• Title/Summary/Keyword: 공조시스템(air conditioning system)

Search Result 262, Processing Time 0.021 seconds

The Performance Analysis of a Return Air Bypass Air Conditioning System by a Simulator Experiment (실물실험에 의한 순환공기 바이패스 공조시스템의 성능분석)

  • 신현준;김보철;김정엽
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.130-135
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; outdoor air bypass, mixed air bypass and return air bypass system. Among bypass air conditioning systems, a return air bypass system is more effective than other two systems because it doesn't induce unconditioned outdoor air into conditioned room. The numerical study on the bypass air conditioning system shows this system can maintain indoor RH(Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. A simulator was built to compare results of a numerical experiment and those of a simulator experiment. The results of the simulator experiment was nearly same as those of the numerical experiment; when a design sensible load (the ratio of sensible load to total sensible load) was 70 percent (at this time, RSHF=0.7), indoor relative humidity (in case of both numerical experiments and simulator experiments) was maintained below 60% specified by ASHRAE STANDARD 62-1999. The bypass air conditioning system is expected to be applied to many buildings where the Percentage of latent loads or air change tate is high.

A Study on the Improvement of Performance for Centralized Air Conditioning System by Using Air-Cooled Air Conditioner - The Case of Mokpo National Maritime University - (공랭식 에어컨을 이용한 중앙 집중 공조시스템의 성능 개선에 관한 연구 - 실습선 새누리호를 중심으로 -)

  • Kim, Hong-Ryel;Han, Seung-Hun
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.19 no.2
    • /
    • pp.207-212
    • /
    • 2013
  • In this study, distributed the ship's Centralized Air Conditioning System the way an individual to replace the air conditioning system by using Air-cooled air conditioner. Research results, Individually separated air conditioning system complement the heat source control and thermal efficiency problems and improves the efficiency of the device was confirmed. In addition, under the same conditions refrigeration capacity and coefficient of performance of the device, an average of about 3 %, 23 ~ 26 %, higher, Chilled Water Plants Compressor power consumption is about 12 % lower. Also while heating under the same conditions, power consumption is about 33.5 % lower. Therefore Individually Separated Air Conditioning System greatly contributed to the improved performance of the device and living spaces for comfortable temperature and humidity control as well as heating source could be obtained.

A Study on the Simulator and Trouble Prediction Monitoring Methodology of the Automotive Air Conditioner (자동차 공조기의 시뮬레이터 및 고장예측 모니터링 기술에 관한 연구)

  • Son, Il-Moon;Kwak, Hyo-Yean
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.4
    • /
    • pp.1568-1575
    • /
    • 2013
  • There has been an increasing interest in the market of vehicle maintenance and repair equipments to decrease air pollution. However, most of the existing air conditioning system equipment in Korea have poor performance as well as non-protection against air pollution. The purpose of this paper is to develop the monitoring technology of recovering and recharging refrigerant for air conditioning system, and also to develop its related diagnostic system. This technology and system can supply the exact amount of refrigerant from the charger to the air conditioning system by precisely diagnosing and monitoring their statuses. This technology can also control recovering and recharging of refrigerant exactly by altering the recovering pressures of refrigerant according to circumstance temperatures.

Task/Ambient Air-Conditioning System의 연구 개발사례 및 향후 과제

  • 타나베신이치
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.8
    • /
    • pp.9-17
    • /
    • 2004
  • 차세대의 공조시스템을 논의하는 데 있어서 잊어서는 안 되는 키워드 중의 하나가 “Task/Ambient Air-Conditioning System”이 있다. 이것은 기존의 실내온열환경을 균일하게 조절한다는 개념에서, 거주역(Task-zone)에 대해서는 고품질의 환경을, Ambient-zone에 대해서는 다소 완화된 환경을 제고하고자 하는 생각으로, 퍼스널 공조와 같은 고도화된 공조시스템에서 자연환기의 이용에 이르기까지 폭넓은 범위에 미치고 있다. (중략)

  • PDF

Fuzzy Control Algorithms for the Compressor and the Electronic Expansion Valve of a Multi-type Air-conditioning System using Multiple Input Variables (다입력변수를 사용한 멀티형 공조시스템 압축기와 전자팽창밸브의 퍼지 제어 알고리즘)

  • Han, Do-Young;Park, Kwan-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.163-171
    • /
    • 2006
  • In order to control multi-zone temperatures, a multi-type air-conditioning system may be used. In this study, control algorithms for the compressor and the electronic expansion valve of a multi-type air-conditioning system were developed by using fuzzy logics. The compressor control algorithm was composed of a compressor pressure setpoint algorithm, a compressor pressure setpoint reset algorithm, and a compressor frequency setpoint algorithm. The electronic expansion valve control algorithm was composed of an indoor temperature control algorithm, and a superheat control algorithm. These algorithms were applied to a multi-type air-conditioning system. Test showed good results for the control of a multi-type air-conditioning system.

