• Title/Summary/Keyword: 공기 제어

Search Result 923, Processing Time 0.029 seconds

뉴스광장

  • Korea Boiler Engineering Association
    • 보일러설비
    • /
    • no.12 s.155
    • /
    • pp.92-103
    • /
    • 2006
  • PDF

A Study on Energy Saving Effect from Automatic Control of Air Flowrate and Estimation of Optimal DO Concentration in Oxic Reactor of Wastewater Treatment Plant (하수처리장의 포기조 최적 DO 농도 산정 및 공기송풍량 자동제어를 통한 에너지 절감 효과 도출)

  • Kim, Min Han;Ji, Seung Hee;Jang, Jung Hee
    • Journal of Energy Engineering
    • /
    • v.23 no.2
    • /
    • pp.49-56
    • /
    • 2014
  • It is important to keep stable effluent water quality and minimize operation cost in biological wastewater treatment plant. However, the optimal operation is difficult because of the change of influent flow rate and concentrations, the nonlinear dynamics of microbiology growth rate and other environmental factors. Therefore, many wastewater treatment plants are operated for much more redundant oxygen or chemical dosing than the necessary. In this study, the optimal control scheme for dissolved oxygen (DO) is suggested to prevent over-aeration and the reduction of the electric cost in plant operation while maintaining the dissolved oxygen (DO) concentration for the metabolism of microorganisms in oxic reactor. For optimal control, The oxygen uptake rate (OUR) is realtime measured for the identification of influent characterization and the identification of microorganisms' oxygen requirement in oxic reactor. Optimal DO seT-Point needed for the microorganism is suggested based on real time measurement of oxygen uptake of microorganism and the control of air blower. Therefore, both stable effluent quality and minimization of electric cost are satisfied with a suggested optimal setpoint decision system by providing the necessary oxygen supply requirement to the microorganisms coping with the variations of influent loading.

Study of improvement control logic about unit master control(UMC) (Unit master control(UMC) 제어로직 개선에 관한 연구)

  • Park, Doo-Yong;Lim, Gyun-Pyo
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1707_1708
    • /
    • 2009
  • Unit master control(UMC)는 발전소의 요구 부하신호를 설정하는 최상위의 제어레벨이며 UMC의 설정값은 자동급전 지령신호(Automatic Dispatch System : ADS) 또는 운전원이 설정하는 값에 따라 보일러 및 터빈 Master에 Unit 요구 신호를 출력하여 하위제어 레벨인 공기, 연료, 급수 등을 조절할 수 있는 기기에 Unit 부하 요구 신호(Unit Load Demand : ULD)에 따라 제어 되도록 하는 방법으로서, Unit 목표부하 설정, Unit 목표부하 상/하한 제한, 목표부하 변화율 제한, 주파수 보정, Runback/Rundown/ Runup, 보일러 및 터빈 Demand 신호생성의 기능을 가지고 있다.

  • PDF

퍼지제어 시스템을 위한 마이크로컴퓨터 지원설계

  • 주해호;이재원;박창선
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1992.10a
    • /
    • pp.187-191
    • /
    • 1992
  • 본 연구에서 퍼지제어 시스템 설계를 위한 마이크로 컴퓨터 지원 설계 기법과 프로그램 FCS 를 개발하였다. 이 프로그램은 IBM-PC 호환기종 (80386,804860) 에 사용되는 Turbo-C 언어를 사용하였고, Borland C $^{++}$ 2.0 컴파일러를 사용하였다. 제어시스템의 각 요소를 모듈화 하여 동특성을 차분 방정식으로 표시하여 사용자가 쉽게 대치할 수 있도록 서브루틴화 하였다. 퍼지제어 규칙의 최적조건, 퍼지 입출력 변수의 최적조건, D/A 및 A/D 변환기의 최적 비트수, 최적 샘플링 시간을 결정 할 수 있다. 공기예열 시스템을 예로서 이 프로그램을 이용하여 설계하였다.