• Title/Summary/Keyword: 과학성

Search Result 35,112, Processing Time 0.058 seconds

Analysis of the Seasonal Change of the Proximate Composition and Taste Components in the Conger Eels (Conger myriaster) (붕장어(Conger myriaster)의 일반성분 및 맛 성분의 계절별 변화 분석)

  • Ryu, Keun-Young;Shim, Sung-Lye;Kim, Won;Jung, Min-Seok;Hwang, In-Min;Kim, Jun-Hyeong;Hong, Cheul-Hee;Jung, Chan-Hee;Kim, Kyong-Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.8
    • /
    • pp.1069-1075
    • /
    • 2009
  • Conger eel (Conger myriaster) is used as a well-being food in the foodservice industry in Korea. We analyzed not only the proximate composition but also the taste components affecting conger eel, which are fatty acids, nucleotides, amino acids, etc. Concerning the composition, the crude lipid was the lowest in summer at 3.2%, which is considered due to spawning period. The major fatty acids were $C_{16:0},\;C_{16:1},\;C_{18:0},\;C_{18:1},\;C_{20:5},\;and\;C_{22:6}$. The $C_{18:1}$ content was the highest among the fatty acids and the content varied between 36.76 and 45.11% by season. Seasonal change in the content of poly-unsaturated fatty acids was increased from spring to winter in conger eel. Among the nucleotides, the contents of IMP (3.617$\sim$5.524 $\mu$mol/g) and Hx (0.913$\sim$2.238 $\mu$mol/g), which is closely related to taste, and the concentrations of IMP and Hx were the highest (7.219 $\mu$mol/g) in winter, and HxR (0.625$\sim$1.652 $\mu$mol/g) was higher than ATP (0.058$\sim$0.083 $\mu$mol/g), ADP (0.145$\sim$0.161 $\mu$mol/g), and AMP (0.166$\sim$0.179 $\mu$mol/g). In conger eels, the major total and free amino acids were glutamic acid (14,178.7$\sim$7,802.6 mg%), aspartic acid (4,669.2$\sim$8,259.0 mg%), lysine (4,198.3$\sim$7,540.8 mg%), leucine (3,843.6$\sim$6,782.1 mg%), and histidine (199.6$\sim$644.4 mg%), glycine (94.8$\sim$152.2 mg%), alanine (35.3$\sim$71.2 mg%), glutamic acid (44.1$\sim$70.6 mg%), respectively, but the concentration of amino acids was different by season. The content of free amino acids, which is related to the taste component, was detected as high in summer and winter at 1179.2 and 1,605.2 mg%, respectively.

Hybrid Scheme of Data Cache Design for Reducing Energy Consumption in High Performance Embedded Processor (고성능 내장형 프로세서의 에너지 소비 감소를 위한 데이타 캐쉬 통합 설계 방법)

  • Shim, Sung-Hoon;Kim, Cheol-Hong;Jhang, Seong-Tae;Jhon, Chu-Shik
    • Journal of KIISE:Computer Systems and Theory
    • /
    • v.33 no.3
    • /
    • pp.166-177
    • /
    • 2006
  • The cache size tends to grow in the embedded processor as technology scales to smaller transistors and lower supply voltages. However, larger cache size demands more energy. Accordingly, the ratio of the cache energy consumption to the total processor energy is growing. Many cache energy schemes have been proposed for reducing the cache energy consumption. However, these previous schemes are concerned with one side for reducing the cache energy consumption, dynamic cache energy only, or static cache energy only. In this paper, we propose a hybrid scheme for reducing dynamic and static cache energy, simultaneously. for this hybrid scheme, we adopt two existing techniques to reduce static cache energy consumption, drowsy cache technique, and to reduce dynamic cache energy consumption, way-prediction technique. Additionally, we propose a early wake-up technique based on program counter to reduce penalty caused by applying drowsy cache technique. We focus on level 1 data cache. The hybrid scheme can reduce static and dynamic cache energy consumption simultaneously, furthermore our early wake-up scheme can reduce extra program execution cycles caused by applying the hybrid scheme.