기존의 퍼스널 공조시스템의 문제점 및 그 개선방안

  • 송두삼
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.8
    • /
    • pp.41-47
    • /
    • 2004
  • 최근 국내에서도 개별제어를 지향하는 공조시스템의 오피스건물에의 적용이 적극적으로 검토되고 있으며 또 몇몇 실제 적용된 사례가 보고되고 있다. 그 내용을 보면, 바닥취출공조시스템이나 시스템 에어컨이 대부분으로 어떤 의미에서 본격적인 개별공조 (personal air-conditioning system)라고 할 수 없으며, 오히려 실의 공조죠닝을 세분화해 국부적인 재어성을 향상시킨 쾌적성 향상 또는 에너지절약 시스템이라고 할 수 있다. (중략)

  • PDF

Study on Non-uniform Thermal Comfort in Hybrid Air-Conditioning System with CFD Analysis (CFD 해석을 통한 하이브리드 공조시스템의 인체 온열감의 불균일성에 관한 연구)

  • Nam, Yu-Jin;Sung, Min-Ki;Song, Doo-Sam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.216-222
    • /
    • 2011
  • Recently, hybrid air-conditioning system has been proposed and applied to achieve building energy saving. One example is a system combining radiation panel with natural wind-induced cross-ventilation. However, few research works have been conducted on the non-uniformity of thermal comfort in such hybrid air-conditioning system. In this paper, both thermal environment and non-uniform thermal comfort of human thermal model under various air-conditioning system, including hybrid system, were evaluated in a typical office room using coupled simulation of computation fluid dynamics, radiation model and a human thermal model. The non-uniformity of thermal comfort was evaluated from the deviation of surface temperature of human thermal model. Flow fields and temperature distribution in each case were represented.

Optimal Control Algorithm for the Dual Source Chiller Air Conditioning System (복합 열원 공조시스템의 최적 제어 알고리즘)

  • Han, Do-Young;Kim, Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.9
    • /
    • pp.881-888
    • /
    • 2004
  • Control algorithms for a dual source chiller air conditioning system were developed. These are control algorithms for the supply air temperature control, the supply header chilled water temperature control, the chiller chilled water temperature control, and the cooling tower water temperature control. These algorithms were analyzed by using a dynamic simulation program. Simulation results showed the energy savings and the satisfactory controls of an absorption and centrifugal chiller air conditioning system. Therefore, control algorithms developed for this study may effectively be used for the improved controls of the dual source chiller air conditioning system.

Development of HVAC System to Lower the Conveyance Energy and Building Height (반송동력과 건물층고 저감형 공조시스템 개발)

  • 김정엽;신현준
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.15 no.2
    • /
    • pp.116-125
    • /
    • 2003
  • The new HVAC system to lower the conveyance energy and building height using IAV (Increasing Air Volume) technique is developed. IAV units which are equipped in each zone carry out air-conditioning and supply fresh air by induction of outdoor air in main duct. The design program which decides size of OAHU and IAV unit according to air conditioning load and fresh air demand of each zone is presented. The control system is developed to operate efficiently HVAC system and IAV unit, so that individual zone operation and well-deal with partial load and IAQ problem are possible. The new system is investigated in model building and makes more profit in conveyance energy, size of air conditioning facilities room and building height than VAV system. But in construction cost it is worse by about 15 per-centage.

Experimental Study on the Irradiation and Surface Sterilization Effect of Ultra Violet Ray in Air Conditioning System (공조시스템에서 UV Ray의 조사 및 표면살균성능에 관한 실험적 연구)

  • 홍진관
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.250-257
    • /
    • 2004
  • Recently, the use of UVC lamps inside building air-conditioning system has been increasing in both medical and nonmedical buildings for the control of environmental microorganisms. In the present study, irradiance performance test of UVC lamp was carried out and surface sterilization effect of UV ray was investigated by using UV ray irradiation experimental chamber and pilot system. Experimental results show that the effective irradiance of UVC lamp is strongly dependent on air velocity and temperature with exception of relative huminity in air-conditioning system. An individual microbiological kill effectiveness experiment also shows that the fractional kill of two microbiological samples such as E. Coli and Legionella is roughly the same as the estimated fractional kill in the case of chamber test and pilot system test.