• Title/Summary/Keyword: 공동 주택

Search Result 2,629, Processing Time 0.026 seconds

A Study on Improving the Utilization of Biotope Area Ratio System Considering the Plant Growth Conditions (작물 생장조건을 고려한 생태면적률 제도 개선 방향)

  • Lee, Gunwon;Jeong, Yunnam;Ji, Seongkyun;Kim, Seiyong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.2
    • /
    • pp.1490-1499
    • /
    • 2015
  • The purpose of this study is to improve Biotope Area Ratio(BAR) systems used in the various fields. Recently, there has been increasing demand in urban agriculture as well as more residents cultivating farms on a small scale. However, there are few measures in terms of architecture and urban planning to respond to this trend. In this sense, this research is effective as it can respond to these demands by using BAR systems. Yet, the environmental indexes are not enough since BAR systems only take account of vegetation. Therefore, this study proposes an alternative way that includes the capacity factor of the plant growth by expanding the existing BAR systems. Thus, the study analyzes the complementary possibility of BAR systems, including elements of daylight, planting interval, area and soil depth with existing BAR elements.

A Study on the Assessment of the IAQ during Nightime (공동주택에서 취침 시 실내공기환경 평가에 관한 연구)

  • Kim, Dong-Gyu;Kim, Sam-Uell;Kim, Se-Hwan
    • KIEAE Journal
    • /
    • v.7 no.5
    • /
    • pp.93-98
    • /
    • 2007
  • Effort has been performed for latest 20 years to improve resident's comfort and indoor environment in building. And interest and effort to improve indoor air environment among various indoor environment elements have continuously increased since 1990s, because it is examined scientifically that various contaminants generated indoor affect human body. Specially, indoor air contaminants generated from apartments are those exhausted from resident's indoor environment, closing materials and household. Indoor air environment in buildings is different according to pollution degree, existence availability of pollution source, ventilation amount, and meteorology. It is known that other contaminants more than about 900 kinds generate according to a kind of work or action in a room. Specially, nowadays buildings are well insulated and confidentiality-centered for environment protection and economical side. So indoor air contaminants are generated from indoor air pollution sauces of unprepared ventilation, human body carbon dioxide emissions, and various building materials. when these are accumulated in long term human body, it is harmful to resident's health, but awareness for this is very insufficient. Because bedroom is space that people inhabit for a long time by unconscious state and indoor environment occupies important part for resident's health and quality of life at sleep, the actual condition of air quality is investigated, improvement countermeasure is considered, and ventilation amount is analyzed. In this study, putting case that the most longest stayed time is sleeping time when people inhabit in the apartment, the air quality according to volume of bedroom space at sleep was measured and analyzed, and the data acquired will be the basis for improvement on this.

Cost Analysis for Fire Protection on Structural Members of Residential Steel Building using Fire Engineering Design (내화설계법에 따른 철골조 아파트의 내화피복비용 연구)

  • Kwon, In-Kyu;Chung, Yeong-Jin
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.81-89
    • /
    • 2010
  • In general, fire resistance is determined through the building' uses and stories. But recently a fire engineering design that is done by the calculation of design fires from the fire cell and an evaluation of stabilities for structural behavior at fire condition have applied to almost of countries as a major alternative against a prescriptive fire design. To adopt and utilize the fire engineering design into Korea, at first, we evaluated structural stability of 21st stories steel residential building at fire condition through fire engineering design and secondly the fire protection cost was analyzed with fire engineering design method and the prescriptive one, respectively. No fire protection materials for satisfaction of building law at structural members such as columns and beams were needed and about 90 % of fire protection cost was saved.

Field Survey on the Construction Errors for the Members of Reinforced Concrete Structures (현장조사를 통한 철근콘크리트 구조 부재의 시공오차에 관한 연구)

  • Yoon, Sang-Chun;Jee, Nam-Yong;Choi, Ki-Bong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.3
    • /
    • pp.201-208
    • /
    • 2010
  • Information on the distribution characteristics of construction errors is very important to determine the member factors, which are to be introduced in a new Korean design code for reinforced concrete structures. The new design code, which is under development for reinforced concrete structures, is based on the performance design concept. The construction errors of reinforced concrete members are mainly caused by the firmness and dimensional accuracy of forms, the arranging condition of reinforcing bars, the pouring and compaction methods of concrete, the skills of field workers, and the experience of supervisors. To find out the construction errors of reinforced concrete structures already built in Korea, a field survey for cover thickness, effective depth of reinforcement, the thickness of slabs and walls, and the dimension of beams and columns has been performed. Based on the survey, which is the first time in Korea, the analysis results are presented. The measuring methods for the construction errors, which have been established through the laboratory tests, are also presented. In addition, the measured construction errors from the survey are compared with the allowable tolerances in the current domestic and foreign specifications.

