Shear Behavior of R.C. Beams according to Increase of Concrete Compressive Strength (철근콘크리트 보의 고강도화에 따른 전단거동에 관한 연구)

  • 윤영수
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.6
    • /
    • pp.190-198
    • /
    • 1994
  • Th~s paper presents the shear behavior in reinforced normal, medium and high strength con crete beams due to the Increase of concrete compressive strength. Twelve shear tests were con ducted on full scale beam speclrnerls havmg concrete compressive stlengths of 360, 670 and 873kg/$cm^2$. Different amounts of shear reinforcement as a variable were investigated according to ACI 318 89. The shear responses are discussed in terms of the shear capacity. the ductility and the reserved strength. The prediction and comparison with the test results are also presented.

An Evaluation on Toughness of Ductile Fiber Reinforced Cementitious Composite according to Thickness and restrained method (시험체 형상 및 시험방법에 따른 고인성 콘크리트의 인장특성 평가에 관한 연구)

  • Park, Yun-Mi;Kim, Young-Duck;Kim, Young-Bong;Jeong, Jae-Hong;Kim, Gyu-Yong;Kim, Moo-Han
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.469-472
    • /
    • 2008
  • As a general rule, concrete has higher compression strength than bending and toughness. but Ductile fiber reinforced cementitious composite has high toughness property owing to adding a large volume fiber. Therefore uniaxial tensile strength test is imperative to evaluate high toughness property of ductile fiber reinforced cementitious composite in comparison with general concrete test. but in testing compression strength, Result is different by factor of thickness, shape and edge condition. Uniaxial tensile strength test is affected by fiber's length and section area because of cementitious composite property and factor of fiber arrangement. This study evaluates toughness property of ductile fiber reinforced cementitious composite according to thickness and edge condition. The more thickness is thin, the more high performance by fiber arrangement

  • PDF

Characteristics for Reinforcement Corrosion and Chloride Ion Diffusion of High Volume Fly Ash Concrete (하이볼륨 플라이애시 콘크리트의 철근부식 및 염소이온 확산 특성)

  • Kwon, Soon-Oh;Bae, Su-Ho;Lee, Hyun-Jin;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.1
    • /
    • pp.34-39
    • /
    • 2014
  • The purpose of this experimental research is to evaluate the resistance of reinforcement corrosion and chloride ion penetration of high volume fly ash (HVFA) concrete. For this purpose, concrete test specimens were made for various strength level and replacement ratio of fly ash, and then compressive strength and diffusion coefficient for chloride ion of them were measured for 28, 91 and 182 days, respectively. Also, corrosion monitoring by half cell potential method was carried out for the made lollypop concrete test specimens to detect the time of corrosion initiation for reinforcement in concrete. As a result, it was observed from the test results that compressive strength of HVFA concrete was decreased with increasing replacement ratio of fly ash but long-term resistance against reinforcement corrosion and chloride ion penetration of that was increased.

Experiments for the Fatigue Behavior of High Strength Concrete (고강도 콘크리트의 피로거동에 관한 실험적 연구)

  • 김진근;김윤용
    • Magazine of the Korea Concrete Institute
    • /
    • v.5 no.4
    • /
    • pp.179-187
    • /
    • 1993
  • In thls study, cylindrical concrete specimens wth varlous strength levels were tested to lnves tlgate the fatigue behavlor of high strength concrete. Selected test variables welp cornpresslve strength with 4 levels(26 MIPa, 54 MPa, 82 MPa. 103 MPa) and maximum \tress wlth 4 levels (75% 80%, 85%, 95%). A total of 160 specimens(${\phi}100{\times}200mm$) were cdsted fol the test. l'he fatigue llfe was decreased for the hlgher strength concreate. R model fol S N, relationship con sidering the effect of compressive strength, was proposed. In addition, this model included the stram rate effect whlch was modified for the strength level. It was found that the ~rrecoverable stram of normal strength concretc3 was greater than that of high strength concrete However the strain ~ncrease per cycle of load was great for the highcr strength concrete.

Effect of Size Factor on Estimating Elastic Modulus of Disk-Shaped Concrete Specimen Using Impact Resonance Test (충격공진법을 이용한 콘크리트 원판 시편의 탄성계수 추정에 크기 인자가 미치는 영향)

  • Kim, Min-Suk;Son, Joeng Jin;Lee, Chang Joon;Chung, Chul-Woo
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.1
    • /
    • pp.11-22
    • /
    • 2023
  • In this work, a depth-by-depth evaluation on the deterioration of concrete is suggested by utilizing disk shaped concrete specimens. Dynamic elastic modulus of cylindrical concrete was measured using a free-free resonance column method and compared with dynamic elastic modulus of disk-shaped concrete measured by impulse excitation technique(IET) and impact resonance(IR). According to the results of the experiment, both IET and IR methods showed a smaller difference in dynamic elastic modulus with smaller deviation in data when thickness of the disk specimen was increased. This trend was more evident from dynamic elastic modulus measured by IR method compared to that measured by IET. Variation in data was also smaller with the IR result. To increase the accuracy of the data, it is recommended to use the IR method for disk specimen with a diameter of 100mm and a thickness of 25mm.

