• Title/Summary/Keyword: 공기 정화기

Search Result 88, Processing Time 0.036 seconds

Numerical Simulation of Flows inside the Various Rooms for Performance Assessment of Air Cleaning System (공기청정 시스템 성능예측을 위한 실내 유동현상에 관한 수치모사)

  • 손덕영;이두환;길재흥;최윤호;김동현
    • Journal of Energy Engineering
    • /
    • v.11 no.4
    • /
    • pp.306-316
    • /
    • 2002
  • ln this paper, flowfields inside the various rooms have been investigated. A storage room, a liv-ingroom with a kitchen in an apartment, and a hospital room are considered in the present calculations. In all cases, it was found that the average of air change rate is. similar to that of perfect mixing assumption and the location of air purifier has little effects on the average air change rate. Detailed local air concentrations show that there are regions where air is not quite purified because of non-uniform circulation of air flow. The location of air purifier has great effects on this behavior.

A study on the photocatalyst filter design using UV-C (UV-C를 이용한 광촉매 필터 디자인에 관한 연구)

  • Han, Sang Yun;Kang, Seung Min
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.29 no.6
    • /
    • pp.276-282
    • /
    • 2019
  • The purpose of this study was to analyze the structure of general filter using ultrafine filter (Profilter), dust collector filter, HEPA (HAPA-High Efficiency Particulate Air) filter, deodorized filters, etc. of air purifiers and to study new types of purified filters that can improve ultrafine dust, harmful gases, and sterilization cleanup performance. The study was also conducted by adding photocatalyst filters to the existing step-by-step filtration filter types, which were proposed in the design three coupling structure filters of the left and right UV-LED installation frames and the photocatalyst coating honeycomb frame. Future research is needed on the effect of photocatalyst filters. This study was to investigate the application and structure of photocatalyst filters to air purifiers.

A Study on the Operational Variables of the UV-TiO$_2$ Based Photocatalytic Air Cleaning System (UV-TiO$_2$ 광촉매 기반의 공기 정화 시스템의 운전조건에 대한 연구)

  • Han, Chang-Seok;Chang, Hyuk-Sang
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.3
    • /
    • pp.293-301
    • /
    • 2008
  • A study on the operational variables of the UV-TiO$_2$ based photocatalytic air cleaning system was tried. In this study, to examine effects as various air cleaning system conditions, a duct-type reactor was made, and TiO$_2$ was immobilized on a stainless mesh. Benzene was chosen as a target compound. Removal experiments for benzene were done under different initial benzene concentration, air velocity, TiO$_2$ loading, area coated TiO$_2$ as the same TiO$_2$ loading, and UV light intensity conditions. During the experiments, relative humidity was 55%, and reactor temperature was 45$^{\circ}C$. As a result, the photocatalytic degradation of benzene decreased as the inlet concentration increased. But the photocatalytic degradation increased as the concentration boundary layer thickness, amount of TiO$_2$, area coated TiO$_2$ as the same amount of TiO$_2$, and UV light intensity increased. Based on results of current study, they can be applied to the design of air cleaning system over low level VOCs in the indoor air.

광촉매 기술과 연구 동향

  • Ryu, Jeong-Ho;Park, Dong-Su
    • 기계와재료
    • /
    • v.21 no.2
    • /
    • pp.84-97
    • /
    • 2009
  • 현재 날로 심각해 지는 환경오염문제와 에너지 문제로 인하여 광촉매 기술이 하나의 대안으로 떠오르고 있다. 1970년대 초 일본에서 시작된 광촉매 관련 연구 개발은 90년대와 2000년대를 거쳐 오면서 다양한 상업화 과정을 시도하고 있고, 그 활용 가치가 높아 지고 있다. 광촉매 응용 기술은 일상생활에서 사용하는 각종 공기정화기, 살균기 등의 제품부터 산업계와 도시의 환경개선을 위한 수처리장치등의 적용시장이 점차로 증가하고 있다. 최근 가시광 반응 광촉매, 광촉매 고정화기술 등의 연구개발과 제품 개발이 학계와 기업을 통하여 활발히 진행되고 있으며, 이는 국가 경쟁력을 높이게 됨과 동시에 쾌적한 환경을 만드는데 큰 도움이 될 것으로 기대된다.

  • PDF

The Impact of Negative Ions and Plant Volume Changes in Space on Fine Dust Purification in the Atmosphere (공기 중 음이온과 공간 내 식물용적 변화가 미세먼지 정화에 미치는 영향)

  • Deuk-Kyun Oh;Jeong-Ho Kim
    • Korean Journal of Environment and Ecology
    • /
    • v.38 no.2
    • /
    • pp.217-226
    • /
    • 2024
  • This study aimed to investigate the influence of anions in the air on the purification of fine dust (PM10 and PM2.5) and to evaluate the effects of plants on the generation of anions in the air and the purification of fine dust. Subsequently, the fine dust reduction models were compared according to each factor and plant volume. The characteristics of anion generation by each factor were observed to be in the order of Type N.I (negative ion generator; 204,133.33 ea/cm3) > Type P30 (plant vol. 30%; 362.55 ea/cm3) > Type C (control; 46.22 ea/cm3), indicating that the amount of anion generation in the anion generator treatment group and the plant arrangement group were approximately 4,417 times and 7 times higher, respectively, than that in the untreated group. Consequently, the fine dust reduction characteristics by anion generation source showed that for PM10, Type NI had a purification efficiency 2.52 times higher than Type C, and Type P30 was 1.46 times higher, while for PM2.5, Type NI had a purification efficiency 2.26 times higher than Type C, and Type P30 was 1.31 times higher. The efficiency of fine dust purification by plant volume was in the order of Type P20 (84.60 minutes) > Type P30 (106.50 minutes) = Type P25 (115.50 minutes) = Type P15 (117.60 minutes) > Type P5 (125.25 minutes) = Type P10 (129.75 minutes), and for ultrafine dust, Type P20 (104.00 minutes) > Type P30 (133.20 minutes) = Type P25 (144.00 minutes) = Type P15 (147.60 minutes) > Type P5 (161.25 minutes) = Type P10 (168.00 minutes). Thus, a quantitative analysis of the anions and plants for purifying fine dust and suggested matters to be considered for future green space planning and plant planting considering fine dust purification.

