• Title/Summary/Keyword: 관내유동

Search Result 243, Processing Time 0.021 seconds

An Experimental Study on the Flow-rate and Velocity Profile of Air Flow in the Smooth Pipe (매끈한 관내 공기유동에서 유량과 속도분포에 관한 실험적 연구)

  • Park, Sang-Eun
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.4 s.17
    • /
    • pp.54-60
    • /
    • 2002
  • Experimental study was conducted to obtain the air velocity profiles in turbulent pipe flow. The acrylic smooth pipe (${\phi}=80mm$) was used for the test section of the flow loop. It was known that the velocity profiles of turbulent flow were different with Reynolds numbers and the viscous sublayer was usually quite thin. The following conclusions were drawn from the experimental investigations. Maximum velocity of the pipe center and flow-rate are useful for the duct design on the spot. The velocity profiles of high Reynolds number was flatter than those of low Reynolds number. It was known that the exponent, n, for power-law velocity profiles was $6{\sim}9$ depending on Reynolds number ranging from $10^4$ to $10^5$ in the turbulent flow, However, in this experiment study, it was $9{\sim}14$ depending on Reynolds number ranging from 17,000 to 123,727 in the turbulent flow, and $1.7{\sim}3.5$ depending on Reynolds number ranging from 2,442 to 4,564 in the transition region.

Heat Transfer Performance of Pond loop type Heat Exchanger for Ground Source Heat Pump using Extruding Ground Wafer (유출지하수 열원 지열히트펌프용 Pond Loop형 열교환기의 열전달 성능)

  • Park Geun-Woo;Kim Jin-Sang;Lee Eung-Youl
    • New & Renewable Energy
    • /
    • v.2 no.2 s.6
    • /
    • pp.86-93
    • /
    • 2006
  • 유출지하수나 지표수를 열원으로 지열히트펌프의 지초자료로 활용하기 위하여 Pond Loop형 열교환기를 설계, 제작하여 유동이 없는 수조 내에서 수조의 온도가 변화함에 따라 일정한 열교환기 입구온도를 유지하면서 열전달량을 측정하였다. 그 결과 수조를 Heat Source로 사용하는 경우 $5,500{\sim}4,500kcal/h$의 열량이 전달되었고 수조를 Heat Sink로 사용할 경우 $5,200{\sim}3,500kcal/h$의 열량이 전달되었다. 또한 열교환기 관내 유속이 증가함에 따라 열전달량이 증가하는 경향성을 확인할 수 있었고 이는 동시에 열교환기 입출구의 차압을 증가시킴을 알 수 있었다. 열교환기의 설계단계에서 사용하였던 열전달관계식으로 구한 총괄열전달계수, U와 실험값을 통해 유추한 U값을 비교한 결과 실험에 의해 유추된 U값이 $24{\sim}27%$ 설계치보다 크게 나타났다. 본 연구를 통하여 유출지하수 뿐만 아니라 하수 및 하천수를 이용한 지열히트펌프의 기초자료를 확보할 수 있었다.

  • PDF

Simulation and Analysis of a Gas Pipeline Network in Kyungin Area using Statistical Approach (경인지역 가스 수송을 위한 배관망시스템의 모사 및 분석)

  • Lee Eun-Lyong;Chang Seung-Yong;Kim In-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.14-20
    • /
    • 1997
  • Pipeline network analysis requires fluid mechanics. A lot of equations have been used for flow analysis according to the behavior of fluid in pipelines and the operative situations. In this paper, simulation and analysis have been performed for the pipeline network system in Kyungin area using a steady-state mathematical model. Then, a statistical model using partial least squares(PLS) method has been developed with the data obtained from the developed mathematical model. The results showed that it is possible to simulate and analyze pipeline network systems using statistical approach.

