• Title/Summary/Keyword: 관경

Search Result 138, Processing Time 0.022 seconds

The Comparison Analysis of Welding Techniques in Water Distribution Steel Pipes (상수도강관 용접접합의 방법별 비교분석)

  • Kim, Eung-Seok;Jeong, Won-Sik;Kim, Sung-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2859-2865
    • /
    • 2011
  • The welded connection is known as an essential factor for establishing qualified construction and/or maintenance of wrapped steel pipe. In this study, welded connection conditions in the coated pipes with large diameter (over 700 mm) in Korea water distribution systems were estimated for suggesting technically and economically available welded connection method. For the study analysis, current steel pipe usage and accident cases were investigated. In addition, the characteristics of each welded connection method and automatic or manual connection techniques were also compared and estimated. As results, automatic welded connection method is superior than manual welded connection method in aspect of pure construction cost (average 9%) or pure welded connection cost (average 13.5%). When the poor welding-working situations in Korea are considered such as high tolerance of out-of-roundness in KS regulation, a number of lap joint welded connections, the real cost benefits of automatic welded connection should be much higher than those of manual welded connections.

Analysis of Rainfall-Runoff Characteristics by Improvements to the Roughness Coefficient in a Storm Sewer System (우수관거 조도계수 개선에 따른 강우-유출 특성 분석)

  • Kim, Eung-Seok;Jo, Deok-Jun;Yoon, Ki-Yong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.282-286
    • /
    • 2017
  • Rapid industrialization and urbanization have resulted in an increase in impervious areas and an increase in runoff, therefore, this causes more flooding and damage in urban areas. This study has analyzed the effects of improvements to the roughness coefficient in storm sewer pipes on flood runoff and outflow through rainfall-runoff simulations. The simulations are implemented by three scenarios to evaluate effects of improvements to the roughness coefficient for the improved length ratio to the total length, diameters and mainlines of sewer pipes. The size and length of the sewer mains are large and long to effectively increase the flow rate to the outlet, secure the passage discharge capacity of the pipe and reduce the overflow. It is effective for flood reduction that the improvement to roughness coefficient is first conducted in mainlines with longer lengths and larger diameters. The results from this study can provide a guideline for prioritizing of the sewer pipe replacement.

An Experimental Study on the Application Method of Infiltration Trench (침투트렌치 적용방안에 관한 실험적 연구)

  • Jung, Do-Joon;Ahn, Seung-Sub;Kim, Yun-Tae
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.6
    • /
    • pp.147-154
    • /
    • 2010
  • In this study, flood control effects for infiltration trench which is one of runoff reduction facilities were analyzed based on hydraulic experiments. Hydraulic experiments were conducted using 25 cm diameter circular pipe, and water depths for boundary conditions are 5, 10, 15, 20, 25 cm. Infiltration volume, runoff volume, runoff initiation time, final infiltration capacity and final infiltration capacity reached time etc. were measured from infiltration trench hydraulic experiment. We assumed that drainage area of each infiltration trench is $130\;m^2$ ($6.5\;m{\times}20\;m$) and calculated CN with area based on those experimental characteristics. In AMC-I condition, the calculated CN with five water depths is 84 for 2% pipe slope, 83 for 5% pipe slope. In AMC-III condition, the calculated CN is 84 for 2% and 5% pipe slope.

