• Title/Summary/Keyword: 공기 균일성

Search Result 117, Processing Time 0.035 seconds

Characteristics of Ferralsols Soils and Rice Growth in Buchanan Region, Liberia (LIBERIA BUCHANAN 지역 FERRASOLS 토양의 이화학적 특성과 수도생육)

  • Jo, Guk Hyun;Kim, Kwang Sik;Kim, Yong Woong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.30 no.2
    • /
    • pp.168-177
    • /
    • 1997
  • This study was carried out to find the physico-chemical properties of soils and the rice growth at the pilot project rice farm of Buchanan city, Liberia. The results were as follows. Soils were classified as Plinthic Ferralsols. Real tropical soils had an oxic B horizon of 30cm thick with diffused horizon boundaries. The surface soils have Ochric A horizon with low organic matter. Plinthite was distributed throughout the whole soil profile unevenly. Exposed to sun light, Plinthite was dried out, hardened, and developed irreversibly into ironstone. There were 286 termite hills in 20ha in the project area. The pH value of the termite hills was higher than that of the ordinary soil two units. Soils of the termite hills had higher contents of carbon, nitrogen, available phosphate and exchangeable bases, especially calcium(2,000mg/kg). Available Fe contents was 230~330mg/kg in the surface soil, and 2,200mg/kg in the subsoil. This caused bronzing of rice in a few days after transplanting. The tolerance of Fe toxicity was lower in Korean cultivars than in Liberian cultivars. The tolerant cultivar was Hangang among Korean cultivars and Nizersail and Suakoko 8 among Liberian cultivars. Area weighted average percolation rate was 8.3mm/day and infiltration rate was 2~2.5mm/hr.

  • PDF

Preparation and Electrical Properties of Conductive Polyaniline Langmuir-Blodgett Thin Films Doped by Various Dopants (여러가지 도판트에 의해 도핑된 전도성 폴리아닐린 LB 박막의 제조 및 전기적 성질)

  • Oh, Se Young;Oh, Byung Keun;Choi, Jeong Woo;Kim, Hyung Su;Rhee, Hee-Woo;Lee, Won Hong
    • Applied Chemistry for Engineering
    • /
    • v.8 no.2
    • /
    • pp.172-178
    • /
    • 1997
  • Polyaniline(PANI)-stearic acid(SA) composite monolayer was formed at the air-water interface. The stearic acid as a surfactant was used to promote PANI monolayer formation. Uniform PANI-SA monolayer assemblies with Y type and transfer ratio of ca. 1 were fabricated using the Langmuir-Blodgett(LB) technique. The PANI-SA composite LB films with high electrical conductivity of $10^{-1}{\sim}10^{-2}S/cm$ were obtained by doping of HCl or $I_2$, and their conductivity revealed essentially close value as that of conventional PAHI-HCl complex. Especially, iodine is found to be the most promising dopant, since it gives a remarkable stability for the application as a polymer electrode in the MIM molecular device consisted of acceptor, sensitizer, and donor. The structure and physical properties of PANI-SA LB films were investigated through the near-ir UV, FT-IR, and Cyclic voltammetry.

  • PDF

Improvement on the KFOOD Code for More Realistic Assessment of the Annual Food Chain Radiation Dose Due to Operating Nuclear Facilities (가동중 원자력 시설에 의한 년간 섭식경로 피폭선량 평가의 현실성 제고를 위한 KFOOD 코드의 개선)

  • Park, Yong-Ho;Lee, Chang-Woo;Kim, Jin-Kyu;Lee, Myung-Ho;Lee, Jeong-Ho
    • Nuclear Engineering and Technology
    • /
    • v.25 no.3
    • /
    • pp.437-446
    • /
    • 1993
  • More realistic calculation models for evaluating man's annual intakes of radionuclides released from operating nuclear facilities were established. For the application of these models, the harvest years of food and feed crops consumed in the year of dose assessment and every year's average concentrations of a radionuclide in air and in water for the whole period of real operation had to be taken into account. KFOOD, an existing equilibrium food chain computer code for the Korean dose assessment, was modified according to the models. Sample runs of the modified code on the assumption of a constant release during 10 years' operation were made with three kinds of the input data files enabling the dose assessment in the improved method, the KFOOD method and another existing method, respectively, and the results were compared. Annual committed effective doses to Korean adult by intakes of Mn-54, Co-60, Sr-90, I-131 and Cs-137 calculated in the improved method were about 11, 2, 5, 60 and 3%, respectively, lower than the corresponding KFOOD dose. To the intakes of the radionuclides except Sr-90 evaluated in the improved method, foliar uptake contributed much more than root uptake did but, in the case of Sr-90, the result was opposite.

