A scheme of leak detection model in a reservoir pipeline valve system using wavelet coherence analysis of injected pressure wave (주입 압력파의 웨이블릿 일관성 분석을 사용한 저수조-관로-밸브 시스템에서의 누수탐지모형 연구)

  • Ko, Dongwon;Lee, Jeongseop;Kim, Jinwon;Kim, Sanghyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.1
    • /
    • pp.15-25
    • /
    • 2021
  • In this study, a method of leakage detection was proposed to locate leak position for a reservoir pipeline valve system using wavelet coherence analysis for an injected pressure wave. An unsteady flow analyzer handled nonlinear valve maneuver and corresponding experimental result were compared. Time series of pressure head were analyzed through wavelet coherence analysis both for no leak and leak conditions. The leak information can be obtained through either time domain reflectometry or the difference in wavelet coherence level, which provide predictions in terms of leak location. The reconstructed pressure signal facilitates the identification of leak presence comparing with existing wavelet coherence analysis.

급수관로에서의 역류발생 원인과 방지대책

  • 김영호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.30 no.3
    • /
    • pp.43-51
    • /
    • 2001
  • 본고는 수도직결식 급수시스템에 초점을 두어 역류에 대한 실제를 다룬 것이나, 그 내용은 모든 급수방식에 적용되는 것이다.

  • PDF

Corrosion Characteristics by CCPP Control in Simulated Distribution System (CCPP 조절에 따른 모의 상수관로의 부식특성에 관한 연구)

  • Kim, Do-Hwan;Lee, Jae-In;Lee, Ji-Hyung;Han, Dong-Yueb;Kim, Dong-Youn;Hong, Soon-Heon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1249-1256
    • /
    • 2005
  • This study was performed to investigate the efficiency of the corrosion prevention in the simulated distribution system using CCPP(Calcium Carbonate Precipitation Potential) as the anti-corrosive index by adjusting pH, total dissolved solids, alkalinity and calcium hardness in the water treatment pilot process. The materials of the simulated distribution system(SDS) were equiped with same materials of real field water distribution system. CCPP concentrations controlled by $Ca(OH)_2$, $CO_2$ gas and $Na_2CO_3$ in the simulated distribution system and uncontrolled by the chemicals in the general water distribution system were average 0.61 mg/L and -7.77 mg/L. The concentrations of heavy metals like Fe, Zn, Cu ions in effluent water of the simulated distribution system controlled with water quality were decreased rather than the general water distribution system uncontrolled with water quality. In simulated distribution system(SDS), corrosion prevention film formed by CCPP control was observed that scale was come into forming six months later and it was formed into density as time goes on. We were analyzed XRD(X-ray diffraction) for investigating component of crystal compounds and structure for galvanized steel pipe(15 mm). Finding on analysis, scale was compounded to $Zn_4CO_3(OH)_6{\cdot}H_2O$ (Zinc Carbonate Hydroxide Hydrate) after ten months late, and it was compounded on $CaCO_3$(Calcium Carbonate) and $ZnCO_3$(Smithsonite) after nineteen months later.

The Effects of pH and Alkalinity Adjustment on Internal Corrosion Control and Water Quality in Drinking Water Pipelines (정수의 pH 및 알칼리도 동시 조절이 상수도관의 내부부식 제어 및 수질에 미치는 영향)

  • Lee, Hyun-Dong;Jung, Hae-Ryong;Kwak, Phill-Jae;Chung, Won-Sik
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.4
    • /
    • pp.661-669
    • /
    • 2000
  • This research was carried out to evaluate effect of metallic release and change of water corrosive indices by the pH and alkalinity adjustment using the SDLS (Simulated Distribution Loop System) which consist of six types of pipe loop with DCIP, PVC, PE, STS304, CP, GSP, respectively, and its effects on water quality changes which were microbes quality(SPC), residual chlorine. THMs and other parameters. And it was to propose optimal criteria of water quality control for the field application. According to the results, water control system by pH and alkalinity adjustment showed the changing of corrosive water and reducing of metallic release rate and it was not affects of THMs formation, microbes regrowth and variation of other parameters. Water quality stability and corrosion control were due to calcium carbonate precipitation film formation of pipe inner by water quality control. Therefore, corrosive water control system by pH and alkalinity adjustment can be attributed to effective water quality management in water distribution system according to water quality stability of pH and TIC(Total Inorganic Carbonate concentration) that affect the precipitation and dissolution of solids.