Development of a Remote Multi-Task Debugger for Qplus-T RTOS (Qplus-T RTOS를 위한 원격 멀티 태스크 디버거의 개발)

  • 이광용;김흥남
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.9 no.4
    • /
    • pp.393-409
    • /
    • 2003
  • In this paper, we present a multi-task debugging environment for Qplus-T embedded-system such as internet information appliances. We will propose the structure and functions of a remote multi-task debugging environment supporting environment effective ross-development. And, we are going enhance the communication architecture between the host and target system to provide more efficient cross-development environment. The remote development toolset called Q+Esto consists to several independent support tools: an interactive shell, a remote debugger, a resource monitor, a target manager and a debug agent. Excepting a debug agent, all these support tools reside on the host systems. Using the remote multi-task debugger on the host, the developer can spawn and debug tasks on the target run-time system. It can also be attached to already-running tasks spawned from the application or from interactive shell. Application code can be viewed as C/C++ source, or as assembly-level code. It incorporates a variety of display windows for source, registers, local/global variables, stack frame, memory, event traces and so on. The target manager implements common functions that are shared by Q+Esto tools, e.g., the host-target communication, object file loading, and management of target-resident host tool´s memory pool and target system´s symbol-table, and so on. These functions are called OPEn C APIs and they greatly improve the extensibility of the Q+Esto Toolset. The Q+Esto target manager is responsible for communicating between host and target system. Also, there exist a counterpart on the target system communicating with the host target manager, which is called debug agent. Debug agent is a daemon task on real-time operating systems in the target system. It gets debugging requests from the host tools including debugger via target manager, interprets the requests, executes them and sends the results to the host.

Luminescence and Photostimulated Luminescence of $Eu^{2+}$ in Alkaline Earth Chlorides (염화알칼리토금속 화합물에 도핑된 $Eu^{2+}$ 이온의 광발광 및 광자극발광특성)

  • Kim, Sung-Hwan;Kim, Sun-Chil
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.141-145
    • /
    • 2006
  • In this study, $Eu^{2+}$ ion was used as an activator in order to enhance the PL(photoluminescene) and PSL(photostimulated luminescence) intensity of $MCl_2:Eu^{2+}$(M = Ca, Sr, Ba)phosphors and the chracteristics of PL and PSL of the phosphors were investigated. The emission of $MCl_2:Eu^{2+}$(M = Ca, Sr, Ba) phosphors shows a shift wavelength when the host caution changes. The optimal preparing conditions of $CaCl_2:Eu^{2+}$ phosphor were 0.5 mol% of $EuCl_2$ and the sintering temperature were $745^{\circ}C$, 45 min. in $H_2$ atmosphere. The PL and PSL spectra of $CaCl_2:Eu^{2+}$ locate in the range of $365{\sim}388\;nm$, peaking at 370 and 380 nm. The optimal preparing conditions of $BaCl_2:Eu^{2+}$ phosphor were 0.5 mol% of $EuCl_2$ and the sintering temperature were $905^{\circ}C$, 45 min. in $H_2$ atmosphere. The PL and PSL spectra of $BaCl_2:Eu^{2+}$ locate in the range of $370{\sim}460\;nm$, peaking at 398 nm. The optimal preparing conditions of $SrCl_2:Eu^{2+}$ phosphor were 0.5mol% of $EuCl_2$ and the sintering temperature were $840^{\circ}C$, 45min. in $H_2$ atmosphere. The PL and PSL spectra of $SrCl_2:Eu^{2+}$ locate in the range of $380{\sim}440\;nm$, peaking at 407 nm. The dose response of the $MCl_2:Eu^{2+}$(0.5 mol%)(M = Ba, Sr) phosphors were linear within $0.25{\sim}200\;mGy$ of 100 kV X-ray and the PSL intensity of the $SrCl_2:Eu^{2+}$ and $BaCl_2:Eu^{2+}$ phosphors faded to approximately 60 and 40% respectively after 120 min at room temperature.

