• Title/Summary/Keyword: 공기량 조정

Search Result 37, Processing Time 0.043 seconds

The properties of algal degradation and gas emission by thermophilic oxic process (고온호기발효장치를 이용한 조류 분해 및 가스 발생특성)

  • Kang, Changmin
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.7 no.2
    • /
    • pp.57-64
    • /
    • 1999
  • The purpose of this study is to establish effective conditions for controlling $CH_4$, $N_2O$ emission from organic Waste / wastewater treatment processes. Continuous and batch experiments were conducted to treat the micro algae from polluted and eutrophicated lakes through the thermophilic oxic process. The microalgae used were mainly Microcystis sp.(collected from eutrophic lake) and Chlorella sp. (cultured in laboratory) Wasted cooking oil was added by aid-heating source. Physico-chemical components of sludges and microalgae were analyzed. In batch experiments, air supply was changed from 50ml/min to 150ml/min. The temperature. water content and drained water were affected by the air flow rate at initial stage. However, there was almost no influence of air flow rate on them in middle and last stages. At air flow rate of 100ml/min, the degradation rate of organic material was higher than that at other air flow rates. $CO_2$ concentration in exhaust was proportional to the strength of aeration, especially at initial stage when degradation was active. $CH_4$ with low concentration was detected only at starting stage when air diffusion was not enough. $N_2O$ production was not affected by variation of air supply. In continuous experiments no matter what the dewatering methods (with PAC and without PAC) and media (wood chip and reed chip) were changed, $N_2O$ was almost not affected by variation of injected air. Result showed that the reed chips using for lake purification could be used as media for thermophilic oxic process in lake and marshes area. $CO_2$ concentration was not so much affected by the change of dewatering methods and media types. $CH_4$ was not detected in the experimental period. So it can be shown that the thermophilic oxic process had been well operated in wide handling conditions regardless of media and dewatering methods.

  • PDF

The Effect of Supply Patterns of Overfire Air on Generation of NOX and CO in a Wood pellet Fired Boiler (우드펠릿 보일러에서 2단 연소용 공기 공급방식이 질소산화물 및 일산화탄소 발생에 미치는 영향)

  • Jung, Kwang-sung;Yoo, Hoseon
    • Plant Journal
    • /
    • v.15 no.3
    • /
    • pp.35-41
    • /
    • 2019
  • In this study, we investigated the effect of the generation of NOx and CO by adjusting the overfire air supply position and ratio using the boiler that was converted from coal burning to wood pellet boiler. When the amount of the overfire air is relatively increased, the amount of NOx is slightly decreased but CO is sharply decreased when burning at low excess air ratio (1.10) that is due to a small fuel particle size. However, NOx slightly increased when burning at high excess air ratio (1.33) due to the large fuel size, but CO was hardly affected. Also, When the amount of overfire air was same, The more supply position was concentrated to upper portion of the main combustor, the more NOx and CO was lowered. And in case of the excess air ratio was high, the generation of NOx and CO I can see that it keeps the level irrelevant to the amount of air for the second stage combustion.

Combustion Characteristics of Coal-Fired Boiler Depending on the Variations in Combustion Air Supply Method (미분탄 보일러의 연소용 공기공급 변화에 따른 노내 연소상태 해석)

  • Seo, San-Il;Park, Ho-Young;Kang, Dong-Soo;Jeong, Dong-Hae
    • Journal of Energy Engineering
    • /
    • v.19 no.3
    • /
    • pp.156-162
    • /
    • 2010
  • 3-D CFD(Computational Fluid Dynamics) work were carried out to investigate the combustion characteristics in a boiler depending on the variations in air supply condition. For the gas temperature, $O_2$, NO, SOx at the outlet of economizer, the predicted values were been compared with the measured data. With the verified CFD model, the effects of air flow rates through SOFA(Separated Over Fire Air) and CCOFA(Closed Coupled Over Fire Air) on the combustion behavior in a boiler were simulated, and the distributions of NOx and gas temperature were mainly compared each other. The change in SOFA air flow rate gave the more sensitive effect on NOx than that in CCOFA. The distributions of gas temperature at convection path are differed with the changes in SOFA and CCOFA flow rate, so the combustion modification such as yaw anlge adjustment are required to get an enhanced gas temperature distribution.

