• Title/Summary/Keyword: 공중선

Search Result 154, Processing Time 0.019 seconds

Dental Service System and Oral Health Providers in Correctional Institutions (구금시설의 치과진료체계 및 구강보건의료인력 현황 조사)

  • Kang, Jung-Yun;Kim, Young-Hyun;Oh, Kyung-Sun;Jo, Yeon-Suk;Lee, Min-Sun;Kim, Nam-Hee
    • Journal of dental hygiene science
    • /
    • v.9 no.5
    • /
    • pp.507-511
    • /
    • 2009
  • The purpose of this study is to analyze the dental service system in correctional institutions and 10 find the factors for improving inmates' oral health. This study is comprised of document review, telephone and questionnaire survey. The subjects of questionnaire survey are public health dentists and doctors in correctional institutions. They responded to questionnaire and the survey was collected from previous research and selected information about the dental service system. The findings of the study were as follow : Documentary survey 1. According to 2004's study, there are 42 dental offices in 46 all correctional institutions. 2. Criminals who took an health examination occupied 69.0% when committed to a jail in 2002's study. Majorities of them(81.5%) responded that they didn't take any oral examination. Telephone & Questionnaire survey 1. Full-time public health dentists are 26 in 2009. There is no correctional institution having oral health providers in 26 correctional institutions surveyed. 2 About 10 patients use the dental services in a day. Part-time dentists visit 4 times a month as average in 80% of institutions. 40% of institutions responded dental treatments can't be progressed conveniently because of the lack of oral health providers. 3. 80% of respondents answered that it is hard to cure prisoners, and that's because they are forbidden to get out of the institutions. 4. Only 20% of correctional institutions offered the oral hygiene instructions. There is no regular oral hygiene education for all inmates. 5. They need to increase the number of oral health providers.

  • PDF

Some effects of rice weevil (Sitophilus oryzae L.) on the moisture contents of polished rice (쌀바구미(Sitophilus oryzae Linne)의 현미함수량에 미치는 영향)

  • HYUN Jai Sun
    • Korean journal of applied entomology
    • /
    • v.1
    • /
    • pp.20-25
    • /
    • 1962
  • A. The increases moisture contents of grain at R.H $75\%,\; and\; 28^{\circ}C$ 1) The moisture contents of polished rice were $0.4\%,\; 1 \%,\; 3.3\%$ higher than control after 4weeks in which had been infested with 100, 200, 500 individuals of weevil at the beginning. respectively. 2) The greatest moisture contents of polished rice was $16.26\%$ for 500 individual infested grain and the lowest one was $14.86\%$ for the 100 individual weevil infested grain after 4 weeks. 3) The increases in moisture contents of grain were proportionally greater with the size of the weevil population. B. Changes in moisture contents of polished rice at the three levels of cylinder which contain 3kgs of grain and 1000 weevils were infested at the beginning of the experiment. 1) The moisture contents of the grain at all the levels of the cylinder which was not infested with weevil, were consistantly decreased in 12 weeks. 2) The moisture contents of the grain at all the levels of the cylenders which had been infested with 1000 weevils at the beginning of the experiment, were increased except top lovel, that were $15.6\%$ for middle, $41.55\%$ for the bottom levels after 12 weeks. 3) The moisture contents of the grain were greater toward bottom in both weevil infested grain and in control. 4) The moisture content increase might be caused by the respiration of the weevils and deterioration of the grain by microorganisms. 5) There were no tendency to confine the weevils at any definite levels, but as the deterioration of the grain goes on, the weevil moved to top levels of cylinders. 5) The decreases in moisture contents of the grain at the top levels of the cylinders might be caused by diffusion of water to the environment. 7) The differences in temperature at three levels of the cylinder from enviroment were little or negative in control but were greater and positive. and the bottom were higher than top in experimental cylinders. 8) The increases of temperature might be caused by the respiration of the weevil and microorganisms.

