• Title/Summary/Keyword: 과학기술 데이터

Search Result 2,575, Processing Time 0.038 seconds

A Study on the Collaboration Types of Knowledge Creation in Korean Government-supported Research Institutes of S&T: Focusing on Openness and Diversity (과학기술계 출연연구기관의 지식창출 협력유형 분석에 관한 연구: 개방성과 다양성 중심으로)

  • Park, Joohyoung;Lee, Heesang
    • Journal of Korea Technology Innovation Society
    • /
    • v.17 no.3
    • /
    • pp.563-583
    • /
    • 2014
  • We classified collaboration types of Government-supported Research Institutes (GRIs) in Korea to make a creation knowledge with the openness and the diversity. The openness is described to collaboration dependence and leading intensity, and the diversity is expressed to collaboration diversity and collaboration concentration. We suggest four taxonomy models explained in terms of the openness and the diversity with country level and institute level. This study uses 39,507 papers in SCOUPS DB that include author(s) affiliated to 26 GRIs. It concludes that many GRIs is classified to the type of multilateral collaboration follower in institute level and to the type of global network player in country level from the perspective of openness. In the aspect of diversity, many GRIs is concentrated to the collaboration type of picky eater or monophagous in institute level and to the multinatioal asymmetry type or non-multinational asymmetry type in country level. It is necessary for GRIs to lead collaboration and to transfer inhouse R&D institutes with high performance to be competitive institutes which make high quality knowledge.

1D, 2D interpretation of stream flooding by HEC-RAS and TELEAMC-2D (HEC-RAS, TELEMAC-2D 모형을 이용한 1, 2차원 하천 범람 해석)

  • Sim, Gyu Hyeon;Song, Si Hoon;Lee, Byung Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.394-394
    • /
    • 2015
  • 급격히 변화하고 있는 산업화와 도시화로 지구 온난화 현상으로 기상이변의 발생빈도가 높아졌고 기후가 불안정하여 예전보다 많은 집중호우가 발생하면서, 홍수로 인한 제내지 침수가 발생되기도 한다. 기후변화로 인한 수재해에 대응하기 위하여 하천 호소 수리 예측 모형의 개선이 필요한 실정이다. 하지만, 자연하천 유역의 강우-유출 상관관계와 지표면 유출현상 및 하도 수리 특성을 자연현상의 복잡성, 강우발생의 시간적 공간적인 발생과정의 임의성, 정확한 해석방법 및 확률 분석에 따르는 불확실성 들을 토대로 단순한 이론과 제한적인 경험공식 등에 의해서 해석, 재현 및 평가를 한다는 것은 매우 어려운 문제이다. 최근 IT 기술의 발전과 더불어, 많은 연구자, 엔지니어들이 기존 수리 수문학적 지식과 IT기술을 융합하여 복잡 다단한 수자원 환경 문제를 해결하고자 한다. 이와 같은 최근 연구 동향에 의거하여, 본 연구에서는 HEC-RAS, TELEMAC-2D 1, 2차원 수리 모형을 연계하여 하천 흐름 분석 및 홍수 범람 해석에 적용하였다. 본 연구에서는 HEC-RAS, TELEMAC 모형을 적용하여 2012년 태풍 '산바(SANBA)'로 인해 홍수 피해를 입은 고령군에 위치한 낙동강 본류 회천 유역(상류 회천교 ~ 하류 도진교)의 하도 내 흐름 분석과 하천 인근 제내지 홍수범람을 예측하였다. 범람해석에 필요한 지형자료를 기초로 하여 각 지형의 조건에 맞게 수치자료를 이용하여 작성하였고, 수자원 정보를 이용하여 유랑, 수위 등 시계열자료를 지류 및 상 하류의 경계조건으로 설정하고, 조도계수 등 하천 기본정보들을 입력하였다. HEC-RAS 모형은 회천교부터 도진교까지 전구간에 대한 종단면과 횡단면별 홍수침수범위 및 홍수위 크기 등 거시적인 1차원 수리해석에 적용하였고, TELEMAC 모형은 HEC-RAS 시뮬레이션 결과를 바탕으로 HEC-RAS에서 나타내기 힘든 2차원 흐름특성, 침수현상 등 일부 범람 구간에 대해 수리해석에 적용하였다. HEC-RAS 시스템은 수공구조물들의 영향과 하천의 영향을 종 횡단면으로 다양한 홍수침수 범위를 1차원으로 나타 낼 수 있으며, TELEMAC 시스템 수리 모의를 통해 얻어진 결과는 유속, 유량, 수심, 하상고 높이 등 2차원으로 나타낼 수 있다. TELEMAC 시스템을 활용한 2차원 분석은 실측자료와 비교적 유사하고 시각, 공간적으로 이해하기 쉽게 표현되므로, 모형 적용성이 우수한 것으로 판단된다. 향후 유역 해석을 위한 수치데이터, 수위, 유량자료를 확보하여 HEC-RAS, TELEMAC 1, 2차원 연계 모형을 적용 한다면, 하천 준설, 하천 구조물 설치, 홍수피해 등 전반적인 하천관리 계획에 활용할 수 있을 것이라 판단된다.