Characteristic of Cementitious Mortar Using High Volume of Recycled Fine Aggregate (순환잔골재의 다량 사용에 따른 모르타르의 특성)

  • Kim, Sang-Chel;Park, Do-Kuk;Yoog, Keun-Chang
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.4 no.3
    • /
    • pp.235-242
    • /
    • 2016
  • As for a possibility of using high volume of recycled aggregate in concrete mixture, recycled fine one which is known to be worse in quality and hard to control was selected and investigated in terms of performance of mortar as the replacement ratio to natural fine aggregate was changed. As a result of test, it is found that grade of recycled fine aggregate was beyond standard one and fineness modulus of that itself was increased in compare to natural one. In case of making mortar with recycled fine aggregate, disadvantageous results such as less fluidity and air content including the increase of dry shrinkage were shown but strengths of mortar were comparable to the one making with natural aggregate, which means that planned strength of common concrete structure can be achieved by controlling W/C and the amount of chemical admixture, and also that large amount of recycled fine aggregate is applicable to the precast concrete products generally free to the amount of water.

유도 결합 플라즈마원의 외부 냉각에 관한 수치 모델링

  • Ju, Jeong-Hun;Jo, Jeong-Hui;Park, Sang-Jong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.218-218
    • /
    • 2016
  • 실린더 형태의 유전체 관에 나선형으로 도전체 안테나를 설치하는 타입의 유도 결합 플라즈마원은 간단한 구조로 화학 조성 분석용부터 나노 분말 제조, 반도체용 식각/증착, 표면 처리, 자동차 및 일반 산업 부품용 증착 보조원등으로 널리 사용되고 있다. 고밀도 라디칼/이온의 공급을 위해서 투입 전력을 증가시키는 경우 높은 전력 밀도로 인해서 유전체 관에 인가되는 열응력이 대기압 및 관 고정용 구조물에 의한 구조 응력에 더해져서 파손에 이르는 경우가 발생될 수 있다. 실제 실린더 길이 전체를 안테나 코일로 감는 경우에도 플라즈마 발생 밀도가 높은 지역은 중심 일부 영역에 국한 되는 공정 영역도 있어서 이에 대한 분석이 필요하다. CFD-ACE+를 이용하여 플라즈마의 생성, 냉각수의 열전도, 외부 공냉식 팬의 역할등에 대해서 수치 모델을 작성하여 검토하였다. 나선형 냉각코일의 경우 냉각수량을 일정값 이상으로 증가시키는 경우 유속이 지나치게 빨라져서 열원이 있는 내경쪽 표면에서 열전도가 유속에 비례해서 증가하지 못하는 단점이 발생할 수 있으며 냉각팬의 경우 일반적으로 장치 내부에 대해서만 모델링을 하는 데 실제로 전체 시스템의 주변에서 공기의 흐름을 넓게 해석해야 실제 냉각 효과를 파악할 수 있다. 심한 경우 냉각용 공기 흡입구와 토출구의 간격이 좁아서 열원에 의해서 가열된 공기의 상당량이 다시 냉각용 공기 흡입구로 재순환 되는 경우도 발생하기 쉽다.

  • PDF

Allowable Amount of Bed Inventory in a 300 MW Class Circulating Fluidized Bed Boiler (300 MW 급 유동층보일러에서 적정 층 물질량 산정)

  • Kim, Woo-Yong;Yoo, Ho-seon
    • Plant Journal
    • /
    • v.14 no.2
    • /
    • pp.33-38
    • /
    • 2018
  • The CFB boilers technology is facing a number of challenges. Among them, boiler tube erosion, sintering by bed inventory overheating and high self consumed service power are major ones. This study was conducted to obtain allowable bed inventory with the Yeosu Power Plant, a 300 MW class CFB boiler. For the test, bed pressure was reduced from design pressure of 4.5 KPa to 2.5 KPa by reducing bed inventory, at fixed turbine output, coal consumption rate and air flow. Consequently, reducing the lower bed inventory is effective to decrease bed temperature but excessive reducing might increase bed temperature due to lack of circulating fluidized materials. Also, in case of the Yeosu Plant boiler using subbituminous coal as its primary fuel, its bed temperature change is highly affected by not only the amount of bed inventory, but also the boiler capacity and coal contents.

