• Title/Summary/Keyword: 공기 제어

Search Result 925, Processing Time 0.023 seconds

Development of an Automated Control System for Bioreactor using the Plant Tissue Culture (식물조직배양용 바이오리액터의 농도제어 시스템 개발)

  • Chung, Seok-Hyun;No, Daehyun;Kang, Changho;Kang, Sukwon;Han, Bong-Hee;Lee, Gee-Myung;Na, Young-Sun
    • Journal of Plant Biotechnology
    • /
    • v.31 no.4
    • /
    • pp.307-312
    • /
    • 2004
  • The bioreactor system for the large-scale plant tissue culture was developed to control the pH concentration and DO (dissolved oxygen), and air flowrate. The system controlling the proper air flow rate for each bulblet growth stage and monitoring the contamination of bioreactor using the pH change was controled by computer program. For the uniform bulblet distribution in bioreactor, the proper air flow rate was 300 cc/min at the beginning of bulblet culture, 400 cc/min after 20 days, 500 cc/min after 40 days, 600 cc/min after 60days, and 700 cc/min after 80 days. It was possible to maintain the pH concentration within 5.5$\pm$0.5 during the culture by control system of bioreactor.

Development Of Active Vibration Isolation System Using Fuzzy Method (퍼지 방법을 이용한 능동 방진 시스템의 개발)

  • Yang, Xun;An, Chae-Hun;Jin, Kyoung-Bog;Rim, Kyung-Hwa
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.731-736
    • /
    • 2007
  • Vibration isolation equipments are mostly required in precise measurement and manufacturing system. Among all the vibration isolation system, air-spring is the most widely used equipment because of low resonant frequency and high damping ratio. In this study, Takagi-Sugeno fuzzy method is used to design an active vibration isolation system using air-spring, and compared the fuzzy method with passive control method and PID control method. Due to the non-linearity characteristics of air-spring, fuzzy controller was verified to be the most effective both in simulation and experiment.

  • PDF

Design and Manufacture of the air mixing system for supersonic ground test facility (초음속 지상추진시험설비의 공기 혼합시스템 설계 및 제작)

  • Lee, Yagn-Ji;Kang, Sang-Hun;Yang, Soo-Seok
    • Aerospace Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.40-48
    • /
    • 2008
  • Air mixing system which is composed of air pressure control system, hot pipe system and air mixer, is the facility for mixing hot air($1000^{\circ}C$, 10kg/s) from storage air heater (SAH) and decompressed air($20^{\circ}C$, 15kg/s) from high pressure air supply system. Air pressure control system reduce the pressure of the air, from 32MPa to 3.5 MPa and supply the decompressed air to air mixer. The hot pipe system supply hot air from SAH to air mixer which mix hot with the decompressed air from air pressure control system. Fully mixed air flow rate is 25kg/s and mixed temperature is up to $400^{\circ}C$. So, we can expand the operating envelop of the supersonic ground test facility to low Mach number and low altitude region.

  • PDF

An Application of k-$\varepsilon$ Turbulence Model to Predict How a Rectangular Obstacle with Heat Flux Affects Air Flow in An Experimental Animal House (실험축사의 공기유동예측을 위한 k-$\varepsilon$ 난류모형 적용)

  • Choi, Hong-Lim;Kim, Hyeon-Tae
    • Journal of Bio-Environment Control
    • /
    • v.1 no.1
    • /
    • pp.72-83
    • /
    • 1992
  • 우리 나라 축사는 생산효율 제고를 위하여 대형화, 밀폐화, 고밀도화, 자동화 경향이 뚜렷하다. 대형의 밀폐된 고밀도 축사는 쾌적한 실내환경을 전제로 하기 때문에 기계적으로 실내환경을 적절히 제어하지 않으면 안된다. 제한된 공간에 먼지, 병원성 미생물, 유해기체, 수분이나 열의 과도한 집적은 생산과 재생산효율에 심각한 영향을 미친다. 그러므로 축사내 생산주체인 가축과 작업인이 쾌적한 실내환경에서 생산활동을 할 수 있도록 열적, 화학적/생물학적 환경을 물리적으로 제어하지 않으면 안된다. 본 연구는 실험축사내 가축이 일정한 열을 발생할 때 실내공기의 유동형태를 예측하기 위해서 수행하였다. 이 연구의 결과를 실내환경제어를 위한 환기시스템 책략 개발의 기초자료로 활용할 수 있다. 실험축사내의 공기유동을 예측하기 위해 Body-Fitted Coordinate(BFC)의 격자배열과 k-$\varepsilon$ 난류모형 및 SIMPLE계열 solution scheme을 사용하였으며, 예측의 유효성 검정은 Boon(1978)의 실험결과를 이용하였다. 예측한 공기유동의 형태와 실험한 공기유동의 형태를 비교한 결과 대체로 만족할만한 결과를 얻었다. 그러나 유입공기의 온도가 1$0^{\circ}C$인 경우의 공기유동은 실험유동형태와 약간의 차이가 있었다. 즉, 실험에서는 수평슬롯으로 유입 된 공기가 바로 아래로 굴절되어 유동하였으나, 예측의 결과는 일정 거리로 수평방향으로 유동하다가 아래로 굴절하였다. 이런 유동의 차이는 k-$\varepsilon$ 난류모형 자체가 경험적으로 부력에 민감하게 반응않는 결함이 원인이 될 수도 있으며, 실험의 부적절한 수행이 원인이 될 수도 있다. 이 유동의 경우 Reynolds 수가 3,000정도의 난류이며, 완전발달유동 (fully-developed flow)이므로 관성력 (inertia force)이 부력 (buoyancy force)보다 커, 일정거리 수평으로 유동하다가 아래로 굴절할 수도 있기 때문이다. 앞으로 이를 규명하기 위한 보다 깊이 있는 연구가 이루어져야 할 것이다.

  • PDF