  • PDF

Characterization of Layered Double Hydroxides(Mg-Al-$CO_3$ systems) and Rehydration Reaction of Their Calcined Products in Aqueous Chromate Solution (층상이중수산화물(Mg-Al-$CO_3$ 체계)의 물리 · 화학적 특성규명 및 소성된 시료의 크롬산이온 수용액에서 재수화반응)

  • Rhee, Seog Woo;Kang, Mun-Ja;Moon, Hichung
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.8
    • /
    • pp.627-634
    • /
    • 1995
  • Layered double hydroxides ($Mg-Al-CO_3$ systems, LDH), which are hydrotalcite-like anionic clay minerals, having different $Mg^{2+}\;to\;Al^{3+}$ ratio were synthesized by coprecipitation method. The subsequent products were characterized by the following methods; elemental analysis, X-ray powder diffraction, thermal analysis (DSC and TGA), FT-IR and $^{27}$Al-MAS NMR. X-ray powder patterns showed that the products formed were layered structure materials. Two heat absorption peaks were observed around 20 ∼280$^{\circ}C$ (surface water and interlayer water) and 280∼500$^{\circ}C$ (water from lattice hydroxide and carbon dioxide from interlayer carbonate) in DSC diagrams, and they were quantitatively analyzed by TGA diagrams (in case LDH4 16.2% and 28.6% respectively). FT-IR spectra indicate that the interlayer carbonate ions occupied symmetrical sites between two adjacent layers in a parallel direction. $^{27}$Al-MAS NMR spectra show only single resonance (8.6 ppm) of the octahedrally coordinated aluminum similar magnesium. When LDH4 was calcined at 560$^{\circ}C$ for 3 hours in air, its layered structure was destroyed giving a mixed metal oxide. However it readily became rehydrated in aqueous chromate solution to its original structure.

  • PDF

Real-time Observation of Evolution Dynamics of Ge Nanostructures on Si Surfaces by Photoelectron Emission Microscopy (자외선 광여기 전자현미경을 이용한 Si 표면 위에 Ge 나노구조의 성장 동역학에 관한 실시간 연구)

  • Cho, W.S.;Yang, W.C.;Himmerlich, M.;Nemanich, R.J.
    • Journal of the Korean Vacuum Society
    • /
    • v.16 no.2
    • /
    • pp.145-152
    • /
    • 2007
  • The evolution dynamics of nanoscale Ge islands on both Si (001) and (113) surfaces is explored using ultraviolet photoelectron emission microscopy (UV-PEEM). Real-time monitoring of the in-situ growth of the Ge island structures can allow us to study the variation of the size, the shape and the density of the nanostructures. For Ge depositions greater than ${\sim}4$ monolayer (ML) with a growth rate of ${\sim}0.4\;ML/min$ at temperatures of $450-550^{\circ}C$, we observed island nucleation on both surfaces indicating the transition from strained layer to island structure. During continuous deposition the circular islands grew larger via ripening processes. AFM measurements showed that the islands grown on Si (001) were dome-shaped while the islands on Si (113) were multiple-side faceted with flat tops of (113)-orientation. In contrast, for Ge deposition with a lower growth rate of ${\sim}0.15\;ML/min$ on Si(113), we observed the shape transition from circular into elongated island structures. The elongated islands grew longer along the [$33\bar{2}$] during continuous Ge deposition. The shape evolution of the islands is discussed in terms of strain relaxation and kinetic effects.

The Effect of Storage Container Types on Odor Emission and Quality of Piggery Liquid Slurry Fertilizer in the farms (농가의 돈분액비 저장형태가 악취발생과 액비품질에 미치는 영향)

  • Park, Moo-Eon;Kang, An-Seok;Kim, Si-Chang
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.39 no.3
    • /
    • pp.136-143
    • /
    • 2006
  • The study was carried out to evaluate odor emission during storage time and quality of liquid slurry fertilizer along with three storage container types installed at farmer's fields in Cheorwon. Liquid slurry manure stored in the liquid-circulated or the air-injected tank was very homogeneous in concentration of nutritional elements because of well mixing operation, while nutritional concentration of the manure stored in the non-treated tank was significantly different from top to bottom in the tank, which may bring about partially irregular growth of plant after its application. The potential capacity of offensive odor emitted from liquid slurry manure stored in the liquid-circulated or the air-injected tank was much lower than that emitted from manure stored in the non-treated tank. Low potential capacity may less emit offensive odor after application of piggery liquid slurry on the field. The efficiency in oder to reduce odor emission from liquid manure was slightly higher in the liquid-circulated tank than the air-injected tank

Effects or air current speeds on the growth or eggplant plug seedlings in a wind tunnel under artificial lighting (인공광하의 풍동내에서 기류속도가 가지 플러그묘의 생장에 미치는 영향)