  • PDF

A Study on Reduction Effect of Processing Wastewater by Introduction of PACS (PACS 도입에 의한 현상시스템 폐수 감소효과에 관한 연구)

  • Ko, Shin-Kwan;Han, Dong-Kyoon;Kim, Wook-Dong;Kang, Bung-Sam;Yang, Han-Jun
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.167-175
    • /
    • 2007
  • There are some positive effects by the introduction of PACS(Picture Archiving Communication System). This study is to analyze the mutual relation between before and after of the introduction of PACS in terms of the environment effect. It is supposed to cause the reduction of developing and fixing wastewater according to the increase in the rate of a non-film. This study will also show the amount of wastewater. Target places were the department of image medicine(diagnostic radiation) of the general hospitals in Seoul and Gyeonggi-Do, which are equiped with full PACS. The authors examined questionnaires on the number of projection, the number of indirect projection, the amount of the film used, the number of radiation image CD loan, the amount of the developing and fixing solution used, the change of the amount of fixing wastewater. According to the analysis, we analyzed the change of the amount of developing and fixing solution per a film and the change of the amount of developing and fixing wastewater which is supposed to be reduced proportionally by the introduction of PACS. We got conclusion as below after analyzing 8 hospitals except the largest and the least amount of examination, film used, developing and fixing solution and the amount of developing and fixing wastewater in order to decrease the deviation from 10 general hospitals located in Seoul and Gyeonggi-Do. We compared data one year before adopting PACS Versus 3 years after adopting PACS. 1. The frequences of examination increased to 7,357.7 cases per month but the amount of film used decreased to 90%, from 42,774.4 to 4,181.88 after adopting the PACS. 2. 3 years after adopting PACS, monthly average amount of developing solution used decreased to 92% and the monthly average amount of fixing solution decreased to 86%. 3. Monthly average amount of developing solution used per film increased to 1.49 times and fixing solution increased as much as three times. 4. Monthly average wastewater for developing decreased to 88% and wastewater for fixing decreased up to 87%. 5. Monthly average wastewater for developing per film increased to 3.77 times and wastewater for fixing increased to 3.85 times. Although the amount of film used and the amount of developing and fixing wastewater affected by the reduction of the developing and fixing solution became less on the whole by introduction of PACS, they did not decrease proportionally. Moreover the amount of the developing and fixing solution used and the amount of developing and fixing wastewater per a film increased. That means the expectation for an environmental improvement differs from the actual condition.

  • PDF

The Evaluation of Image Quality and Radiation Dose in Multi-Detector CT (MDCT에서 화질과 방사선량에 관한 연구)

  • Han, Dong-Kyoon;Yang, Han-Joon;Kim, Moon-Chan;Ko, Shin-Gwan
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.129-138
    • /
    • 2007
  • The Purpose of this study is to suggest the basic data for making good quality image and maintaining equipment homeostasis by accepting image quality evaluation and radiation dose evaluation in Multi-detector CT. In this study we surveyed 14 CT equipments in Seoul. The results obtained were as follows ; CT number was $0.56{\pm}0.70\;HU$. Noise was $0.39{\pm}0.09\;HU$. Uniformity was $1.08{\pm}0.52\;HU$. High contrast resolution was $0.48{\pm}0.05\;mm$ and low contrast resolution was $3.65{\pm}1.16\;mm$. For CTDI, the central part and the peripheral part of head phantom were $43.2{\pm}15.4\;mGy$ and $45.6{\pm}17.5\;mGy$, respectively. For body phantom, the central part and the peripheral part of head phantom were $13.5{\pm}4.5$ and $29.2{\pm}10.2\;mGy$, respectively. CTDIw was $44.8{\pm}16.8\;mGy$ and CTDIw/100 mAs was $18.8{\pm}5.3\;mGy$ using head phantom. CTDIW was $24.0{\pm}8.3\;mGy$ and CTDIw/100 mAs was $10.1{\pm}2.5\;mGy$ using body phantom. Therefore, CT number, noise, high contrast resolution, low contrast resolution, CTDI, CTDIw and CTDIw/100 mAs of MDCT were showed excellently in all equipments.

