• Title/Summary/Keyword: 공동 주택

Search Result 2,629, Processing Time 0.023 seconds

Spatial Relations of the Urban Expansion Intensity and Flooded Buildings (도시확장강도와 건물침수의 공간적 관계성)

  • Kang, Sang Jun;Kwon, Tae Jung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.4
    • /
    • pp.759-764
    • /
    • 2017
  • The paper is intended to explore the spatial relations between flooded buildings and urban expansion phenomena by employing urban expansion intensity index and hotspot analysis methods for the case of Gangneung. Two major results are as followed; first, flooding susceptible areas are found in the regions where the highly intense development occurs within a short period of time, so called pseudo-urbanization. Second, less flooded buildings exist in old towns where it is believed that there is the lack of urban infrastructure services. This study indicates the possibility that the highly intense development and pseudo-urbanization with a relatively short time period relate to flooded building events. In addition, the possibility leads to another issue that new developments might be increasing the flooding vulnerability worse than before, particularly, to the adjacent old towns. For the better understanding, it is desirable to have further related case studies in the near future.

A study on the Occupants' Apprasials of Newly Consturcted Apartment (신축 공동주택의 주거환경에 관한 입주자 평가)

  • 임인순
    • Journal of the Korean housing association
    • /
    • v.4 no.2
    • /
    • pp.73-83
    • /
    • 1993
  • Recently, large APT complexes are newly constructed in Taegu city and among them, large APT complexes aggegate densly espically in Weolsung and Jisan complexes of Dalsuh-gu and Susung-gu districts. The purpose of this thesis is to perform occupants' apprasials about residential environment on the housewifes residing at new constructed APT who seem tn have different apprasials on the residential environment by the zones. The results of the investigations are as follows. 1. House possessed type and house sire got elevated in comparison with them before shifting residence in respect to residential property and it was revealed they moved to short distance in the change of their lands. And most occupants could choose their houses by looting-out and there's some difference in the choice motive according to the zones. 2. As a result of studying the relation between demographic and residential properties, there were deep differe-nces in the Possessed house type before move, possessed house size after move, preferenti-al degree of house and move plan. 3. In the degree of satisfaction on residential environment, the result was high in the order of heating facilities, water-supply and draining facilities and lighting and was low in the order of room's size, interior decoration and soundproofin. According to zones, there was a great difference in the items of room's size, privacy, heating facilities, securi-ty from calamity, ventilation, convenience of traffic and school group and facilities for extracurricular activities and the degree of satisfaction was high in Jisan zone in othe items except for room's size and heating facilities. 4. In the tenants' apprasials on tile inside and outside spaces of the zones, important factors were "Cultural Institutions", "Green Areas", "Level of Welfare Facilities" and "Utility degree of welfare facilities" and in the classification of important factors according to the zones, the first and the third factors were changed each other. I think this is because they attached importance to somethings dissatisfied in present circumstances.

  • PDF

Practitioners' Awareness of Planning Features for Environment-Friendly Apartment unit (공동주택 단위주거의 친환경 계획요소에 대한 전문가 의식조사)

  • Kwon, O-Jin;Lee, Yeun-Sook
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.11-18
    • /
    • 2003
  • The purpose of this study was to find out awareness of the environment-friendly planning elements for residential unit space among practitioners. The respondents in this questionnaire survey were 140 practitioners in architecture and interior design field. The major findings of this study were as follows; most of the respondents were aware of the impact of indoor built environment on residents' wellness. In addition, the survey respondents viewed that the factors for planning environment-friendly high-rise apartments were represented by gardening and energy-saving while their perception on the concept excluded comprehensive components affecting residents' life quality. Over 50% of respondents had an experience of applying environment-friendly planning elements in their works, and high frequency appeared on the general planning elements which had been applied special awareness as pro-environmental features. The respondents considered environment-friendly planning elements as important. Specially, space planning and system were considered more likely important in interior design field. In application of environment-friendly planning elements, cost, lack of consumers' awareness of and underdevelopment of environment-friendly materials were of concern. Therefore, the consumer's cognition needs to be improved for wide application about environment-friendly planning element, and then consumers are willing to pay additional construction cost of environment-friendly apartments. At the same time, the current practice that housing developers pass the additional cost on to residents needs to be changed. Then, the quality of life in high-rise residential settings can be improved. More importantly, the exchange and development of the reliable information on environment-friendly planning elements need to be made, and technical support and long-term policy for the development are required. This research showed current status of knowledge and practice in sustainable planning of unit apartment and proved basic information for future direction.

