• Title/Summary/Keyword: 공기 분배기

Search Result 24, Processing Time 0.037 seconds

Development of a Ultra Broadband Optical Coupler Based on a Photonic Crsytal Fiber (광자결정 광섬유기반 광신호 분배기 개발)

  • Yoon, Min-Seok;Lee, Sang-Bae;Han, Young-Geun
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.5
    • /
    • pp.195-199
    • /
    • 2010
  • A broadband optical coupler with a broad bandwidth of 1000 nm based on a photonic crystal fiber (PCF) is investigated. The PCF has 6 layers of air hole structures and a diameter of $130{\mu}m$. The PCF-based coupler is fabricated by using a fused biconical tapering method based on heating and elongation processes. Changing temperature and an elongation length can control the bandwidth and the bandedge wavelength of the PCF-based broadband coupler. The diameter of the fused region in the PCF-based coupler was measured to be $23{\mu}m$. The fabricated PCF-based coupler has a nearly-flat coupling ration of 3-dB in a broad bandwidth of 1000 nm, which is wider than that of the previously reported PCF-based coupler and that of the single-modefiber-based coupler. Since the resolution of optical coherence tomography system is proportional to the bandwidths of both an optical light sources and an interferometer, the fabricated PCF-based broadband optical coupler has a great potential for realization of a broadband interferogram.

A Method for Improving Air Distribution Performance at the Residence Ventilation System (주거 환기 시스템의 공기 분배 성능 개선 방안)

  • Park, Eun-Jun;Kim, Yong-Bong;Na, Hee-Hyoung;Lee, Sang-Ki
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.589-593
    • /
    • 2007
  • In the mechanical ventilation system, it is a fundamental condition to distribute the air equally to the each room. In this study, distribution performance of the air distributor which generally connected to a circular duct was investigated by simulation and experiment. In the first CFD analysis, maximum air flow rate deviation was an 63% in the air distributor model. After numbers of model modification and simulation, maximum flow rate deviation was reduced to 19% in the final simulation model. An air distributor which used in the experiment was produced by using data obtained from the final analysis. When experimental result was compared with analysis result, there was a deviation difference as much as 9%.

  • PDF

A Study on the Liquid-level Sensors Using Splitting Ratio of Fiber-optic Directional Couplers (광섬유형 방향성 결합기의 광 분배비를 이용한 수위 센서 연구)

  • Sohn, Kyung-Rak;Key, Kwang-Hyun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.34 no.6
    • /
    • pp.846-851
    • /
    • 2010
  • A liquid-air interface sensing system using the flat end surfaces of a fused-silica fiber coupler has been demonstrated. The principle is based on the additional optical loss caused by changing the refractive index of the external material at the boundary of the end face made of a fiber. The immersion characteristics of this system with respect to the different splitting ratios of the couplers were investigated to determine the sensitivity when it responses to water and air. These experimental data are very useful for selecting the coupling ratio of a coupler in order to develop a multiple sensing probe system. In the proposed sensor structure, it can be emphasize that the sensing probe can be appropriately arrayed on the basis of splitting ratio of the coupler. As a result, it is expected that the proposed liquid-air interface sensors can also be applied to monitor flooding that occurs in multiple areas at the same time.

Numerical Simulation of a Heat Pump Evaporator Considering the Pressure Drop in the Distributor and Capillary Tubes (분배기와 모세관을 고려한 히트펌프용 증발기 성능 모사)

  • Park, Young-Gi;Ye, Huee-Youl;Lee, Kwan-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.6
    • /
    • pp.476-486
    • /
    • 2012
  • A simulation program was developed to evaluate the heat transfer performance of a multi-pass fin-tube evaporator, considering the pressure drop in the distributor and capillary tubes. The effect of capillary tube length for each pass was analyzed with various inlet air flow types and distributions. The appropriate capillary tube length distribution and correlation were determined for various inlet air flow types and distributions. The correlated results agreed well with the simulation, with an average error of less than 7%. By applying an optimal capillary tube length distribution, the heat transfer rate was increased by 4~5% compared to cases with uniform tubelength distributions, for each of the inlet air flow types and distributions considered in this study.