  • PDF

Related Factors of Pneumothorax after Percutaneous Needle Aspiration Biopsy (폐 병소의 경피적 흡인 생검 시 기흉 발생 관련 요인)

  • Lee, Bo-Woo;Bae, Seok-Hwan;Lee, Moo-Sik;Lee, Jin-Yong;Kim, Chul-Woung;Cho, Bum-Sang;Yoo, Se-Jong;Hwang, Ji-Hea
    • Journal of radiological science and technology
    • /
    • v.34 no.3
    • /
    • pp.203-208
    • /
    • 2011
  • In this study, we investigated factors for affecting pneumothorax in percutaneous needle aspiration biopsy of lung lesions. This research were conducted at University Hospital in Daejeon from August 2007 to May 2008. Total 104 patients between the ages of 25~85 who had focal lung lesions were grouped in terms of the tumor location, tumor size, depth of lesion, gender, age, biopsy time, and the number of biopsies. Then, their correlations with pneumothorax were studied. The incidence of pneumothorax according to the positions showed 27.3% in the right lower lobe, 24.3% in the right upper lobe, 15% in the left lower lobe and 12% in the left upper, respectively. In addition, the incidence by lesion size showed 24.0% in 0~2.0 cm, 18.2% in 2.1~4.0 cm, above 20.0% in 4.1 cm respectively. The probabilities of pneumothorax was 6.7% at 0 cm depth of lesion, 24.2% at 0.1~2.0 cm and greater than 26.8% at 2.1 cm. By gender differences, we found that probability of incidence of pneumothrax is 21.7% for male and 17.1% for female. According to age, pneumothorax occurred in 25% in the group of less than 40-years-old, 11.7% in 41~50 years, 14.3% in 51~60 years, 24.1% in 61~70 years old and 24.1% in over 70 years. According to the time of biopsy, the incidence of pneumothorax was 3.8% from 0 to 10.0 minutes, 18.9% from 10.1 to 20.0 minutes and 40% more than 21 minutes.

The Study of Error for Analysis in Dynamic Image from the Error of Count Rates in NaI (Tl) Scintillation Camera (NaI (Tl) 신틸레이션 카메라에서 계수율 오차에 따른 동적 영상 분석치 산출 오류에 관한 연구)

  • Oh, Joo-Young;Kang, Chun-Goo;Kim, Jung-Yul;Park, Hoon-Hee;Oh, Ki-Baek;Kim, Jae-Sam
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.291-297
    • /
    • 2013
  • This study is aimed to evaluate the effect of $T_{1/2}$ upon count rates in the analysis of dynamic scan using NaI (Tl) scintillation camera, and suggest a new quality control method with this effects. We producted a point source with $^{99m}TcO_4^-$ of 18.5 to 185 MBq in the 2 mL syringes, and acquired 30 frames of dynamic images with 10 to 60 seconds each using Infinia gamma camera (GE, USA). In the second experiment, 90 frames of dynamic images were acquired from 74 MBq point source by 5 gamma cameras (Infinia 2, Forte 2, Argus 1). There were not significant differences in average count rates of the sources with 18.5 to 92.5 MBq in the analysis of 10 to 60 seconds/frame with 10 seconds interval in the first experiment (p>0.05). But there were significantly low average count rates with the sources over 111 MBq activity at 60 seconds/frame (p<0.01). According to the second analysis results of linear regression by count rates of 5 gamma cameras those were acquired during 90 minutes, counting efficiency of fourth gamma camera was most low as 0.0064%, and gradient and coefficient of variation was high as 0.0042 and 0.229 each. We could not find abnormal fluctuation in $x^2$ test with count rates (p>0.02), and we could find the homogeneity of variance in Levene's F-test among the gamma cameras (p>0.05). At the correlation analysis, there was only correlation between counting efficiency and gradient as significant negative correlation (r=-0.90, p<0.05). Lastly, according to the results of calculation of $T_{1/2}$ error from change of gradient with -0.25% to +0.25%, if $T_{1/2}$ is relatively long, or gradient is high, the error increase relationally. When estimate the value of 4th camera which has highest gradient from the above mentioned result, we could not see $T_{1/2}$ error within 60 minutes at that value. In conclusion, it is necessary for the scintillation gamma camera in medical field to manage hard for the quality of radiation measurement. Especially, we found a tendency that count rate changes over time at this study, and we proved that it can effect $T_{1/2}$. And also, there is need of appropriate phantoms and the method of quality management like this study, because there are not any advice or limitation degrees for domestic medical purpose scintillation camera.