The Field Measurement of Airtightness in the Apartment Buildings (신축공동주택의 기밀성능 실측에 관한 연구)

  • Park, Won seok;Yoon, Jae Ock
    • KIEAE Journal
    • /
    • v.3 no.3
    • /
    • pp.43-50
    • /
    • 2003
  • Nowdays the apartment is a main type of modernized residential buildings. According to the improvement of construction techniques and functions of windows and doors, recent apartments are enhanced air tightness of windows, doors and building envelopes. As Infiltration is decreased and natural ventilation is reduced, energy could be saved in winter. However, indoor air quality is bad. The air Infiltration of a building could be enlarged by physical actions, such as building designs, constructions and reduction of air tightness which is caused by aging. This research analyzes and measures with KNS-4000P (Sapporo air tightness measurement) the air tightness of the high rise apartments which is recently constructed and not occupied yet. With depressurization method, the KNS-4000 installed on the window and the indoor air-leakage was measured. At that time, Air come out from the edge of the windows and doors because of the pressure differences between indoor and outdoor. We measure the amount of the air as effective air leakage areas. This method of depressurization takes less time to measure than other methods and is less affected from other conditions. We measured infiltration of total 56 household, 29 households S apartment (total floor area : $64.42m^2$) in Balan and 29 households D apartment(total floor area : $78.21m^2$) in Chonan. As a result of the field measurements at October 2003, normalized leakage area of D apartment in Cheonan was $2.05cm^2/m^2{\sim}3.49cm^2/m^2$ (average: $2.77cm^2/m^2$) and normalized leakage area of S apartment in Balan is $1.23cm^2/m^2{\sim}1.68cm^2/m^2$ (average: $1.5cm^2/m^2$).

Characteristic Analysis of Utilization of Security Deposit for Repairing Defects Using Statistical Analysis (통계분석을 이용한 공동주택 하자보수보증금 특성 분석)

  • Seo, Deok-Seok;Lee, Ung-Kyun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.15 no.2
    • /
    • pp.209-215
    • /
    • 2015
  • This study was conducted to analyze the actual utilization rate of the deposit for defect repair of apartment complexes and its influential factors. We analyzed the data on enforced defect deposit cases by using one-sample t-test, Pearson's correlation analysis, and simple linear regression analysis. The difference between the deposit amount specified and the enforcement amount actually disbursed was found to about 0.51%. The change rates for short-term costs amounted approximately to $839KRW/m^2$ and 130,000 KRW/household per year, and those for long-term costs were $647KRW/m^2$ and 123,207 KRW/household per year. The results warrant the need for further research on establishing a deposit amount based on actual statistical data.

Development of Quantity based Base Period Price Index(QBPPI) to calculate Construction Cost Index (건설공사비지수의 산정을 위한 수량기반 기준시점 가격지수의 개발)

  • Park, Sung-Chul;Koo, Kyo-Jin;Hyun, Chang-Taek
    • Korean Journal of Construction Engineering and Management
    • /
    • v.7 no.5
    • /
    • pp.77-84
    • /
    • 2006
  • Indexes have played an important role as a economic indicator or performance indicator in many industries for a long time. In construction industry, indexes, or Construction Cost Index(CCI), have been used to compensate for the gap of time in Estimate Using the Historical Cost Data from Feb. 2004. CCI is composed of index formula and resources. Existing literatures had used Laspyeres Index as a index formula. And, Leontief table, the bills of quantities, and information of price surveyor were used as a resource. When applying Laspyeres formula and the resources to calculating the CCI, the problems such as double application of price fluctuation, calculating the incorrect weights, may be generated. This paper analyzed the existing economic relevant indexes as well as Laspyeres formula. Thus, feasibility of them was analyzed using three practical cases of apartments. And then, Quantity based Base Period Price Index(QBPPI) was developed to consider the characteristics of construction more accurately.

A Comparative Study on Domestic and International Evaluation Criteria of Commissioning for Sustainable Building Certification (국내외 녹색건축인증에서의 커미셔닝 평가기준에 대한 비교 연구)

  • Jeong, Dahun;Jung, Chanwoo
    • Korean Journal of Construction Engineering and Management
    • /
    • v.18 no.1
    • /
    • pp.27-36
    • /
    • 2017
  • Ministry of Land, Infrastructure and Transport established Heating and cooling energy conservation plan of apartment for 2017, reducing 90% compared to energy consumption of 1990. Also, at 2015 United Nations Climate Change Conference, the Ministry announced to reduce 37% of estimated $CO^2$ emission(850 million ton) at 2030. To satisfy this, it is urgent to reduce $CO^2$ emission due to the building, which takes majority amount of total $CO^2$ emission, and public interest for the commissioning of intensified building performance is uprising. However, the building commissioning at construction is not enacted, and not activated due to the lackness of promotion and will of general contractor. Furthermore, commissioning is not mandatory for obtaining G-SEED certification. Therefore, this paper describes effectiveness of commissioning with comparison of commissioning evaluation criteria of G-SEED with LEED and BREEAM, to propose making commissioning as mandatory process and drive changes in perception among stakeholders for activation of domestic building commissioning.