Ocean Outfall과 폐수처리 공정의 비용분석을 이용한 수영만의 수질관리

  • Park, Hae-Sik;Park, Cheong-Gil;Lee, Seok-Mo
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 1997.10a
    • /
    • pp.52-53
    • /
    • 1997
  • 수역의 유기오염 개선을 위하여 생활하수, 산업폐수 등의 저하시키는데 주안점을 두어왔으나 공공수역에서의 제거되지 않은 질소와 인의 유입으로 부영양화가 진행되어 하천에는 남조류가 대량발생하고 해역에는 적조가 광역에서 발생하여 큰 사회문제가 되고 있고, 질소와 인의 유입으로 인한 자생 COD가 전체COD의 약 절반을 차지하고 있는 실정이다. 따라서 앞으로의 수질을 개선하기 위해서는 조류증식의 제한인자인 질소와 인의 규제가 필요할 뿐만아니라 하수처리장에 고차처리를 적용하거나, 해양의 회석자용을 이용한 Ocean을 적용하여 연안해역 수질을 관리해야 할 것이다. 따라서 본 연구는 수영만을 대상으로 Ocean Outfall과 폐수처리시절을 적절하게 조합하기 위해서 3차원 생태계모델을 적용하여 유기물질 뿐만 아니라 영양염류인 질소와 인의 농도를 예측하여 환경기준을 만족시키고 비용을 최소화 할 수 있는 폐수처리공법과 해중방류관의 위치를 선정하고자 하였다. 본 연구결과 수영만의 1994년 COD는 II등급, DIN과 DIP는 III등급이었다. 현재의 활성슬러지공법으로 질소와 인을 제거하지 않고 방류할 경우 2001년에 는 하수처리량의 증가로 인해 COD의 경우 1994년 보다 조금 감소하지만 DIN 과 DIP는 1994년과 같은 III등급을 유지하였다. 고도처리공법을 도입할 경우 COD의 농도는 광안리와 해운대해수욕장에서 I등급을 보이고, DIP의 농도도 수영만 전체에서 강등급을 보이지만, DM의 농도는 광안리해수욕장에서 II등급, 해운대해수욕장에서 IH등급을 보였다 하수처리장 유출수를 Ocean Outfall을 이용하여 하수처리장으로부터 4km에 서 방류할 경우의 COD농도는 I등급을 보이고, DE 농도도 광안리와 해운대해 수욕장에서는 I등급을 보이고, DU의 농도는 ll등급을 보여 수질이 개선된 것 을 볼 수 있다. 이상에서와 같이 광안리와 해운대해수욕장의 해역환경기준 ll등급을 만족 하는 하수처리방법은 Ocean Outfall이었다. 수영하수처리장에 인을 처리하기 위한 화학적 침전법의 경우 956억원이 소요되고, 질소를 제거하기 위한 질소제거공정을 추가 건설 할 경우는 2181억원이 전요된다. 그리고 두공정을 같이 건설할 경우에는 3137억원의 비용이 소요된다 수영하수처리장에서 4km 거리와 관경을 2m의 Ocean Outfall 건설비용은 325 억원 정도가 소요되는 것으로 산출되었다. 고차처리시 증가되는 비용으로 건설할 수 있는 Ocean Outfall의 길이는 인 제거공정을 첨가하는 경우에는 18km을 건설할 수 있고, 질소제거공정을 첨가 하는 경우에는 46km를 건설할 수 있는 것으로 산출되었다.

  • PDF

A Study on Characteristic of Underground Corrugated Steel Structure (파형강 지중구조물의 제특성 연구)

  • Park, Yeon Soo;Seo, Byoung Chal;Kim, Byong Ha;Park, Sun Joon
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.6
    • /
    • pp.693-702
    • /
    • 2001
  • Ductility pipes, like corrugated steel structures, are expected to reduce its deformation when they are arranged in a row. Verifying this assumption can help make economic designs possible. Though checking the deformation of ductility pipe structures, like corrugated steel structure, decreasing deformation was found when the pipes are arranged in a row. In this way, arranging a corrugated steel structures in a row shows decreased deformation compared to corrugated steel pipes arranged in a single structure because the bedding effect restrains deformation. The deformation rates of reduction are proportionate to the diameter of the corrugated steel structure.

  • PDF

Experimental Study for the Reinforcement of District Heating Pipe (지역난방 열배관 강화를 위한 실증시험 연구)

  • Kim, Jaemin;Kim, Jooyong;Cho, Chongdu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.40 no.3
    • /
    • pp.245-252
    • /
    • 2016
  • In this study, an alternative bend design is proposed to overcome the aging problem in piping bends. In this design, the foam pad is not included. Finite element analysis was performed based on the total pipe diameter. From this analysis, the shape of the Shear Control Ring (SCR) was determined. Temperature, stress, and other data of the proposed reinforced pipe were acquired and analyzed after the test was performed. The value of the thermal stress for the reinforced steel pipe satisfied the required standard without the foam pad based on the manufacturing of the reinforced fitting and construction site of the test. The reinforcement provided a shear strength level for the foam pad that resulted in maximum shear stress less than stress based on the original foam pad applied at the pipe bend. Additionally, an increasing factor of safety effect for the reinforced fitting application was discovered.