  • PDF

Ice-formation phenomena for laminar water flow in a stenotic tube (협착관내 층류유동에서 물의 결빙현상)

  • 서정세;김무근;노승탁;임장순
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.1
    • /
    • pp.11-21
    • /
    • 1998
  • A numerical study is made on the ice-formation for water flow inside a stenotic tube. The study takes into account the interaction existing between the laminar flow and the stenotic port in the circular tube. In the solution strategy, the present study is substantially distinguished from the existing works In that the complete set of governing equations in both the solid and liquid regions are resolved. In a channel flow between parallel plates, the agreement of predictions and available experimental data is very good. Numerical results are mainly obtained by varying the height and length of a stenotic shape and additionally for several temperatures of the wall and inlet of tube. The results show that the shape of stenotic port has the great effect on the thickness of the solidification layer in the tube. As the height of a stenosis grows and the length of a stenosis decreases, the ice layer thickness near the stenotic port is thinner due to backward flow caused by the sudden expansion of water tunnel. It is also found that the ice layer becomes more fat In accordance with Reynolds number and the temperature of the wall and inlet of tube decreased.

  • PDF

A Study on the Flow Characteristics in the Stenosed Tube of the Non-Newtonian Fluids (비뉴튼유체의 협착관내 유동 특성에 관한 연구)

  • Park, S.A.;Yoon, J.B.;Yoo, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.4 no.4
    • /
    • pp.342-350
    • /
    • 1992
  • An experimental investigation of the stenosis effects on the pressure drop and flow change in the internal flow is presented. Stainless steel tubes of small diameter(3.175mm, 3.4mm) are used for the test section of the flow loop. Percent contraction ranges from 35% to 83% and the stenosis length ratio (L/d) is varied from 2.8 to 8. Water and aqueous glycerol solutions are used for Newtonian fluids and polymer solutions of Separan AP-273 (500 wppm, 1000 wppm) for non-Newtonian fluids. Pressure loss coefficients of non-Newtonian fluids decrease just as those of Newtonian fluids. The loss coefficients of Newtonian and non-Newtonian fluids increase as the percent contraction increases and the loss coefficients of non-Newtonian fluids are larger than those of Newtonian fluids for the same stenosed tube. The loss coefficient increases as the stenosis length ratio increases.

  • PDF

Flow Characteristics in an Adiabatic Capillary Tube of Carbon Dioxide ($CO_2$ 단열 모세관내 유동 특성)

  • Roh, Geon-Sang;Son, Chang-Hyo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.19 no.6
    • /
    • pp.537-544
    • /
    • 2008
  • In this paper, flow characteristics of an adiabatic capillary tube in a transcritical $CO_2$ have been investigated employing the homogeneous model. The model is based on fundamental equations of mass, energy and momentum which are solved simultaneously. Two friction factors(Churchill) and viscosity(McAdams) are comparatively used to investigate the flow characteristics. Supercritical and subcritical thermodynamic and transport properties of $CO_2$ are calculated employing EES property code. Flow characteristics analysis of $CO_2$ adiabatic capillary tube is presented to offer the basic design data for the operating parameters. The operating parameters considered in this study include inlet temperature and pressure of an adiabatic capillary tube, evaporating temperature and inner diameter tube. The main results were summarized as follows : inlet temperature and pressure of an adiabatic capillary tube, evaporating temperature, mass flowrate and inner diameter of $CO_2$ adiabatic capillary tube have an effect on length of an adiabatic capillary tube.

A Study On Heat Transfer and Flow Characteristics for Boring in Sewer by Rotating Cutter Tool (회전노즐장비 작동시 하수관내의 열전달 및 유동현상에 관한 연구)

  • Park Young-Ki;Lee Jang-Choon;Lee Dong-Joo
    • Journal of Environmental Science International
    • /
    • v.15 no.1
    • /
    • pp.95-100
    • /
    • 2006
  • Heat transfer and flow characteristics in a pipe in which the rotating cutting tool for boring a underground pipe without digging were considered in this study. The amount of heat generation due to the friction between the rotating cutter and pipe wall, mixing (low of air and water injected to cool down are the two important factors to design the boring machine Computational fluid dynamics analysis using the Eulerian mixture model and the standard $\kappa-\varepsilon$ turbulence model was used to analyze the complex phenomena in a pipe during the process. Results show that pipe wall temperature decreased with increasing the cooling water inlet velocity. it is also shown that pipe wail temperature was lowered when the cutter rotation speed was increased until 600 rpm. There was no further cooling effect over 600 rpm.

