• Title/Summary/Keyword: 공조방식

Search Result 120, Processing Time 0.023 seconds

A Study on Design Decision of Qualitative Design Factors in Selecting of HVAC Type for Building (건축물의 공조방식 선택과정에 있어서 질적 설계요소들의 디자인 결정방법에 관한 연구)

  • 우세진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.8
    • /
    • pp.762-769
    • /
    • 2004
  • Not only in building design but also in HVAC system design, it is important to ensure an objectivity in schematic design. In the study, the author suggested a method to make a logical decision for quality design factors a(footing the selection of HVAC type in initial design process, and to provide objective design values. Fuzzy theory, one of the theories describing in quantitative way the ambiguous-natured linguistic values, was used to determine the qualitative design factors of linguistic parameter nature. It was found that it has a potential as a method to determine a HVAC type satisfying the required values of qualitative design factors involved in selection of the system type. But this needs further studies to be settled in the selecting of HVAC type.

대공간 건축물에 대한 최적 공조, 환기방식

  • 김지성
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.12
    • /
    • pp.9-17
    • /
    • 2004
  • 건축물에서 대공간으로 분류되는 로비, 공장, 공연장, 체육관의 기류 및 열환경 특성을 살펴 보고, 최적의 공조 및 환기 시스템 선정 방법을 기술하였습니다.

  • PDF

Evaluation of Thermal Performance for Air-Barrier Air-conditioning System in Perimeter Zone by Scale Model Experiment and Simulation (모델실험 및 수치해석을 통한 페리미터존 에어배리어 공조방식웨 열성능 평가)

  • Ham Heung-Don;Park Byung-Yoon;Sohn Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.10
    • /
    • pp.947-955
    • /
    • 2005
  • For the purpose of evaluating the thermal performance for air-barrier air conditioning system in perimeter zone, two air-conditioning systems, conventional perimeter air-conditioning system and air-barrier system, are evaluated and compared by scale model experiment and simulation during cooling season. As a result, measurement shows that supply air velocity of 1 m/s in the upstream direction at perimeter is more effective. Air-barrier system could reduce the cooling energy by $10\sim20\%$ compared with conventional system. Numerical simulation was carried out considering solar effect for reliable result. This method has improved the accuracy of numerical simulation for the space affected by the solar radiation. Both measurement and simulation results show that supply air velocity of 1 m/s at perimeter is the most effective.

(A Simulation of Neural Networks Control for Building HVAC) (신경망을 이용한 건물 공조시스템의 최적제어 관한 연구)

  • Yuk, Sang-Jo;Yoo, Seung-Sun;Lee, Geuk
    • Journal of the Korea Computer Industry Society
    • /
    • v.3 no.9
    • /
    • pp.1199-1206
    • /
    • 2002
  • This study is to verify the application characteristics of PI control and to simulate the applicability of Neural Networks control HVAC TRNSYS program. Each performance of HVAC by PI control and by Neural Networks is compared. According to the result of simulation, Neural Networks control is favorably applicable than previous PI control for the variation of weather condition and systematic changes.

  • PDF

한국전력공사 신사옥건립 기계분야 기본설계사례

  • Eom, Tae-Yun;Lee, Seung-Ju;Lee, Byeong-Ju
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.40 no.6
    • /
    • pp.40-47
    • /
    • 2011
  • 지중축냉시스템, 흡수식히트펌프, 천장형복사패널+바닥급기 공조방식 등의 획기적 에너지절약 시스템을 반영한 한국전력공사 신사옥건립 기계분야 기본설계 사례를 소개하고자 한다.

  • PDF

Comparison of age of air and air change effectiveness between supply diffuser types (공조취출방식에 따른 공기의 나이 및 환기효율 비교)

  • Cho, D.W.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.1
    • /
    • pp.117-124
    • /
    • 1999
  • In this study, three different supply diffuser types(desktop, floor and ceiling) are compared in view of their ability to distribute supply air to the workstation breathing zone. The measurements on the age of air and the air change effectiveness using the tracer gas method are carried out to analyze the ventilation performance for provision of fresh air between the diffusers. The desktop diffuser type could deliver air directly to the occupants breathing zone with a high degree of effectiveness. The measured local air change effectiveness of the desktop diffuser in the breathing zone was usually 1.13 to 1.23 times greater than that of ceiling and floor diffusers. When the minimum outside air change rate as specified using ASHRAE Standard 62R is supplied with a desktop diffuser type, the volume of outside air can be reduced 13 to 23%, resulting in a commensurate in ventilation energy use.

  • PDF

Cooling Architecture Research of Rack Units for the IDC Power Efficiency (전산실 전력효율화를 위한 랙 단위 냉각 아키텍처 연구)

  • Tae, Hyo-Sik;Park, Koo-Rack;Kim, Dong-Hyun
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2015.07a
    • /
    • pp.183-184
    • /
    • 2015
  • 본 논문에서는 데이터 센터 내 전력 효율화에 기여할 수 있는 랙 단위 공조방식에 대하여 제안한다. 스마트 폰과 태블릿 등 모바일 디바이스의 확산으로 디지털 콘텐츠와 데이터가 폭발적으로 증가하면서 데이터 센터의 수는 연평균 30%이상 증가하고 있다. 따라서 데이터 센터 내 냉방장비 영역의 효율성을 증가시킬 필요성이 대두되고 있다. 본 연구는 데이터 센터의 냉각비용을 증가시키는 전력 사용량을 줄이고자 진행되었으며 3종류의 냉각 아키텍처 방식 중 랙 단위 아키텍처가 불필요한 냉각 전력 소비를 줄인다는 것을 확인하였다.

  • PDF