• Title/Summary/Keyword: 과도상태해석

Search Result 226, Processing Time 0.03 seconds

Comparative Study on Classical Control and Modern Control via Analysis of Circuit-based Time Response (회로망 기반의 시간응답 해석에 따른 고전제어와 현대제어의 비교 연구)

  • Min, Yong-Ki
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.12 no.4
    • /
    • pp.575-584
    • /
    • 2017
  • It is suggested the circuit network to analyze the time response of control system. And it is analyzed the interrelation for classical control and modern control by the transfer function and the state equation. Without complicated integration of state transition equation, it is suggested to possible time response by combining the state transition matrix and the transfer function. A source program is coded to display the time response according to the unit-step and the sinusoidal input. Transient response is analyzed in the unit-step input and phase difference between current and voltage is analyzed in sinusoidal input. As writing the suggested contents in transient response or state-space analysis, it is improved the understanding for control engineering and ability for system design.

Transient Analysis of Liquid Rocket Engine around the Nominal Thrust Level (정상상태 부근에서의 액체로켓 엔진의 과도해석)

  • Choi Hwan-Seok;Seol Woo-Seok;Park Soon-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.68-76
    • /
    • 2004
  • It is essential to develop a transient engine system analysis model for turbopump fed type liquid rocket engine development, especially for deriving engine system test number and conditions. In this study, we proposed a mathematical model of turbopump fed type liquid rocket engine, and inspected transient mode changes around the nominal thrust level of a rocket engine according to variations of trust control valve's opening ratio. To verify the results, we solved the same problem with AnaSyn software from Russia, and concluded that the transient code showed the similar results within $2\%$ with AnaSyn.

  • PDF

The Evaluation of Damping by STATCOM in Power System Transient State (전력계통 과도상태에서의 STATCOM에 의한 제동력 평가)

  • Park, Ji-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.99-100
    • /
    • 2008
  • 본 논문은 전력계통의 과도상태에서의 STATCOM에 의해 제공되는 제동력을 평가한다. 기존의 논문들은 FACTS장비가 시스템의 안정도에 영향을 주는 제동력을 주로 고유치해석을 통하여 평가하였지만 본 논문은 에너지함수를 이용하여 FACTS장비에 의한 추가적인 제동력을 평가한다. 동기발전기의 상세모델링을 사용한 에너지함수를 통하여 STATCOM의 제동력이 전력계통의 과도 안정도에 미치는 영향을 시뮬레이션한다. 1기무한대모선 시스템에 적용한 결과를 보인다.

  • PDF

Power System Stability Analysis Using a Hybrid Approach (하이브리드 방법을 이용한 전력계통의 안정도 해석)

  • Park, Ji-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.11b
    • /
    • pp.218-220
    • /
    • 2002
  • 본 논문은 시간영역 모의 테크닉과 과도안정도 해석 직접법을 결합한 하이브리드형 방법을 설명한다. 먼저 객체지향기법을 이용한 시간영역 모의를 통해 실제 시스템의 궤도를 계산하고, 과도안정도 여유도를 계산하기 위한 안정도 지수를 유도하기 위해 과도 에너지함수를 평가한다. 일단 시스템의 어떤 상태(안정 또는 불안정)가 확인되면 CPU 시간을 줄이기 위해 시간영역 모의를 중단하기 위한 적절한 기준이 제시되었다.

  • PDF

Transient Analysis of the CANDU-9 480/SEU Reactor (CANDU-9 480/ SEU 원자로의 과도변화해석)

  • J. C. Shin;Park, J. H.;K. N. Han;H. C. Suk
    • Nuclear Engineering and Technology
    • /
    • v.27 no.5
    • /
    • pp.687-700
    • /
    • 1995
  • The thermal-hydraulic transient analysis of the proposed CANDU-9 plant was peformed. Several major transients ore analyzed if they meet the heat transport system design requirements. The proposed heat transport system configuration and the preliminary sizes of system equipment are justified by analysis in terms of the fuel integrity and the high system pressure limit during transients. The compliance with AECB R-77 requirements for CANDU-9 reactor was estimated. The analysis results showed that for each postulated accident the peak pressure values in the reactor headers are within the acceptance criteria given in ASME code requirements and the fuel overheating is prevented. One pump start-up during the reactor start-up operation was analyzed to investigate the How reversal through the fuel channel, which is specific in the proposed CANDU-9 plant.

  • PDF

Analysis of the Transient Dynamic Response of Ocean Mining Pipe System Due to Impulse (임펄스 가진에 의한 근해역 통합채광시험 양광시스템의 파이프 동적 과도응답 해석)

  • Cho, Kyu-Nam;Kim, Min;Park, Yong-Chan;Yoon, Chi-Ho
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.20 no.2
    • /
    • pp.105-111
    • /
    • 2007
  • A finite element analysis scheme is proposed to assess the dynamic response due to impulse excitation of ocean mining pipe system. Transient dynamic response analysis based on the proposed scheme was carried out for various types of impulses, and the magnitude of cable tension induced by impulse was discussed by using a model of 'Segero', a special purpose ship of KT-Submarine as well as ROV carrier 'Onnuri' A qualitative, prospective guideline for the relevant marine operation is obtained.