A Study on the Establishment of a Collaboration Relationship between Prime and Subcontractors in Korean Construction Industry - Focused on the Gangwon Area - (건설업 원.하청 기업간 협력관계 구축에 관한 연구 -강원지역을 중심으로-)

  • Kim, Jin-Bong;Kim, Seon-Gyoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.3
    • /
    • pp.95-107
    • /
    • 2008
  • Recently, a size of the domestic construction industry Has been reduced rapidly, and its economic slump Has been continued with the government real estate stabilization and tax policies. Moreover, as the reconstruction of apartments that has been added high value to the construction companies has been on the stake of high risk with delays of reconstruction start and finance restriction policies, an uncertainty of the construction markets and the competitions between the construction companies has been increased. At this point, the establishment of a collaboration relationship between construction companies has been recognized as one of the methodologies to respond actively on these uncertainties and fierce competitions. A collaboration relationship between construction companies is based on the balanced cooperation relationship for surviving together, and should be maintained on the complement and specialized collaboration between big, middle and small contractors. This paper propose a model of practical collaboration relationship to cooperate together between prime and subcontractors in Korean construction companies based on the analysis of questionnaires to the collaboration status between general and subcontractors in the Gangwon area.

A Study on Multi-dimensional Poverty of Female Youth in Korea (우리나라 여성청년의 다차원적 빈곤에 관한 연구)

  • Yoo, Jiyoung
    • Journal of Digital Convergence
    • /
    • v.17 no.10
    • /
    • pp.85-91
    • /
    • 2019
  • Present study notes that youth poverty is not only an income deficit, but also a deficit in various dimensions of life such as housing, work and health deficit. Multidimensional poverty is measured by four dimensions: income, work, housing and health. The sample is a 2630 one-person household female youth pooled from the Korea Welfare Panel 10-Year Data. The analysis tool used SPSS statistical program, and the analysis framework was the deficiency rate by dimension, the correlation analysis between deficiency dimension, and the overlapping rate of N dimension poverty. As a result, women's youth in Korea had higher deficit rate in terms of work and housing than other dimensions, and the proportion of women youth who were both poor in work and housing at the same time was also relatively higher than in other cases. Based on these results, this study proposes the construction of customized job services, job matching with small and medium-sized enterprises and allocation of one young woman's household among the targets of long-term chartered housing. Female youth's sharing-economy association should be considered as alternatives.

Study of Energy Cost for Performing Flush-out in Newly Constructed Multi-residential Buildings during Winter Season (겨울철 신축 공동주택의 플러쉬아웃 시행 시 난방비용에 관한 연구)

  • Lee, Ki Yong;Kim, Kee Han;Park, Jun-Seok
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.3
    • /
    • pp.110-114
    • /
    • 2016
  • Newly constructed multi-residential buildings with more than 500 households should be flushed out indoor contaminants using a mechanical ventilation system or large fans after the completion of construction and prior to occupancy by the Heath-friendly Housing Construction Standards since 2014. In addition, the standard recommends to maintain indoor temperature over $16^{\circ}C$ and relative humidity below 60% while performing the flush-out. However, it is difficult to maintain these recommended indoor conditions, especially during winter season because additional energy cost is needed for space heating. Therefore, in this study, additional energy cost including heating and ventilation energy cost in multi-residential household for flush-out during winter season was estimated using building energy simulation program called EnergyPlus. Additional energy cost according to various conditions for performing flush-out (such as performance period, ventilation rate, and heating set-point temperature) was analyzed. Based on the results of the energy simulation, the energy cost was estimated to be ranged from 14,625 to 29,452\/household in Incheon city and from 3,521 to 26,268\/household in Gwangju City. There was no significant change in energy cost according to the performing terms of flush-out between Incheon and Gwangju City.