  • PDF

Development and Verification of Inundation Model Considering Storm Sewers in Urban Area (도시배수체계와 연계한 침수모형의 개발 및 검증)

  • Han, Kun-Yeun;Lee, Chang-Hee;Kim, Ji-Sung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.159-162
    • /
    • 2005
  • Urban flooding is usually caused by the surcharge of storm sewers. For that reason, domestic studies about urban flooding are concentrated on the simulation of urban drainage system. However these approaches that find the pipes which have insufficient drainage capacity are very approximate and unreasonable ways. In this study, an accurate mathematical modeling is developed to analyze the impacts of an urban inundation for both flood prevention and flood-loss reduction planning and it is verified by using the simulation of July 2001 flooding in Seoul. The result of this study can be used to construct fundamental data for a flood control plan and establish a urban flood forecasting/warning system.

  • PDF

Optimal Design of Storm Sewer by Computations of Feasible Hydraulic Gradient Line (합리적 동수위 계산을 통한 최적 배수관로 설계)

  • Yoo, Hee-Sang;Kim, Mun-Mo;Ahn, Won-Sik
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.1585-1589
    • /
    • 2009
  • 최근 빈발하는 국지성 호우나 태풍에 의한 집중호우로 도시지역의 내배수불량으로 인하여 저지대 및 지하공간의 침수현상이 빈번히 야기하고 있는 실정이다. 특히 연안이나 외수위의 영향으로 강제배수가 요구되는 지역인 경우에는 개발에 앞서 선결해야할 중요한 재해저감대책 중의 하나이다. 이에 본 연구에서는 연안의 해수면 및 하천 홍수위로 인한 계획단지 내 배수관로의 동수위 산정을 위한 유출모의를 수행하였다. 연안저지대의 순성토 지역인 경우 동수위 계산에 따른 성토량에 의한 비용이 전체 공사비 결정 요인의 가장 큰 부분을 차지하고 있으므로 이에 따른 경제적이면서 치수안전도를 증가시킬 수 있는 계산 방법을 정립하는 것은 선결되어야 할 문제이다. 이를 위해 도시유역에 범용적으로 사용되고 있는 SWMM 모형을 활용하였다. SWMM 모형 중에서 EXTRAN 블록을 통한 유출모의는 관거내 동수경사를 계산하여 배수, 역류, 압력류, 월류까지도 모의할 수 있다. 다양한 조건으로 배수관로의 설계를 통한 동수위와 성토고를 분석하여 조건별 경제성과 치수안전도를 검토할 수 있으나 관로 크기, 경사, 방향 등을 우선하여 변경해가면서 최적안을 확인하였다. 검토된 계산 절차에 따라서 향후 지형적으로 유사한 지역에서의 배수시스템 설계에 적용 및 기존 배수관망 재설계 및 확장 등의 검토에 효과적으로 적용할 수 있을 것이다.

  • PDF

Experimental Investigation on Behavior of Single Horizontal Buoyant Jet (단일수평부력제트의 거동에 관한 실험적 연구)