Study of the Performance of a Dry Cleaning Method for Polluted Ballast Gravel of Railroad Fields (철도부지 오염도상자갈의 건식 정화 기술 성능 연구)

  • Cho, Youngmin;Park, Duckshin;Kwon, Tae-Soon;Lee, Jae-Young
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.6
    • /
    • pp.552-557
    • /
    • 2015
  • Ballast gravel in a railroad field is often polluted by grease and heavy metals. In this paper, the performances of a dry cleaning method for polluted ballast gravel in which pollutants on the gravel surface can be physically removed was extensively studied. A polluted ballast cleaning device able to shoot emery blasting media onto the surface using compressed air was prepared. Polluted ballast gravel was put into this device for cleaning, with the treatment time varied from 1 to 10 min. The cleaning efficiency of the total petroleum hydrocarbons and heavy metals were studied. The total petroleum hydrocarbon removal efficiency was 70-80% for gravels sampled from a locomotive waiting line, while it was 40-60% for gravels sampled from a turnout area. The heavy metal removal efficiency exceeded 90% for copper and lead, while it was 65-80% for nickel and zinc. This system was found to be effective for the remediation of polluted ballast gravels.

Initial Analysis of the Underground Air Among Jeju Lava Forest(Sumgol) and its Healing Effect on the Human Body (제주 현무암 '숲' 지하 공기(숨골: Sumgol)의 분석과 인체에 미치는 치유 효과)

  • Sin, SBangsik;Kim, Hyek Nyeon;Lee, Deok Hee;Kim, Tae Seung;Kim, Yong Hwan;Kang, Chang Hee;Song, Kyu Jin;Lee, Hyung H.
    • Journal of Naturopathy
    • /
    • v.11 no.1
    • /
    • pp.18-30
    • /
    • 2022
  • Background: It was to develop an air purification system (APS) using an underground air purification layer to verify the effect of basalt forest's underground air (sumgol) on a volcanic Jeju. Finally, it is necessary to analyze these purified air components and their usefulness to the human body in an air experience center. Purpose: It was to collect basalt forest air, analyze its composition, and explore its effect on the human body. Methods: We APS devices installed at four points in the Papaville area of Jeju. The air discharged from the APS was collected and analyzed the recycling components. An installed experience room filled with negative ions is about 5,000 ions/m3. After allowing the participants to stay for 60 to 120 minutes, we investigated the state of blood vessels. Results: In the analysis of the underground air, the O2 concentration was 21.18%, which was higher than the average oxygen concentration of 20.94% in the atmosphere. However, Formaldehyde was not detected, and the CO2 was 419 ppm, which was lower than that of indoor air. The PM2.5 concentration was less than 24 ㎍/m3 and detected anions over 5.000 /m3. The experiencer's vascular states improved, and the increase in pulse rate and stress relief were high. Conclusions: The valuable ingredients identified by analyzing the air were precious for natural healing. The experience results showed that it effectively improved the pulse rate, blood vessels, and stress. These conditions may be highly beneficial as a new area for expanding the basalt lava forest in the Jeju area into the natural healing and wellness industry.

Production of air purification verification system using moss (이끼를 활용한 공기정화 검증 시스템 제작)

  • Ahn, Dohyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.6
    • /
    • pp.587-591
    • /
    • 2019
  • Fine dust aerated in the atomsphere penetrates our lungs and blood lines through respiratory. Recent fine dust problems in Korea leads to development of various air purifiers. The researchers used this to study systems that could replace chemical filters. In order to compare the effect of the reduction of moss and conventional chemical filter(Hepa), a 1 cubic meter cube was prepared and the amount of the concentration of fine dust reduction was compared under controlled environment. Under the high concentration of fine dust, a test was done to figure out the reduction rate of the fine dust concentration by using air purification system with moss, hepa, and no filter. The air purification system(moss, hepa, and no filter) were operated 90 times in total, 30 times each. The test explains that the reduction of the fine dust amount and the rate of fine dust concentration. The results illustrate that the reduction of the amount fine dust was 138.93 after using air purification system with moss filter. In contrast, the usage of air purification system with hepa filter reduced the amount of fine dust to 76.57. And the air purification with no filter shows that the slight reduction of fine dust amount at 0.10. In the rate of fine dust concentration, moss filter was significantly higher than that of hepa, no filter (0.2379, 0.1298 and 0.0063 each). The results have confirmed that moss is effective in reducing fine dust concentration, and it is expected that with further improvement it can be used as a means to replace or supplement existing chemical filters in air purifier.