Relationships of Changing Social Atmosphere, Lifestyle and Bone Mineral Density in College Students (대학생의 골밀도와 사회분위기 및 생활습관과의 관계)

  • Lee, In-Ja;Ko, Yo-Han;Kim, Chung-Kyung;Kim, Hee-Sol;Park, Da-Jeong;Yoon, Hyeo-Min;Jeong, Yu-Jin
    • Journal of radiological science and technology
    • /
    • v.36 no.4
    • /
    • pp.263-271
    • /
    • 2013
  • The decrease of bone mineral density gives rise to the outbreak of osteopenia and makes the possibility of a bone fracture. It makes health problems in society. It's very important to prevent osteopenia in advance. Also it's critical to prevent and take care of it in adolescent because it's the most developing period comparing to middle ages because that bone mineral density decreases. There are genetic, physical and enviromental factors that affect bone mineral density. Recently, a lifestyle and eating habits are also changing as the society atmosphere is gradually doing. This study have shown that 134 women and 75 men was chosen and responded to the survey of measuring bone mineral density and investigating a lifestyle. The measure of bone mineral density is to use Dual energy X-ray absorptiometry(DEXA) and check femoral neck and lumbar spine. Also questionaries was required to pre-made survey about their lifestyles. Analysis of data was done with SPSS program. Multiple regression analysis was used for the relation of bone mineral density, the heigths and BMI. The sample of Groups are checked for drinking, smoking or excercising about differences by t-test. The results of the experiments were; first, there is statistically significant differences in the comparisons between BMD and BMD. But there isn't any special correlation between drinking, smoking and BMD. Secondly, bone mineral density becomes low related to an intake of caffeine. Particularly, this is statically significant on women. Also there is statically significant correlation between femoral neck and quantity of motion for both men and women. Third, there is significant relation between eating habits and bone mineral density on women's lumbar spine. However, there is no significant relation between men's lumbar spine and women's one. Therefore, to prevent osteopenia, it's good to abstain from intaking caffeine within an hour after a meal. In addition, it's helpful to walk or run regularly and have a balanced meal.

Development of relative radiometric calibration system for in-situ measurement spectroradiometers (현장관측용 분광 광도계의 상대 검교정 시스템 개발)

  • Oh, Eunsong;Ahn, Ki-Beom;Kang, Hyukmo;Cho, Seong-Ick;Park, Young-Je
    • Korean Journal of Remote Sensing
    • /
    • v.30 no.4
    • /
    • pp.455-464
    • /
    • 2014
  • After launching the Geostationary Ocean Color Imager (GOCI) on June 2010, field campaigns were performed routinely around Korean peninsula to collect in-situ data for calibration and validation. Key measurements in the campaigns are radiometric ones with field radiometers such as Analytical Spectral Devices FieldSpec3 or TriOS RAMSES. The field radiometers must be regularly calibrated. We, in the paper, introduce the optical laboratory built in KOSC and the relative calibration method for in-situ measurement spectroradiometer. The laboratory is equipped with a 20-inch integrating sphere (USS-2000S, LabSphere) in 98% uniformity, a reference spectrometer (MCPD9800, Photal) covering wavelengths from 360 nm to 1100 nm with 1.6 nm spectral resolution, and an optical table ($3600{\times}1500{\times}800mm^3$) having a flatness of ${\pm}0.1mm$. Under constant temperature and humidity maintainance in the room, the reference spectrometer and the in-situ measurement instrument are checked with the same light source in the same distance. From the test of FieldSpec3, we figured out a slight difference among in-situ instruments in blue band range, and also confirmed the sensor spectral performance was changed about 4.41% during 1 year. These results show that the regular calibrations are needed to maintain the field measurement accuracy and thus GOCI data reliability.