  • Seo, Il-Won;Kim, Ho-Jung;Kwon, Seok-Jae
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.1011-1015
    • /
    • 2005
  • 본 실험에서는 부력 조건이 달라질 때 단공방류구에서 정체수역으로 수평방류되는 부력제트의 거동을 규명하였다. LIF (Laser Induced Fluorescence) 시스템을 이용하여 수행하였는데, LIF 시스템은 고해상도의 이미지를 취득할 수 있어 데이터의 정확도가 높으며, 동시에 한 평면상의 농도장을 일시에 측정할 수 있는 장점이 있는 기술이다. LIF 시스템은 크게 세부분으로 구성되어 있는데 방출시스템, 포착시스템, 처리시스템이 그것이다. 실험 조건을 고려해서 온수를 이용하여 주변수와의 밀도차를 재현하였으며, LIF 시스템의 추적입자로 형광염료 Rhodamine B를 사용하였다. 또한, 실험 데이터 취득과정에서 필요한 검정과정을 수행하였는데, LIF 시스템에서 검정과정은 레이저 입사광의 강도가 불균등한 분포를 가지는 점과 주변수의 매질에 의한 근의 감쇠가 발생하는 문제를 해결하기 위한 것이다. LIF 시스템은 부력제트의 농도장을 매우 정밀하게 측정할 수 있는데, 방류밀도 Froude 수가 변함에 따라 측정된 순간이미지를 통해 제트의 진화과정을 상세하고 가시적으로 확인할 수 있었다. 검정과정을 거친 농도 종단면에서 중심선의 연장선이 LIF 시스템에 의해 측정된 순간이미지의 중심선 궤적과 거의 일치하는 것도 알 수 있었다. 또한 LIF 시스템을 통해서 취득된 단일수평부력제트의 궤적과 중심선 희석률을 기존의 상용모형인 VISJET과 CORMIX1에 의해 예측된 결과와 비교$\cdot$분석한 결과, 제트 중심선 궤적의 경우, LIF 시스템을 이용한 측정값은 대체로 VISJET 모형의 결과와 일치하는 것으로 밝혀졌다. 중심선 희석률의 경우, LIF 측정값은 대체로 CORMIX1 모형, Cederwall(1968)의 경험식과 일치하는 경향을 보였다.0\%$일 때가 밸브를 $60\%$$80\%$ 개폐시켰을 때보다 $0.3kg/cm^2,\;0.29kg/cm^2$ 낮게 나타나 밸브를 전체 개방 했을 때 관로내의 수압이 상수설계기준에 적합한 수압을 유지함을 알 수 있다. 상수관로 설계 기준에서는 관로내 수압을 $1.5\~4.0kg/cm^2$으로 나타내고 있는데 $6kg/cm^2$보다 과수압을 나타내는 경우가 $100\%$로 밸브를 개방하였을 때보다 $60\%,\;80\%$ 개방하였을 때가 더 빈번히 발생하고 있으므로 대상지역의 밸브 개폐는 $100\%$ 개방하는 것이 선계기준에 적합한 것으로 나타났다. 밸브 개폐에 따른 수압 변화를 모의한 결과 밸브 개폐도를 적절히 유지하여 필요수량의 확보 및 누수방지대책에 활용할 수 있을 것으로 판단된다.8R(mm)(r^2=0.84)$로 지수적으로 증가하는 경향을 나타내었다. 유거수량은 토성별로 양토를 1.0으로 기준할 때 사양토가 0.86으로 가장 작았고, 식양토 1.09, 식토 1.15로 평가되어 침투수에 비해 토성별 차이가 크게 나타났다. 이는 토성이 세립질일 수록 유거수의 저항이 작기 때문으로 생각된다. 경사에 따라서는 경사도가 증가할수록 증가하였으며 $10\% 경사일 때를 기준으로 $Ro(mm)=Ro_{10}{\times}0.797{\times}e^{-0.021s(\%)}$로 나타났다.천성 승모판 폐쇄 부전등을 초래하는 심각한 선천성 심질환이다. 그러나 진단 즉시 직접 좌관상동맥-대동맥 이식술로 수술적 교정을 해줌으로써 좋은 성적을 기대할 수 있음을 보여주었다.특히

  • PDF

A Case Study on Cost-Benefit Analysis of the Septic Tank and Exclusive Sewage Pipe Line in Designing the large Building at Combined Sewer District (합류식 하수도 지역에 대형 건축물 설계시 정화조 및 전용오수관로의 비용편익분석 사례연구)

  • Oh, Hyun-Taek;Kim, Sung-Tai;Lim, Byung-In;Kang, Byong-Jun;Park, Kyoo-Hong
    • Journal of Digital Convergence
    • /
    • v.17 no.6
    • /
    • pp.169-175
    • /
    • 2019
  • The aim of this study is to examine the relative economic benefits between the septic tank and exclusive sewage pipe line in designing the large building at combined sewer districts. With the case study of Lotte World Tower Building, we analyze a cost-benefit between two alternatives. The research results showed 2 years of payback period, about ₩6.17 billion of NPV, and 1.93 of B/C ratio for installing the exclusive sewage pipe line in comparison with septic tank. This results provide useful guidelines for policy establishment of the septic tank closure and for plausibility of installing exclusive sewage pipe line when constructing a large building. In the future, it will be necessary to consider additional cost-benefit analysis including burden charge borne by causers, the burden of management responsibility with a exclusive sewage pipe line, and the economic benefits of reducing odor.