• Title/Summary/Keyword: 공기비

Search Result 2,578, Processing Time 0.025 seconds

Adjustment of the Excess Air Ratio for Stabilizing the Draft System in a Large Capacity Coal Fired Power Plant (대형 석탄화력 발전소에서 통풍계통 안정화를 위한 과잉공기비 조정)

  • Park, Kun Woo;Yoo, Ho-Seon
    • Plant Journal
    • /
    • v.14 no.2
    • /
    • pp.39-44
    • /
    • 2018
  • In this study, I analyzed the effects on stabilizing the draft system, boiler efficiency when changing excess air ratio under 870 MW load limit operation condition in a large capacity coal fired power plant and decided optimum excess air ratio. It is positively necessary to choose adequate excess air ratio for stabilizing draft system because air pre-heater pressure drop and induced draft fan first stall margin are changing when adjusting excess air ratio. This study therefore, measured air pre-heater pressure drop, induced draft fan first stall margin, boiler efficiency, loss and has chosen adequate excess air ratio adjusting excess air ratio from 1.153 to 1.127. So it is recommended that the operation point needs to be changed to 1.127 that is not only to decrease air pre-heater pressure drop and to stabilize draft system and to secure stall margin but also to maintain boiler efficiency to equivalent level.

  • PDF

CFD Modeling of Unsteady Gas-Liquid Flow in a Small Scale Air-Lift Pump (소형 공기 양수 펌프의 불규칙한 가스-액체 흐름의 CFD 모델링)

  • Li, X.S.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.16 no.1
    • /
    • pp.30-37
    • /
    • 2012
  • 공기 양수 펌프는 재생 에너지 분야, 부식 및 마모 특성의 유체의 활용 등 높은 신뢰성과 낮은 유지보수 비용을 필요로 하는 분야에서 그 사용이 증대되고 있다. 본 연구에서는 소형 공기 양수 펌프의 성능 평가 및 기초 데이터를 얻기 위한 연구로, D=0.012~0.019m, L=0.933m인 배관의 침수 깊이(${\beta}$=0.55,0.60,0.65,0.70)에 따른 수치해석을 수행하였다. 수치 해석 및 실험 결과는 유사성을 뛰었으며, 펌프의 사양과 효율은 공기의 질량 유속 비, 침수 깊이 비와 양수 배관의 길이에 관한 함수로 나타났다. 그리고 최대 물과 공기 질량 유속의 비는 각 배관에서 서로 다른 침수 깊이의 비로 나타났으며, 공기 양수 펌프의 최대 효율이 발생되는 운전조건은 슬러그(slug)와 슬러그 교반 정도(slug-churn flow regime)에 따라 나타남을 알 수 있었다.

Effect of Aerodynamic Nonlinearity on Drive-Train of Wind Turbine (공기역학적 비선형성이 풍력발전기 드라이버-트레인에 미치는 영향)

  • Lim, Chae-Wook
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.235-235
    • /
    • 2010
  • 풍력발전기의 공기역학적 비선형성은 풍력발전기 전체 시스템의 동적특성에 영향을 미친다. 풍력발전기의 드라이버-트레인의 감쇠가 매우 작으므로 풍력발전기를 제어함에 있어 드라이버-트레인의 동적특성은 중요하게 고려되어야 한다. 본 논문에서는 풍속에 따른 공기역학적 비선형성이 드라이버-트레인의 동적특성에 미치는 영향을 해석적으로 살펴보고자 한다.

  • PDF

Reliability Estimation of Site Investigation by Geotechnical Risk Analysis in Subway Tunnel (지하철 터널에서의 위험도 분석을 통한 지반조사 신뢰성 평가)

  • 김환준;김우성;김영근;이두화;박진우;김갑부
    • Proceedings of the Korean Society for Rock Mechanics Conference
    • /
    • 2004.10a
    • /
    • pp.13-22
    • /
    • 2004
  • 본 연구에서는 도심지 지하철 터널을 대상으로 지반공학적 위험요소가 공사비 및 공기에 미치는 영향을 정량적으로 평가하기 위하여 잔여 리스크 개념을 이용하여 조사개소의 증가에 따른 공사비 및 공기의 신뢰도를 분석하였다. 신뢰도 분석결과, 지반조사 개소가 증가함에 따라 공사비 및 공기에 대한 위험도가 축소됨을 확인하였으며, 이러한 결과를 통하여 도심지 지하철 터널에서의 지반공학적 위험도 분석의 유용성을 확인하였다.

  • PDF

자유류와의 분사 압력비와 분출구 형상에 따른 공기 우산 효과 연구

  • Hwang, Jae-Min
    • Proceeding of EDISON Challenge
    • /
    • 2016.11a
    • /
    • pp.71-73
    • /
    • 2016
  • 기존 우산의 단점을 보완한 발명품, 공기우산이 개발되었다. 하지만 공기우산의 단점인 짧은 사용시간을 보완하기 위해 강우량에 따라 적절하게 공기 분사압을 변화시키는 것뿐만 아니라 공기우산의 사용인원의 조절을 위해 압력비와 분사구 형태에 따른 우산의 효과를 알아보는 것이 실 사용에 중요한 요소일 것이다. 이에따라 본 연구에서는 우산 앞 부분의 분출구 형상과 자유류와의 분사 압력비에 따른 자유류의 방어 능력을 확인해 보았다. 평면 분사구에서 압력비가 1.3, 1.5인 구간에서는 우산의 효과를 나타낼 수 없었고 압력비가 1.5인 구간부터 삼각형 분사구와 육각형 분사구에서 우산의 형태가 나타남을 알 수 있었다. 압력비가 2.0인 구간에서 육각형 분사구의 경우 통상적인 우산의 형상을 보이기 시작하는 것을 알 수 있다.