Thermal Isolation Technology for Cryogenic Cooling Devices (극저온 냉각 장치를 위한 단열 기술)

  • 김호영;강병하
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.11
    • /
    • pp.24-30
    • /
    • 2002
  • 본 글에서는 정밀 전자 소자등을 극저온으로 냉동시키는 데 필요불가결한 극저온 단열 기술에 대하여 간단히 알아보았다. 역사가 가장 오래되고 기본적인 진공 단열 기술로 시작하여, 공간에 고형의 물질을 삽입하는 다층 단열 기술과 분말 단열 기술에 대하여 토의하였다. 실제 응용시에는 요구되는 열적 성능과 경제적 제한 조건을 고려하여 가장 적합한 단열 방법을 선정하도록 하여야한다 또한 극저온 단열 용기의 실제 열해석 예로서 적외선 센서의 극저온 용기에 대한 정상 및 과도 열전달 해석에 대하여 간단히 기술하였다. 정상상태의 경우는 많은 경우 해석적인 해를 구할 수 있지만, 시간에 따라 온도가 변하는 과도 상태의 경우는 수치해석적인 방법이 요구된다. 열해석에서 일반적으로 쓰이는 유한차분법이 극저온 단열 용기의 열해석에도 유용하게 쓰일 수 있음을 보였다.

The Analysis and Test of Dynamic Characteristics for Line Starting Permanent Magnet Motor (유도성 기동 영구자석 전동기의 기동특성 해석 및 시험)

  • Hwang, Sang-Yeon;Cha, Jong-Hwan;Han, Sang-Yul;Cho, Dong-Hyeok
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.22-24
    • /
    • 2003
  • 유도성 기동 영구자석 전동기의 경우 고효율성 및 자기동성으로 인해 현재 산업계에서 많이 사용되고 있는 유도기를 대체할 가능성이 크다. 정상 상태에서는 영구자석 동기 전동기로 작동하며 기동시에는 유도바의 역할로 유도기로서 동기화에 이르게 된다. 이때, 적절한 설계가 이루어지지 않으면 기동 또는 동기화에 실패할 수 있으므로 기동시의 과도특성 해석은 매우 중요하다. 본 논문에서는 기계 방정식과 결합된 유한요소해석 프로그램을 이용하여 전동기의 기동 및 동기화 특성을 해석하고자 한다. 해석의 타당성을 검증하기 위하여 시험용 전동기를 제작하고 과도 상태 시험을 수행하여 해석결과와 비교한다.

  • PDF

DQ Synchronous Reference Frame Model of A Series-Parallel Tuned Inductive Power Transfer System and Current Controller (직렬-병렬 무선 전력 전송 시스템의 DQ 동기 좌표계 모델 및 전류제어기)

  • Noh, Eunchong;Lee, Sangmin;Lee, Seung-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2020.08a
    • /
    • pp.181-183
    • /
    • 2020
  • 본 논문에서는 DQ 변환을 적용한 직렬-병렬 공진형 무선전력 전송 시스템의 동기 좌표계 모델과 이를 이용한 전류제어기 시스템을 제안한다. 무선 전력 전송 시스템은 일반적으로 급전 측과 집전 측에 단상 전류가 흐르기 때문에 제어에 어려움이 있다. 따라서 정상 상태의 전압 및 전류의 수식을 이용하여 부하에 전달되는 전압 및 전류의 크기를 제어하는 경우가 많다. 따라서 과도 상태의 전압 및 전류의 동특성이 원하는 특성과 다르게 나타날 수 있다. 본 논문에서는 직렬-병렬 공진형 무선전력 전송 시스템의 단상 전압 및 전류를 DQ 변환하여 과도 상태 및 정상 상태의 전압 및 전류의 동특성을 해석할 수 있는 등가 회로 모델을 제시하고 이를 이용하여 과도 상태 제어를 위한 고성능 전류 제어기를 제안한다.

  • PDF

A Comparative Study of Gas Turbine Models for the Enhancement of Power System Stability (전력계통 과도안정도 향상을 위한 가스터빈 모델링 비교 연구)

  • Kim, Dong-Joon;Lee, Joon-Joo;Moon, Young-Hwan
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.229-230
    • /
    • 2015
  • 본 논문은 전력계통 과도안정도 해석에서 많이 쓰이고 있는 가스터빈 모델인 GAST 모델과 GAST2A 모델에 대해서 과도안정도 관점에서 모의 비교한다. 두 가스터빈 모델은 1기 무한모선으로 계통을 구성하여 정상상태에서 조속기 10% 스텝응동 특성을 모의하여 서로 응동특성이 같도록 모델정수를 튜닝하였다. 그리고 발전단에 150 ms 3상 단락사고를 발생시켜 과도상태 특성을 비교하였다. 3상 단락사고인 경우 배기가스 온도제한이 없는 정상 출력상태인 경우와 온도제한 제어특성이 활성화 되는 출력인 경우를 상정하여 비교 분석하였다.

  • PDF