• Title/Summary/Keyword: 공조방식

Search Result 120, Processing Time 0.023 seconds

새로운 공기조화방식(가변풍량방식)

  • Park, Yong-Han
    • Korean Architects
    • /
    • no.6 s.56
    • /
    • pp.45-52
    • /
    • 1973
  • 오늘날 건축에 있어서의 설비방식이 다각도로 발전되고 있으며 또 개발되고 있다. 현재 많이 채택되고 있는 방식중에 가변풍양방식이 있는데 이 가변풍양방식의 기본적인 방식을 소개하고자 일본 건축설비 1972년 6월호에 게재된 신일본공조(주)에 횡산정부씨의 글을 번역하였으니 이 분야 설비전문가와 건축사들에게 도움이 된다면 고맙게 생각한다.

  • PDF

Evaluation of Indoor Air Environment by Changing Diffuser Location and Air Temperature with Under Floor Air Conditioning System (바닥취출 및 흡입시스템 공조방식에서 취출조건 변경시 실내공기환경 평가)

  • Kim Se-hwan;Park Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.5
    • /
    • pp.397-403
    • /
    • 2005
  • The thermal comfort of occupants is directly related to several environmental factors such as velocity of air flow, turbulence intensity and temperature distribution of indoor air. The purpose of this study is to evaluate the indoor air flow and temperature distribution in office area using under-floor air-conditioning system (UFAC System) based on the results from physical measurements and to perform a Computer Fluid Dynamics (CFD) under the same condition of inlet and outlet as field measurement. The results from the CFD simulation are similar to those from the field measurement. The results show that UFAC system is provide proper indoor condition for occupants.

Ice Slurry 방식 빙축열시스템 개발동향

  • 한국생산기술연구원 냉동공조연구팀
    • 보일러설비
    • /
    • s.78
    • /
    • pp.100-104
    • /
    • 2000
  • 본 고에서는 향후 빙축열시스템의 주류를 이룰 것으로 예상되어 활발히 연구개발이 추진되고 있는 Ice Slurry 방식 빙축열시스템에 대하여, 현재까지 개발되었거나 개발중인 시스템들의 특징, 종류, 응용분야 등을 중심으로 한 기술개발 동향 및 향후 추진되어야 할 연구개발방향 등, Ice Slurry 방식 빙축열시스템 전반에 걸친 연구개발 현황과 향후 전망에 대하여 알아보았다.

  • PDF

Ice Slurry 방식 빙축열시스템 개발동향

  • 한국생산기술연구원 냉동공조연구팀
    • 보일러설비
    • /
    • s.80
    • /
    • pp.111-116
    • /
    • 2000
  • 본 고에서는 향후 빙축열시스템의 주류를 이룰 것으로 예상되어 활발히 연구개발이 추진되고 있는 Ice Slurry 방식 빙축열시스템에 대하여, 현재까지 개발되었거나 개발중인 시스템들의 특징, 종류, 응용분야 등을 중심으로 한 기술개발 동향 및 향후 추진되어야 할 연구개발방향 등, Ice Slurry 방식 빙축열시스템 전반에 걸친 연구개발 현황과 향후 전망에 대하여 알아보았다.

  • PDF

The Performance Analysis of a Return Air Bypass Air Conditioning System by a Simulator Experiment (실물실험에 의한 순환공기 바이패스 공조시스템의 성능분석)

  • 신현준;김보철;김정엽
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.130-135
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; outdoor air bypass, mixed air bypass and return air bypass system. Among bypass air conditioning systems, a return air bypass system is more effective than other two systems because it doesn't induce unconditioned outdoor air into conditioned room. The numerical study on the bypass air conditioning system shows this system can maintain indoor RH(Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. A simulator was built to compare results of a numerical experiment and those of a simulator experiment. The results of the simulator experiment was nearly same as those of the numerical experiment; when a design sensible load (the ratio of sensible load to total sensible load) was 70 percent (at this time, RSHF=0.7), indoor relative humidity (in case of both numerical experiments and simulator experiments) was maintained below 60% specified by ASHRAE STANDARD 62-1999. The bypass air conditioning system is expected to be applied to many buildings where the Percentage of latent loads or air change tate is high.

Application of CFD Simulation to Cooling System Design of Agricultural Products Processing Center Workplace (농산물산지유통센터 작업장의 냉방 설계를 위한 CFD 시뮬레이션 적용)

  • Kwon, Jin-Kyung;Lee, Sung-Hyun;Moon, Jong-Pil;Lee, Su-Jang;Kim, Keyong-Won
    • Journal of Bio-Environment Control
    • /
    • v.19 no.4
    • /
    • pp.195-202
    • /
    • 2010
  • Cooling air-conditioning of APC (Agricultural Products processing Center) workplace is important to improve the working environment in the summer season. As existing cooling systems for air-conditioning of whole workplace are inefficient because of their high equipment operating costs, relatively inexpensive cooling system is required. The objectives of this study were to simulate the thermal flow fields in APC workplace having the positive and negative pressure type fan and pad systems and spot cooling system by using CFD software (FLUENT, 6.2) and estimate the cooling effectiveness of respective cooling systems. The results showed that the negative pressure type fan and pad system was inappropriate for the present APC workplace because of excessive outside air influx from open gateway and the positive pressure type fan and pad system created relatively low temperature field but non-uniform velocity field at worker positions. The spot cooling system could supply cool air to worker positions with relatively constant air velocity and temperature.

가변풍량공조방식

  • 김영호
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.4 no.2
    • /
    • pp.129-136
    • /
    • 1975
  • PDF