  • PDF

Design of EMI Reduction of SMPS Using MLCC Filters (MLCC를 이용한 SMPS의 EMI 저감 설계)

  • Choi, Byeong-In;Choa, Sung-Hoon
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.27 no.4
    • /
    • pp.97-105
    • /
    • 2020
  • Recently, as the data speed and operating frequencies of Ethernet keeps increasing, electro magnetic interference (EMI) also becomes increasing. The generation of such EMI will cause malfunction of near electronic devices. In this study, EMI filters were applied to reduce the EMI generated by DC-DC SMPS (switching mode power supply), which is the main cause of EMI generation of Ethernet switch. As the EMI filter, MLCCs with excellent withstanding voltage characteristics were used, which had advantages in miniaturization and mass production. Two types of EMI MLCC filters were used, which are X-capacitor and X, Y-capacitor. X-capacitor was composed of 2 MLCCs with 10 nF and 100 nF capacity and 1 Mylar capacitor. Y-capacitor was consisted of 6 MLCCs with a capacity of 27 nF. When only X-capacitor was applied as EMI filter, the conductive EMI field strength exceeded the allowable limit in frequency range of 150 kHz ~ 30 MHz. The radiative EMI also showed high EMI strength and very small allowable margin at the specific frequencies. When the X and Y-capacitors were applied, the conductive EMI was greatly reduced, and the radiation EMI was also found to have sufficient margin. In addition, X, Y-capacitors showed very high insulation resistance and withstanding resistance performances. In conclusion, EMI X, Y-capacitors using MLCCs reduced the EMI noise effectively and showed excellent electrical reliability.

Application and Analysis of Remote Sensing Data for Disaster Management in Korea - Focused on Managing Drought of Reservoir Based on Remote Sensing - (국가 재난 관리를 위한 원격탐사 자료 분석 및 활용 - 원격탐사기반 저수지 가뭄 관리를 중심으로 -)

  • Kim, Seongsam;Lee, Junwoo;Koo, Seul;Kim, Yongmin
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.6_3
    • /
    • pp.1749-1760
    • /
    • 2022
  • In modern society, human and social damages caused by natural disasters and frequent disaster accidents have been increased year by year. Prompt access to dangerous disaster sites that are inaccessible or inaccessible using state-of-the-art Earth observation equipment such as satellites, drones, and survey robots, and timely collection and analysis of meaningful disaster information. It can play an important role in protecting people's property and life throughout the entire disaster management cycle, such as responding to disaster sites and establishing mid-to long-term recovery plans. This special issue introduces the National Disaster Management Research Institute (NDMI)'s disaster management technology that utilizes various Earth observation platforms, such as mobile survey vehicles equipped with close-range disaster site survey sensors, drones, and survey robots, as well as satellite technology, which is a tool of remote earth observation. Major research achievements include detection of damage from water disasters using Google Earth Engine, mid- and long-term time series observation, detection of reservoir water bodies using Sentinel-1 Synthetic Aperture Radar (SAR) images and artificial intelligence, analysis of resident movement patterns in case of forest fire disasters, and data analysis of disaster safety research. Efficient integrated management and utilization plan research results are summarized. In addition, research results on scientific investigation activities on the causes of disasters using drones and survey robots during the investigation of inaccessible and dangerous disaster sites were described.

Mid to Long Term R&D Direction of UAV for Disaster & Public Safety (재난치안용 무인기 중장기 연구개발 방향)

  • Kim, Joune Ho
    • Journal of Aerospace System Engineering
    • /
    • v.14 no.5
    • /
    • pp.83-90
    • /
    • 2020
  • Disasters are causing significant damage to the lives and property of our society and are recognized as social problems that need to be solved nationally and globally. The 4th industrial revolution technologies affecting society as a whole such as the Internet of Things(IoT), Artificial Intelligence(AI), Drones(Unmanned Aerial Vehicles), and Big Data are continuously absorbed into the disaster and safety industries as scientific and technological tools for solving social problems. Very soon, twenty-nine domestic UAV-related organizations/companies will complete the construction of a multicopter type small UAV integrated system ('17~'20) that can be operated at disaster and security sites. The current work considers and proposes the mid-to-long term R&D direction of disaster UAV as a strategic asset of the national disaster response system. First, the trends of disaster and safety industry and policy are analyzed. Subsequently, the development status and future plans of small UAV, securing shortage technology, and strengthening competitiveness are analyzed. Finally, step-by-step R&D direction of disaster UAV in terms of development strategy, specialized mission, platform, communication, and control and operation is proposed.