A Preliminary Study on the Construction or the AM/FM System for a Univesity (대학 시설물관리시스템 구축에 관한 기초적 연구)

  • 안기원;이효성;신석효
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.15 no.2
    • /
    • pp.277-286
    • /
    • 1997
  • The purpose of this study is to construct the AM/FM system for a university. The sample area used in this study is the Gyeongsang National University in Chinju City, Korea. The layout maps, which scale are 1/1200, 1/3000 and 1/5000, a map of planning of common duct, which scale is 1/1200, and the facility maps which scale is 1/200 were used for input of spatial data. The year of pipe buried, materials of pipe, pipe diameter, length of pipe, depth of pipe buried and slope of pipe buried were purpose of efficient data searching, analyzing, and processing. It was revealed that rapid providing of facility informations and efficient facility management are possible using the constructed the AM/FM system for a university.

  • PDF

Evaporation kent transfer characteristics of R-290 and R-600a in the horizontal tubes (수평관내 R-290과 R-600a의 증발 열전달 특성)

  • Son, Chang-Hyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.2
    • /
    • pp.264-269
    • /
    • 2008
  • This paper presents the experimental results of evaporation heat transfer coefficients of HC(e.g. R290 and R600a), R-22 as a HCFCs refrigerant in horizontal double pipe heat exchangers, having four different inner diameters of 10.07 mm and 6.54 mm respectively. The experiments of the evaporation process were conducted at mass flux of $35.5{\sim}210.4\;kg/m^2s$ and cooling capacity of $0.95{\sim}10.1\;kW$. The main results were summarized as follows : The average evaporation heat transfer coefficient of R-290 and R-600a was higher value than that of R-22. In comparison with R-22, the evaporation heat transfer coefficient of R-290 and 600a is approximately $56.7{\sim}70.1$ and $46.6{\sim}59.7%$ higher, respectively. In comparison with experimental data and some correlations, the evaporation heat transfer coefficients are well matched with the Kandlikar's correlation regardless of a type of refrigerants and tube diameters.

Validation Study on Processing Grip Part of Tensile Specimen Acquired from Corroded Pipeline (부식이 존재하는 기존 노후 관로에서 인장 시편 가공 시 그립 가공 타당성에 대한 연구)

  • Nam, Young Jun;Kim, Jeong Hyun;Bae, Cheol Ho;Lim, Yun Mook
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.40 no.2
    • /
    • pp.191-195
    • /
    • 2020
  • In this work, tensile tests, one of the most common test method to assess the condition of a corroded pipe, were conducted. According to ASTM E8 method, the use of flat or curved uni-axial tension test is allowed under the recommendation with the usage of grips corresponding to a curvature of the pipe. However, this method is not for corroded specimen. Furthermore, in the case of performing the multiple tensile tests with various curvatures, it is desirable not to produce zigs that fit each curvatures, if merely processing the specimen grip with curvature into the flat grip can show almost identical tensile behavior. Therefore, various tension simulations were conducted first to check if there exist any differences. Also, experiments on corroded tensile specimen were conducted and compared with the FEM simulation that reflects the actual geometry acquired from the 3D scanner.

A Study on Hydraulic Calculation Procedure of Fire Sprinkler System Design (스프링클러설비 설계의 수리계산 절차에 대한 연구)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.24-32
    • /
    • 2018
  • There are two kinds of method on hydraulic calculation of fire sprinkler system design. The one is using the computational program and the other is designer calculate system for oneself. In case of using the computational program, putting the input data in, the program calculate the friction loss, water flow, total height and so forth. If program user or designer doesn't know the basic idea and procedure of hydraulic calculation. Then, the outputs are different from each other. This paper suggests the hydraulic calculation procedure in design area as follow. Equivalent lengths of tees on the branch are selected base on the same pipe diameter which the tees are established, although the diameter of tee outlet is different. Even though there is a different friction loss of head from the other head, the pressure from the hydraulic end is bigger than a head loss, discharge flow is calculated by pressure from the hydraulic end.