Theoretical Analysis on the Applications of the Double-Floor Ondol System (이중 바닥 온돌 시스템의 응용에 관한 이론적 분석)

  • Choi, Won-Ki;Lee, Kang-Young;Lee, Hyun-Geun;Suh, Seung-Jik
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.5
    • /
    • pp.355-363
    • /
    • 2007
  • The Korean traditional 'Ondol' system has been a target for innovation to meet the requirements of sustainable domestic building and low carbon emission energy utilization. Simulation techniques provide designers and researchers with powerful tools to predict heating load and thermal behaviour of Ondol systems installed in various contexts. However, there are few studies on Ondol models, especially associated with multi-stories buildings of which type covers about 50% of Korean housing stock. In this study, we analyzed the double floor Ondol system on the multi-stories buildings using the ESP-r program. On the basis of the double floor Ondol system, we suggested the new modelling method that is composed of the Vent zone and Ondol zone. Using the this model, sensitivity analysis was carried out to refine the applicability of the model taking account of control conditions, constructions, air change and air flow network method and CFD analysis using the FLUENT. The air layer has enough temperature to use in heating zone. It is suggested that the simplicity of the model will allow building designers and mechanical engineers easily to implement scenario-based assessments of design options as well as control strategies. Later, we will simulate the real buildings and analyze the air distributions using the Fluent according to the various conditions.

Analysis of Energy Saving Effect of the Residential BESS Connected to the Balcony-PV in Apartment Houses (공동주택 발코니 PV 연계 가정용 BESS의 에너지 절감 효과 분석)

  • Kim, Cha-Nyeon;Eum, Ji-Young;Kim, Yong-Ki
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.3
    • /
    • pp.21-31
    • /
    • 2020
  • The government mandates gradually zero energy building and Photovoltaic power generation systems installed in buildings are emerging as the most realistic alternative to increase the independence rate of building energy. In this study, we propose a method to reduce the power consumption of households by increasing the PV capacity of balconies and applying the method used the charged electric power stored in batteries after sunset. In order to evaluate the electric power energy savings of the residential BESS, a balcony PV 1.2 kW and a battery pack 2 kWh were installed for 9 houses in 4 apartments in Seoul and Gyeonggi-do. The BESS is charged when the balcony PV is generated electric power, and when solar power generation is finished, it supplies power to the electric appliances connected to the load. As a result of installing the solar PV module 1.2 kW and 2 kWh class BESS for 3 households located in Seoul and Gyeonggi-do, the average electric power consumption saving rate was 40%. The reduction in electricity consumption in the case of zero generation surplus power by maximizing the utilization rate of BESS has been improved to about 53%. Therefore, in order to increase the self-sufficiency rate of electric energy in apartment houses, it is effective to increase the solar photovoltaic capacity of the balcony and apply the residential BESS. In the future, it is believed that the balcony PV and home BESS will play a key role in achieving mandatory zero-energy housing.

Study on the Design of Butyl Rubber Compound and Noise Reduction System for Sound Insulation (소음 차단 성능 향상을 위한 부틸 탄성체 배합 및 진동제어 시스템 디자인 연구)

  • Kim, Won-Taek;Chung, Kyung-Ho
    • Elastomers and Composites
    • /
    • v.49 no.2
    • /
    • pp.95-102
    • /
    • 2014
  • The noise between floors of apartment has been hot issue nowadays. In order to improve the noise insulation performance, we proposed the antivibration rubber system which can be applied to the floor system for sound insulation. Among various types of elastomer, butyl rubber showed the good aging characteristic, low rebound resilience and high damping factor. Thus, the butyl rubber was selected as a basic rubber for antivibration rubber system. The effects of type and loading amounts of carbon black on antivibration properties of butyl rubber were studied. The increase of surface area and the content of carbon black resulted in high bound rubber fraction, high mechanical property, low rebound resilience, and high damping factor of butyl rubber. Based on the results of this study, the new antivibration rubber was prepared and applied to the floor system for sound insulation. The impact sounds of floor system proposed in this study were 40 dB and 43 dB in cases of light weight and heavy weight impact sound, respectively.