  • PDF

Microbiological Hazard Analysis and Verification of Critical Control Point (CCP) in a Fresh-Cut Produce Processing Plant -Case Study of a Fresh-Cut Leaf Processing Plant- (신선편이 농산물 가공업체의 미생물학적 위해 요소 분석 및 중점 관리 지점(CCP)의 검증 -신선편이 엽채류 가공업체를 대상으로-)

  • Kim, Su-Jin;Sun, Shih-Hui;Min, Kyung-Jin;Yoon, Ki-Sun
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.21 no.3
    • /
    • pp.392-400
    • /
    • 2011
  • The objectives of this study were to analyze environmental microbial contamination levels by sampling the surfaces of processing lines and equipment and to verify CCPs of the HACCP plan in a fresh-cut produce processing plant The level of airborne microorganisms in the processing plant was $10^1$ log CFU/plate/15min. Total plate counts and coliform groups of the processing facilities were 1~2 log CFU/100 $cm^2$. No E. coli or S. aureus were detected in the processing plant. However, total plate counts on the cutting board for raw materials and on the spin-dryer were $4.20{\pm}2.12$ log CFU/$cm^2$ and $4.57{\pm}0.92$ log CFU/$cm^2$, respectively. These levels were higher than the safe microbial level, and therefore, the chance of cross-contamination during processing was increased. According to the results of microbiological analyses, total aerobic bacteria and coliform groups of the samples were increased after the second washing and spin-drying steps, due to cross-contamination from the spin-dryer. Thus, an effective method that can be used for microbial control during the washing and drying steps is needed for microbial control in fresh-cut produce processing plants. The results of a verification study also suggest that modification of the HACCP plan is needed along with additional CPs, which were identified as a second washing, spin drying, and the cold storage of final products.

Comparative Evaluation of the VITEK 2 System and Species-specific PCR Methods for the Detection of Vibrio Species Isolated from Shrimp (새우에서 분리된 Vibrio species 동정을 위한 VITEK 2 system방법과 species-specific PCR방법 비교 평가)

  • Lee, Jeong-Min;Lee, Won-Jun;Kim, Min-Ju;Cho, Yong-Sun;Lee, Jin-Sung;Lee, Hyun-Jin;Yoon, Sang-Woo;Kim, Keun-Sung
    • Journal of Food Hygiene and Safety
    • /
    • v.30 no.3
    • /
    • pp.281-288
    • /
    • 2015
  • Vibrio is a genus of Gram-negative, curved, halophilic, and non-spore-forming bacteria. Some of the Vibrio species, such as V. cholerae and V. parahaemolyticus, often contaminate seafood products and occasionally cause human diseases when the seafood products are ingested. A total of 24 Vibrio strains were isolated from shrimp samples on Thiosulphate citrate bile salt sucrose (TCBS) media in this study. All of the 24 isolates were confirmed to belong to the genus Vibrio by using 16S rRNA gene sequence analyses. Vitek 2 system and species-specific polymerase chain reaction (PCR) methods were used to further identify a total of 29 Vibrio strains at the species level, including the 24 shrimp Vibrio isolates and five Vibrio reference strains. The specificities of the two methods to identify Vibrio strains at the species level were compared in this study. The species-specific PCR method was designed to detect five different Vibrio species, such as Vibrio cholerae, Vibrio parahaemolyticus, Vibrio vulnificus, Vibrio alginolyticus, and Vibrio mimicus. From the 24 Vibrio shrimp isolates, the Vitek 2 system method could identify 15 (62.5%) strains as Vibrio species and 7 (29.2%) strains as non-Vibrio species, but could not identify the rest 2 (8.3%) strains. But species-specific PCR method could identify 16 (66.7%) strains as Vibrio species and could not identify the rest 8 (33.3%) strains. Among the 24 Vibrio shrimp strains, these two methods could unanimously identify 7 (7/24, 29.2%) strains (2 V. parahaemolyticus, 4 V. alginolyticus, and 1 V. mimicus). Considering that such different identification results were obtained using the two different methods in this study, identification method for Vibrio species must be carefully chosen.