LS-SVM Based Modeling of Winter Time Apartment Hot Water Supply Load in District Heating System (지역난방 동절기 공동주택 온수급탕부하의 LS-SVM 기반 모델링)

  • Park, Young Chil
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.9
    • /
    • pp.355-360
    • /
    • 2016
  • Continuing to the modeling of heating load, this paper, as the second part of consecutive works, presents LS-SVM (least square support vector machine) based model of winter time apartment hot water supply load in a district heating system, so as to be used in prediction of heating energy usage. Similar, but more severely, to heating load, hot water supply load varies in highly nonlinear manner. Such nonlinearity makes analytical model of it hardly exist in the literatures. LS-SVM is known as a good modeling tool for the system, especially for the nonlinear system depended by many independent factors. We collect 26,208 data of hot water supply load over a 13-week period in winter time, from 12 heat exchangers in seven different apartments. Then part of the collected data were used to construct LS-SVM based model and the rest of those were used to test the formed model accuracy. In modeling, we first constructed the model of district heating system's hot water supply load, using the unit heating area's hot water supply load of seven apartments. Such model will be used to estimate the total hot water supply load of which the district heating system needs to provide. Then the individual apartment hot water supply load model is also formed, which can be used to predict and to control the energy consumption of the individual apartment. The results obtained show that the total hot water supply load, which will be provided by the district heating system in winter time, can be predicted within 10% in MAPE (mean absolute percentage error). Also the individual apartment models can predict the individual apartment energy consumption for hot water supply load within 10% ~ 20% in MAPE.

A Study on the Application of Small Wind Power System in Apartment Housing (공동주택에서의 소형풍력발전시스템 적용에 관한 연구)

  • Park, Jin-Chul;Kyung, Nam-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.2
    • /
    • pp.21-34
    • /
    • 2003
  • This study aims to present the applicability of wind turbine generator system to urban buildings for the utilization of clean renewable energy. The results are as follows; According to the wind resource analysis, it has been found that small sized wind power system can be viable for buildings application due to the amplification of wind velocity around buildings or building clusters, in spite of low mean velocity of 2-3m/s in Seoul and Kyunggi urban areas. But planners must perform micrositing analysis around building so that wind turbine can be located at high velocity zones. The system must be designed to avoid obstacles preventing prevailing wind in buildings. It should be recognized that wind speeds are changing depending on the height and length from buildings. The wind power system can be used as a symbol of landmark which shows a sustainable architecture from the scenary Itself A case study for apartment building in urban showed that wind power systems can be applicable in two kinds of place, rooftops and ground levels. Especially, the wind power systems must be carefully positioned so that wind resources do not decrease when it is installed at ground levels. and according to life cycle cost analysis, adaption of new small win4 power systems to buildings were proved to produce a profit if it is considered the expense of environment improvement and the wind speed increasing according to rise of building height. This research will ultimately achieve green architecture that preserves nature and at the same time provides pleasant environment to humans, and will play a great role in establishing the environment-preserving sustainable architecture of the 21th century.

Numerical Study on Air Egress Velocity in Vestibule Pressurization System : Characteristics of Air Flow in the Vestibule with Multiple Fire Doors in an Apartment Building (부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구: 공동주택 부속실내에 다수 출입문의 존재시 기류특성)

  • Seo, Chanwon;Shin, Weon Gyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.30-36
    • /
    • 2014
  • The pressurized smoke control system in the vestibule is important for fire safety in buildings because it is concerned with egress time of people and the safety of fire fighters. The vestibule pressurization system can prevent smoke from entering the vestibule using differential pressure when fire doors are closed and using the egress velocity when fire doors are open. Air supplying units in the vestibule need to be arranged by taking account of the location of doors and the volume of the vestibule in order to assure the uniform air egress velocity through a fire door when it is open. In this study, computational fluid dynamics (CFD) simulations were conducted for the vestibule where multiple doors are installed and it was found that the reverse flow occurs when the damper position in vestibule is not appropriate.