Flow Distribution Analyses for the Energy and Environmental Plant (에너지환경 플랜트에서의 유량 분배 해석)

  • 김종현;이진욱;심성훈;김석준
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 2002.05a
    • /
    • pp.245-250
    • /
    • 2002
  • 보일러의 압입송풍기 토출구로부터 나온 연소용 공기를 버너가 있는 장소로 이동시키기 위해 설치하는 풍도(air duct)는 보다 원활한 연소용 공기의 공급과 효율적인 운송을 통하여 연소로에서 배출되는 연소 배출물인 SOx, NOx 등이 최소가 될 수 있도록 연소운전조건을 개선하여 연소로 내부에서의 화염을 안정화시킴으로 고효율 보일러의 운전환경을 제공할 수 있기 때문에 설계 단계에서 충분한 연구가 필요하다고 보여진다.(중략)

  • PDF

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택내 다분기챔버형 환기시스템 적용을 통한 풍량분배 개선효과에 관한 연구)

  • Kim, Sung-Soo;Son, Jang-Yeul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.10
    • /
    • pp.545-552
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. And TAB process is applied to control the designed air volume with adjusting volume dampers and/or supply diffusers after fully installing the ventilation system. This process has been resulted increasing the initial cost for the residential ventilation system because of man-hour and accessories such as volume control damper or diffuser. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system.

Simulation to identify the frost formation of the heat pump outdoor unit (히트펌프 실외기의 서리층 형성을 파악하기 위한 시뮬레이션)

  • Kim, Jong-Ryeol
    • Journal of the Korean Applied Science and Technology
    • /
    • v.36 no.4
    • /
    • pp.1410-1419
    • /
    • 2019
  • In this research, it is to find a method that frost does not form on the outdoor unit to develop a heat pump capable of heating in cold regions. For this reason, we produced an incubator capable of creating an environment of -25℃, and constructed an experimental apparatus so that experiments in the room were possible. However, it is necessary to grasp the characteristics of the air reaching the front of the heat pump outdoor unit installed in the experimental apparatus, and flow analysis was performed using ANSYS CFX, which is general-purpose software. As a result, the flow velocity of the air reaching the front of the outdoor unit in the outdoor unit chamber in the entire region of the simulation conditions (5.0 to 7.5 m/s) has many differences in the upper and lower portions, resulting in a natural state. It turned out that the condition can not be satisfied. Therefore, it is determined that it is necessary to additionally install a frequency divider at the front of the outdoor unit to make the flow velocity constant.

Performance Load Balancing and Sensitivity Analysis of Ramjet/Scramjet for Dual-Combustion/Dual-Mode Ramjet Engine Part I. Performance Load Balancing (이중램제트(이중연소/이중모드)엔진을 위한 램제트/스크램제트의 작동영역분배 및 성능민감도분석 Part I. 작동영역분배)

  • Kim, Sun-Kyoung;Jeon, Chang-Soo;Sung, Hong-Gye;Byen, Jong-Ryul;Yoon, Hyun-Gull
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.6
    • /
    • pp.586-595
    • /
    • 2010
  • An analytical study based on physical understandings and aero-thermodynamic theories was conducted to observe the performance characteristics and to derive the essential design parameters of dual ramjet(dual-combustion/dual-mode) propulsion for wide Mach number. The performances and operating limitations of the engines with two types combustors, such as constant pressure- and constant area- combustor, over various flight Mach numbers was investigated. Finally, the transition Mach number from ramjet to scramjet was carried out to optimize performance load balancing of ramjet and scramjet.

Experiments on the Characteristic of Storage Tank in In-Water Harvest-Type Ice Storage System (수중 하베스트형 빙축열시스템의 축열조 특성 실험)

  • 최인수;김재돌;윤정인
    • Journal of Energy Engineering
    • /
    • v.9 no.4
    • /
    • pp.366-371
    • /
    • 2000
  • 본 연구는 동적형 빙축열시스템에 있어서 증발판이 축열조 상부에 설치되어 생성된 얼음을 주기적으로 분리, 이탈시켜 하부에 설치된 축열조에 저장하는 기존의 하베스트형 빙축열시스템과는 반대로 축열조 내에 증발판을 설치하여 수중에서 얼음을 생성시키고 분리시켜 부럭에 의해 얼음을 띄워 저장하는 새로운 방식의 수중 하베스트형 빙축열시스템 개발에 관한 연구이다. 본 방식은 축열조 내에 증발판이 설치되어 제빙과 탈빙이 이루어짐으로서 기존 시스템에 설치되는 순환펌프나 순환수 분배기 및 배관 등의 설비가 불필요하고, 또한 조내 물과 증발판이 직접접촉에 의해 열교환이 이루어지므로 기존 공기 중에서의 열교환 방식보다 전열효율이 우수한 장점을 가지고 있다. 따라서 본 연구에서는 상기의 수중 빙제조 방식에있어 빙 제조시와 방냉시 축열조의 열특성을 실험적으로 밝혀 시스템 최적화 및 성능 향상에 대한 기초 자료를 제공하고자 하였다.

  • PDF