A Study on the Structure of Research Domain for Internet of Things Based on Keyword Analysis (키워드 분석 기반 사물인터넷 연구 도메인 구조 분석)

  • Namn, Su-Hyeon
    • Management & Information Systems Review
    • /
    • v.36 no.1
    • /
    • pp.273-290
    • /
    • 2017
  • Internet of Things (IoT) is considered to be the next wave of Information Technology transformation after the Internet has changed the process of doing business. Since the domain of IoT ranging from the sensor technology to service to the users is wide, the structure of the research domain is not delineated clearly. To do that we suggest to use the Technology Stack Model proposed by Porter et al.(2014) to measure the maturity level of IoT in organizations. Based on the Stack Model, for the general understandings of IoT, we do keyword analyses on the academic papers whose major research issue is IoT. It is found that the current status of IoT application from the perspectives of cloud and big data analytics is not active, meaning that the real value of IoT has not been realized. We also examine the cases which deal with the part of cloud process which is crucial for value accrual. Based on these findings, we suggest the future direction of IoT research. We also propose that IT is to value chain what IoT is to the Stack Model to derive value in organizations.

  • PDF

Development of continuous blood pressure measurement system using ECG and PPG (ECG와 PPG를 이용한 실시간 연속 혈압 측정 시스템)

  • Kim, Jong-Hwa;Whang, Min-Cheol;Nam, Ki-Chang
    • Science of Emotion and Sensibility
    • /
    • v.11 no.2
    • /
    • pp.235-244
    • /
    • 2008
  • This study is to develop automatic extraction system of continuous blood pressure using ECG (Electrocardiogram) and PPG(Photoplethysmography) for u-health care technology. PTT (Pulse Transit Time) was determined from peak difference between ECG and PPG and its inverse made to get blood pressure. Since the peaks were vulnerable to be contaminated from noise and variation of amplitude, this study developed the adaptive algorithm for peak calculation in any noise condition. The developed method of the adaptive peak calculation was proven to make the standard deviations of PPT decrease to 28% and the detection of noise increase to 18%. Also, the correlation model such as blood pressure = -0.044 $\cdot$ PTT + 133.592 has successfully been determined for predicting the continuous pressure measured without using cuff but with using PPG and ECG, only.

  • PDF

Analysis on Time Lag Effect of Firm's R&D Investment (기업 R&D 투자의 시차효과 분석)

  • Lee, Hun-jun;Baek, Chulwoo;Lee, Jeong-dong
    • Journal of Technology Innovation
    • /
    • v.22 no.1
    • /
    • pp.1-22
    • /
    • 2014
  • R&D investment also has a gestation period similar to other investments in economics. The gestation period originates from time lag effect of input and output. Thus it is necessary to consider time lag effects when analyzing the relationship between firms' R&D investment and R&D performance. The main objective of this research is to estimate the length of time lag effect of R&D investment. The Almon distribution lag model was applied to estimate the time lag effect. The firm level panel dataset was established from 2002 to 2009. The net value of R&D investment and the number of patent applications were used to measure R&D input and output, respectively. This method found the estimated time lag to be 1~2 years across all datasets. The same analyses were applied to chemical, metal, electronic, exact science, and machinery industries' data. And we found there were differences among sectors in regard to the time lag effect.

Correction Method of Slit Modulation Transfer function on Digital Medical Imaging System (디지털 의료영상에서 슬릿법에 의한 Modulation Transfer Function의 보정방법)

  • Kim, Jung-Min;Jung, Hoi-Woun;Min, Jung-Whan;Im, Eon-Kyung
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.133-139
    • /
    • 2006
  • By using CR image pixel data, We examined the way how to calculate the MTF and digital characteristic curve. It can be changed to the text-file(Excel) from a pixel data which was printed with a digital x-ray equipment. In this place, We described the way how to figure out and correct the sharpness of a digital images of the MTF from FUJITA. Excel program was utilized to calculate from radiography of slit. Digital characteristic curve, Line Spread Function, Discrete Fourier Transform, Fast Fourier Transform digital specification curve, were indicated in regular sequence. A big advantage of this method, It can be understood easily and you can get results without costly program and without full knowledge of computer language. It shows many different values by using different correction methods. Therefore we need to be handy with appropriate correction method and we should try many experiments to get a precise MTF figures.

  • PDF

Correction Method of Wiener Spectrum (WS) on Digital Medical Imaging Systems (디지털 의료영상에서 위너스펙트럼(Wiener spectrum)의 보정방법)

  • Kim, Jung-Min;Lee, Ki-Sung;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.32 no.1
    • /
    • pp.17-24
    • /
    • 2009
  • Noise evaluation for an image has been performed by root mean square (RMS) granularity, autocorrelation function (ACF), and Wiener spectrum. RMS granularity stands for standard deviation of photon data and ACF is acquired by integration of 1 D function of distance variation. Fourier transform of ACF results in noise power spectrum which is called Wiener spectrum in image quality evaluation. Wiener spectrum represents noise itself. In addition, along with MTF, it is an important factor to produce detective quantum efficiency (DQE). The proposed evaluation method using Wiener spectrum is expected to contribute to educate the concept of Wiener spectrum in educational organizations, choose the appropriate imaging detectors for clinical applications, and maintain image quality in digital imaging systems.

  • PDF