiry, construction work management, administration management and map management. This research presents the procedure and method of underground water supply facility survey/probe and problem being occurred during survey/probe procedure and also show the functions of each sub-systems composing underground water supply facility management system.

  • PDF

Improvement and Operation of Urban Inundation Forecasting System in Seoul (서울시 도시침수 예측시스템의 개선 및 운영)

  • Shim, Jea Bum;Kim, Ho Soung;Gang, Tae hun;Lee, Byong Ju
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2021.06a
    • /
    • pp.481-481
    • /
    • 2021
  • 서울시는 '10년, '11년, '18년의 기록적인 호우로 인해 막대한 재산피해를 기록하였다. 이로 인해 서울시는 수재해 최소화 대책의 필요성을 인지하여 방재시설물 확충 등의 구조적 대책과 함께 침수지역 예측, 호우 영향 예보와 관련된 비구조적 대책 수립을 위해 노력하고 있다. 그 일환으로 2018~2019년 『서울시 강한 비구름 유입경로 및 침수위험도 예측 용역』 수행을 통해 레이더 실황강우 기반의 강한 비구름 이동경로 추정 기술, 강우시나리오 기반의 침수위험지역추정 기술이 적용된 서울시 도시침수 예측시스템을 개발하였다. 또한, 침수피해에 선제적으로 대응하기 위해 2019~2020년 『서울시 내수침수 위험지역 실시간 예측기술 개발』을 통하여 이류모델 기반의 예측강우정보 추정 기술, 예측강우정보 기반의 실시간 침수위험지역 추정기술을 적용하였다. 현재 서울시 도시침수 예측시스템은 서울시 전역의 강우 및 침수정보를 제공하며, 관로 113,286개(전체 385,768개), 맨홀 106,097개(전체 272,133개), 빗물펌프장 117개소(전체 121개소)가 반영되어 있다. 서울시 도시침수 예측시스템에서는 서울시 25개 자치구를 대상으로 실황 및 예측 강우정보, 강한 비구름에 대한 이동경로정보, 시나리오 및 실시간 침수정보를 제공하고 있다. 강우정보는 10분 및 1시간 단위 AWS 실황정보와 10분 단위 이류모델 기반 예측정보, 1시간 단위 LDAPS 기반 예측정보를 제공한다. 또한, 레이더 실황정보를 통해 판별된 강한 비구름에 대해 10분 단위 1시간 예측경로를 제공한다. 침수정보는 총강우량, 강우지속기간, 빗물받이효율 조건을 반영한 강우시나리오 기반의 6m 고해상도 격자단위 침수시나리오 정보와 자치구별 침수위험정보를 제공한다. 또한, 이류모델 기반의 레이더 예측정보를 이용하여 실시간 침수 예측정보를 제공한다. 향후 서울시 내 모든 수방시설물의 적용, 관로 유출구별 기점수위 반영, 관측자료를 이용한 도시유출 및 도시침수 모델 최적화 등 지속적으로 고도화를 수행하고자 하며, 서울시 도시침수 예측시스템을 통해 서울시 및 자치구 풍수해 담당자가 침수피해를 대비, 대응할 수 있을 것으로 기대된다.

  • PDF

Urban Runoff Management System Using Ubiquitous Floater (Ubiquitous Floater를 이용한 도시 배수 관리 시스템)

  • Yi, Jae-Eung;Choi, Chang-Won
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.603-607
    • /
    • 2008
  • 최근 이상기후현상으로 인한 가뭄과 홍수의 빈번한 발생으로 인해 인명 및 재산피해가 증대되고 있다. 특히 도시지역에서의 홍수 피해가 심각한 상황이다. 도시지역에서는 불투수 면적의 증가로 우수 유출량의 대부분을 배수관망에 의존하고 있다. 그럼에도 불구하고 현재 배수관거에 대한 관리는 미흡한 실정으로 노후되거나 부실한 배수관을 통해 토양으로 누수되거나, 관로 내에 누적된 퇴적물로 인한 관경의 축소 등으로 인해 우수가 원활하게 배제되지 못하고 지체되면서 인근지역의 침수피해를 증가시키고 있다. 이러한 피해를 경감시키기 위해서 지속적이고 신뢰성 있는 배수관 내 유황자료의 획득이 시급한 상황이다. 그러나 현재 수집되고 있는 도시지역의 배수 자료는 하천유황자료에 편중되어있으며, 배수관망 자료는 배수관망 내 유황자료의 획득이 어렵고, 배수관망 내에서 흐름의 경로 파악이 불가능 하다는 문제점을 가지고 있다. 본 연구에서는 도시 배수관망에 대한 지리정보시스템의 자료와 ubiquitous floater로부터 획득한 유황자료를 결합하여 도시 배수 관리 시스템을 구축하는 것에 목적을 두었다. 도시 배수 관리 시스템에서는 bluetooth 무선통신 기술을 이용한 ubiquitous floater를 사용하여 배수관망 내의 유속과 흐름 경로를 측정하고, 측정된 실시간 수문자료는 CDMA 무선통신모듈을 이용하여 server 컴퓨터에 전송된다. 수집된 자료는 대상유역의 지리정보시스템의 자료와 결합하여 도시 배수 관리 시스템으로 구축된다. 도시 배수 관리 시스템은 관리자가 배수관의 특성을 파악하고 문제발생시 신속하게 조치할 수 있게 도움을 줄 수 있으며, 전문적인 지식이 없는 누구나(whoever), 언제(whenever), 어디서(wherever)든 PC 앞에서 원거리에 위치한 도시 배수관망 내의 흐름 경로를 파악하고 관망 내 흐름의 현황을 파악할 수 있다.

  • PDF