Design and Numerical Analysis of Swirl Generator in Internal Duct using Delta Wing with Vortex Flap (와동 플랩 삼각날개를 이용한 관내 와류 발생장치 설계 및 수치해석)

  • Kim, Myung-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.9
    • /
    • pp.761-770
    • /
    • 2007
  • In this study, a swirl generator using delta wing was developed in order to simulate total pressure distortion and flow angle distortion. The delta wing was used for $65^{\circ}$-degree sweep back angle to satisfy the design performance for vortex core position, total pressure distortion(DC90) and swirl angle. To extend the swirling flow area, a $45^{\circ}$-degree vortex flap have applied to the delta wing. The swirl generator satisfied the design requirement of distortion coefficient in the flow distortion test to be applied to the simulation duct, and the performances of distortion for vortex core position and swirl angle using CFD(computational fluid dynamics) analysis results that was verified by flow distortion test results.

A Study on Flow Characteristics with Ultrasonic Forcing in a Coaxial Circular Pipe by PIV Measurement (동심원관내에서 초음파가 가진된 유동특성의 PIV계측에 의한 연구)

  • Koo, J.H.;Park, Y.H.;Choi, W.C.;Song, M.G.;Ju, E.S.
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.639-644
    • /
    • 2000
  • An experiment on the enhancement of turbulent flow with ultrasonic forcing was carried out by using PIV measurement in a coaxial circular pipe which could offer characteristics of the turbulence flow plentifully through its jet. A large transparent acryl tank and a coaxial circular pipe nozzle were made for the above research. city water of $25^{\circ}C$ was selected as an experimental liquid and the front flow field of the coaxial circular pipe was divided vertically as 3 measuring regions to observe characteristics of flow phenomena. characteristics of fluid flow such as velocity vector distribution, kinetic energy, turbulent intensity and etc. were visualized, observed, examined and considered at 5 kinds of Re No. such as $Re=1{\times}10^3,\;2{\times}10^3,\;3{\times}10^3,\;5{\times}10^3,\;1{\times}10^4$. In result it was proved that ultrasonic vibration affected the enhancement of turbulent flow.

  • PDF

The Thermal and Flow Analysis in the Channel of Plate Heat Exchanger with Crossed-Discrete Ribs (직교하는 단락형 리브를 부착한 판형 열교환기 관내측 열유동 해석)

  • Lee, Kwan-Soo;Moon, Hyoung-Kyu;Chung, Kilyoan
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.5
    • /
    • pp.678-686
    • /
    • 1999
  • The purpose of this work is to Investigate the pressure drop and the heat transfer characteristics in the channel of plate heat exchanger with crossed-discrete ribs. The flow is assumed to be three-dimensional, laminar and periodically fully developed. Computations have been carried out for angles of attack from $0^{\circ}$ to $90^{\circ}$ and ratios of rib height from 0.15 to 0.46 for various values of Reynolds and Prandtl numbers. The heat transfer was improved by inclined ribs generating helical vortices and secondary flows. The results show that the pressure drop has a maximum value at $70^{\circ}$ and the heat transfer has a maximum value at $45^{\circ}$. As the rib height increases, the pressure drop and the heat transfer increase quadratically, and the increasing rate of pressure drop is higher than that of the heat transfer. As Reynolds number increases, the pressure drop increases in proportion to the square of Reynolds number and the heat transfer increases linearly.