  • PDF

공기순환비에 따른 음식물쓰레기의 감량화 특성

  • Jang, Seong-Ho;Seo, Jong-Hwan;Park, Jin-Sik;Mun, Chu-Yeon
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2006.05a
    • /
    • pp.347-350
    • /
    • 2006
  • 본 연구에서는 음식물쓰레기를 배출공기순환방식을 적용한 고온호기성 공정에서 공기순환비에 따른 음식물쓰레기의 감량화 특성을 연구하였다. 그 결과 적정한 평균운전온도는 54$^{\circ}C$, 함수율은 40% 정도로 판단되었다. 공기순환비 0.5에서 최대기질제거량을 나타내었지만 본 실험이 15일간으로 짧게 운전된 점과 반응후반부에서 공기순환비이 0.3, 0.5일 경우 반응 온도가 하락되어 기질 제거량에 영향이 예상됨으로 15일 이상 기간으로 운전시 적정한 공기순환비는 0.7로 판단된다.

  • PDF

Development of an Effective Time Scheduling Mechanism of the Structural Framework for the High-rise Apartment Housing -Focusing on One Cycle Time Scheduling Mechanism of Typical Floor- (아파트 골조공사의 공기단축 및 효과적 공정운영 방안 -기준층 사이클 공정분석을 중심으로-)

  • Han Choong-Hee;Bang Jong-Dae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.5 no.4 s.20
    • /
    • pp.87-96
    • /
    • 2004
  • The construction duration in apartment construction is an important factor which affects project cost. Henceforth, the time shortening is essential to retrench project cost and project risk when there adopt Five-Day Workweek and introduce apartment sales after completion of construction. Therefore, the purpose of this study is to examine closely the affecting factors on the duration of framework which forms about $40\sim50\$ percent of total time in apartment construction by analyzing the schedule mechanism of typical floor and to show the reasonable time shortening methods by case study. The shown schedule mechanism and basic schedule table can utilize as a guideline in case of scheduling of framework in the existing construction method. Also, the shown time shortening methods by three case studies will guide the direction and process of time shortening while there need time shortening in many-sided projects.

Lab-Scale Air/Bio-Sparging Study to Remediate Diesel-Contaminated Soil and Groundwater : The Effect of Air Injection Rate and Pattern (디젤오염 토양 및 지하수 복원을 위한 공기주입정화법 실험실 연구 : 공기주입량과 공기주입방식의 영향)

  • Chang, Soon-Woong;Lee, Si-Jin;Cho, Su-Hyung;Yoon, Jun-Ki
    • Journal of Soil and Groundwater Environment
    • /
    • v.11 no.4
    • /
    • pp.10-17
    • /
    • 2006
  • Laboratory-scale two-dimensional aquifer physical model studies were conducted to assess the effect of air injection rate and air injection pattern on the removal of disel contaminated soil and groundwater by air/bio-sparging. The experimental results were represented that the optimal conditions in this experiment were as air injection rate of 1,000 ml/min and pulsed air injection pattern(15 min on/off). The results of the TPH reduction, DO consumption and $CO_2$ production indicate the effective biodegradation evidence of diesel. Based on our results, The minimal $O_2$ supply and pulsed air injection pattern could effectively enhance the diesel removal and the pulsing air injection had effect on oxygenation in this system. Thus, the cost of operating air/bio-sparging system will be reduced if optimal air injection rate and pulsed air injection pattern are applied to remediate contaminants.

The Effect of Supply Patterns of Overfire Air on Generation of NOX and CO in a Wood pellet Fired Boiler (우드펠릿 보일러에서 2단 연소용 공기 공급방식이 질소산화물 및 일산화탄소 발생에 미치는 영향)

  • Jung, Kwang-sung;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.3
    • /
    • pp.35-41
    • /
    • 2019
  • In this study, we investigated the effect of the generation of NOx and CO by adjusting the overfire air supply position and ratio using the boiler that was converted from coal burning to wood pellet boiler. When the amount of the overfire air is relatively increased, the amount of NOx is slightly decreased but CO is sharply decreased when burning at low excess air ratio (1.10) that is due to a small fuel particle size. However, NOx slightly increased when burning at high excess air ratio (1.33) due to the large fuel size, but CO was hardly affected. Also, When the amount of overfire air was same, The more supply position was concentrated to upper portion of the main combustor, the more NOx and CO was lowered. And in case of the excess air ratio was high, the generation of NOx and CO I can see that it keeps the level irrelevant to the amount of air for the second stage combustion.

The Study on Aerodynamic Characteristics for the Design of High Efficiency Jet Vane (고 효율 제트 베인 설계를 위한 공기역학적 특성 연구)

  • 길경섭;정용갑;박종호
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.7 no.4
    • /
    • pp.39-45
    • /
    • 2003
  • Of the various means for active trajectory correction, a thrust vector control system represents the only principle independent of missile external forces so that this method is operative. The purpose of this study is to analyze the characteristic of jet vane TVC(Thrust vector control) system among mechanical jet deflection. To ensure high performance leading edge shape, aspect ratio and ablated condition is optimized. Supersonic flow system, jet vanes and nozzle with Mach number 2.88 and under expansion ratio 2 were designed to study aerodynamic characteristics of leading edge shape, aspect ratio and ablated conditions.