Resistance to Acid and Sulfate of Concrete Containing Mineral Admixtures (광물질 혼화재를 혼입한 콘크리트의 산 및 황산염 저항성)

  • Park, Jae-Im;Bae, Su-Ho;Lee, Kwang-Myong;Cha, Soo-Won
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.281-282
    • /
    • 2009
  • The purpose of this experimental research is to investigate the influence of mineral admixtures on the resistance to acid and sulfate. For this purpose, concrete specimens with types of mineral admixtures such as ground granulated blast-furnace slag, fly ash, and silica fume were made for water-binder ratios of 32% and 43%. It was observed from the test result that the resistance against acid and sulfate of the concretes containing mineral admixtures were much better than the case of plain concrete from immersion tests of 182 days.

  • PDF

Performance and Optimum Formulation of Corrosion Inhibiting Admixture (방청 혼화제의 최적 Formulation 및 성능연구)

  • Chun, Yong-Jin
    • Proceedings of the KAIS Fall Conference
    • /
    • 2007.05a
    • /
    • pp.267-269
    • /
    • 2007
  • 콘크리트 중의 철근이 염분에 의해 부식되는 것을 억제 또는 예방하고, 각종 부식 환경으로부터 구조물의 수명을 연장할 목적으로 사용되는 방청혼화제의 최적 formulation과 그에 대한 물성 및 성능 시험을 실시하였다. 철근 부식에 대한 방청 메카니즘의 이해와 방청 혼화제의 formulation에 따른 물성시험과 성능평가를 실시하여 최적 조건을 확립하였다. 성능평가는 콘크리트 공시체의 Slump, 공기량, 압축강도(3일, 7일, 28일) 측정과 함께 염수침지시험 동의 방청성능 평가를 실시하였다.

  • PDF

A Study on the Effect of Fire Heat on the Durability of Concrete Structures Repaired and Reinforced with Epoxy Resin (화열(火熱)이 에폭시수지로 보수·보강된 콘크리트 구조체의 내구성에 미치는 영향에 관한 연구)

  • Tai Kwan Cho
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.1
    • /
    • pp.138-145
    • /
    • 2023
  • Purpose: In accordance with the increase in the number of buildings repaired and reinforced following deterioration from when a fire occurs in a previously reinforced building, the impact on the structure after the fire is analyzed to establish standards for repair and reinforcement measures. Method: After curing for 28 days, the process was to measure the compressive strength and induce destruction through a compressor, repair and reinforce it with epoxy, and conduct a re-compressive strength test on some specimens after curing for 3 days to understand the degree of strength restoration. The rest of the repaired and reinforced specimens as well as the unrepaired and unreinforced specimens were then put into an oven and heated according to the temporal and temperate conditions listed below, and then the compressive strength was tested to estimate the impact of fire. Result: After reinforcing the yielded specimen with epoxy, the process was to then put it in an oven and heat it at different temperatures over time. It was found that there was a decrease in the strength of the reinforcement more than that of the actual specimen. Conclusion: Based on this, it was found that a building repaired and reinforced with epoxy resin is actually more dangerous than a general unrepaired building when it is damaged by fire, and thus, that it must be prepared for fire vulnerabilities.

A Study on the Estimation for the Guaranteed Strength and Construction Quality of the Combined High Flowing Concrete in Slurry Wall (지하연속벽용 병용계 고유동 콘크리트의 시공 품질 및 보증강도 평가에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.811-817
    • /
    • 2006
  • The primary purpose of this study is to estimate the guaranteed strength and construction quality of the combined high flowing concrete which is used in the slurry wall of underground LNG storage tank. The required compressive strength of this type of concrete become generally known as a non economical value because it is applied the high addition factor for variation coefficients and low reduction factor under water concrete. Therefore, after estimation of the construction quality and guaranteed strength in actual site work, this study is to propose a suitable equation to calculate the required compressive strength in order to improve its difference. Application results in actual site work are shown as followings. The optimum nix design proportion is selected that has water-cement ratio 51%, sand-aggregate ratio 48.8%, and replacement ratio 42.6% of lime stone powder by cement weight. Test results of slump flow as construction quality give average 616~634mm. 500mm flowing time and air content are satisfied with specifications in the rage of 6.3 seconds and 4.0% respectively. Results of strength test by standard curing mold show that average compressive strength is 49.9MPa, standard deviation and variation coefficients are low as 1.66MPa and 3.36%. Also test results by cored cylinder show that average compressive strength is 66.4MPa, standard deviation and variation coefficients are low as 3.64MPa and 5.48%. The guaranteed strength ratio between standard curing mold and cored cylinder show 1.23 and 1.32 in the flanks. It is shown that applied addition factor for variation coefficients and reduction factor under water concrete to calculate the required compressive strength is proved very conservative. Therefore, based on these results, it is proposed new equation having variation coefficients 7%, addition factor 1.13 and reduction factor 0.98 under water connote.