  • 김용현
    • Journal of Bio-Environment Control
    • /
    • v.7 no.1
    • /
    • pp.9-14
    • /
    • 1998
  • Air current speeds were controlled of 0.3, 0.5, 0.7 and 0.9 m.s$^{-1}$ to investigate the effects of air current speeds on the growth of eggplant plug seedlings (Solanum melongena L.) in a wind tunnel under artificial lighting. Growth of plug seedlings was influenced by the magnitude of air current speed and the traveling distance of regulated air flow. Stem length. ratio of length to diameter in stem, plant height .and number of leaves of plug seedlings decreased with the increasing air current speed and were significantly different at 5% level. Net photosynthetic rates of plug stand increased with the increasing air current speed and took a maximum value at the air current speed of 0.7~09 m.s$^{-1}$ . Stem diameter decreased and leaf area increased with the traveling distance of regulated air flow. Fresh weight and T/R ratio of dried weight were not influenced by the air current speed. Optimum control for microclimates inside the plug stand is needed to produce the uniform growth and high quality of plug seedlings in a semi-closed plant Production system under artificial lighting.

  • PDF

A Study on Cooling Condition for Quality Improvement of Rotary Molding Machine (회전성형기의 품질 향상을 위한 냉각 조건에 관한 연구)

  • Kang, Jeong-Seok;Kim, In;Lee, Myungjae;Yoon, Jai-young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.367-371
    • /
    • 2019
  • The molding for hollow products used widely in industry is rotational molding by heating and cooling. Uniform cooling is required to improve the quality of the product, and rapid cooling is required to improve the productivity. In this paper, the cooling condition is largely classified into the case of no forced cooling by the fan and forced cooling by the fan. In addition, when forced cooling by the fan is not performed, the condition for stopping the molding machine horizontally and the condition for stopping the molding machine vertically were classified. To confirm the forced cooling by the fan, the conditions were set such that only the molding machine rotates while the fan is not running and the upper and lower fans operate when only the lower fan is operated. The surface temperature of the rotary molding machine was analyzed by the STAR-CCM+ program for the case of air-cooling. The temperature distribution of the rotary molding machine was analyzed for five conditions and the temperature distribution for cooling was compared under each condition. Among the five cases, Case 4 was lowest at approximately 35 ℃ after 900sec.

Characteristics of Anode-supported Flat Tubular Solid Oxide Fuel Cell (연료극 지지체식 평관형 고체산화물 연료전지 특성 연구)

  • Kim Jong-Hee;Song Rak-Hyun
    • Journal of the Korean Electrochemical Society
    • /
    • v.7 no.2
    • /
    • pp.94-99
    • /
    • 2004
  • Anode-supported flat tubular solid oxide fuel cell (SOFC) was investigated to increase the cell power density. The anode-supported flat tube was fabricated by extrusion process. The porosity and pore size of Ni/YSZ ($8mol\%$ yttria-stabilized zirconia) cermet anode were $50.6\%\;and\;0.23{\mu}m$, respectively. The Ni particles in the anode were distributed uniformly and connected well to each other particles in the cermet anode. YSZ electrolyte layer and multilayered cathode composed of $LSM(La_{0.85}Sr_{0.15})_{0.9}MnO_3)/YSZ$ composite, LSM, and $LSCF(La_{0.6}Sr_{0.4}Co_{0.2}Fe_{0.7}O_3)$ were coated onto the anode substrate by slurry dip coating, subsequently. The anode-supported flat tubular cell showed a performance of $300mW/cm^2 (0.6V,\; 500 mA/cm^2)\;at\;500^{\circ}C$. The electrochemical characteristics of the flat tubular cell were examined by ac impedance method and the humidified fuel enhanced the cell performance. Areal specific resistance of the LSM-coated SUS430 by slurry dipping process as metallic interconnect was $148m{\Omega}cm^2\;at\;750^{\circ}C$ and then decreased to $148m{\Omega}cm^2$ after 450hr. On the other hand, the LSM-coated Fecralloy by slurry dipping process showed a high area specific resistance.

A Simplified Closed Static Chamber Method for Measuring Methane Flux in Paddy Soils (논토양(土壤)의 메탄 배출(排出) 측정(測定)을 위한 간역폐쇄정태(簡易閉鎖靜態) Chamber법(法))

  • Shin, Yong-Kwang;Lee, Yang-Soo;Yun, Seong-Ho;Park, Moo-Eon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.28 no.2
    • /
    • pp.183-190
    • /
    • 1995
  • Various factors such as sampling height in the chamber, sampling interval, sampling time at daytime and the effects of pedoturbation on methane emission during chamber installation were evaluated using a simplified closed static chamber method to measure methane flux in paddy soils. Sampling height of the chamber for representative samples was 65cm. An additional DC fan was required to attain an even methane gradient in the chamber. Considering the change of methane concentration and air temperature in the chamber, sampling is recommended to finish within 30 minutes after starting sampling. The aim of setting DC fan in the chamber was to get the thermal equilibrium in the chamber as well as the representative samples. Suitable time to collect the gas samples representing the day's methane flux was 0900~1200 hours. Gas sampling was possible even after installation of small chambers if the elapsed time was more than 6 hours and supporting stand would be to be added to minimize pedoturbation.

  • PDF