  • PDF

Experimental and Theoretical Study on Silica Gel Regeneration (실리카 젤의 재생에 관한 실험적 및 이론적 연구)

  • 고학균;정도섭
    • Journal of Biosystems Engineering
    • /
    • v.2 no.2
    • /
    • pp.1-14
    • /
    • 1977
  • 현재 선진국에서 널리 이용되고있는 곡물의 화력건조는 곡물의 품질을 손상시킬 뿐만 아니라 손실을 증가시키고 있다. 화력에 의한 건조는 또한 연료의 절약면에서 볼 때 역시 문제점을 내포하고있다.l 이러한 문제점들을 해결하기 위하여 근래에는 실리카 젤과 같은 흡습성의 건조제를 사용한 곡물의 건조 실험이 진행 중에 있으며 좋은 결과를 보여주고 있다. 실리카겔은 그 자체무게의 40% 까지 동적 및 정적하에서 수분을 흡수하는 성질을 가지고 있으며 일단 포화상태가 되면 수천번 재생이 가능하다. 본 연구에서는 이와같은 실리카텍의 재생실험을 일차적으로 실내에서 공기의 온도를 일정하게 한 상태에서 실시하였으며 일반적으로 실리카 젤은 $300^{\circ}F$에서 완전재생이 가능하나 본 실험에서 사용된 재생온도는 평면식 태양열 집열기로부터 얻을 수 있는 $150^{\circ}F$ 내외에서 시도하였다. 본실험과 병행하여 건조중 공기와 실리카 젤의 에너지 및 질량변화에 따른 이론식을 만들어 주어진 여러 가지 조건에 대하여 4개의 미분방정식을 컴퓨터에 의하여 해결하였으며 건조(재생) 시간에 따른 공기의 온도와 흡습 및 실리카 젤의 함수량을 구하였다. 위의 이론적인 분석결과는 후에 태양열집열기를 이용한 재생실험을 분석하는데 적용될 것이다. 본 연구결과를 요약하면 다음과 같다. 1. 본 연구에서 유도한 이론식은 실리카 젤의 재생온도를 만족스럽게 표시하였으며 재생시간에 따른 공기의 온도와 흡습 및 실리카 젤의 함수량변화의 이론치는 실험치와 근사하였다. 2. 이론치와 실험치를 일치시키기위하여 흡착온도에서 산출된 열 및 질량 전달계수를 1/5로 조정 사용하였다. 3. 실리카 젤은 $120^{\circ}F$에서 9 %, $180^{\circ}F$에서 1% 내외로 재생이 가능하였다. 4. 본 연구에서 유도된 이론적 분석방법은 다른 여러 가지 형태의 물질 및 건조 또는 냉각 과정을 분석하는데 사용될 수 있다.

  • PDF

A Study on Field Application of 150MPa Ultra Strength Surface-Exposed Concrete (150MPa급 초고강도 노출콘크리트의 현장적용에 관한 연구)

  • Kong, Tae-Woong;Lee, Soo-Hyung;Jang, Jae-Hwan;Lee, Han-Baek
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.989-992
    • /
    • 2008
  • In this paper, we are presenting a case that integrates ultra high strength concrete(150MPa) with surface-exposed concrete. Ahead of the field application, we carried out laboratory experiment and B/P Test for a basic property of concrete(slump flow, air content, 50cm flow time, elapse time change and compression strength) and productivity. The next, we conducted Mock-up Test using simulation specimen to evaluate infilling, surface-finishing and hydration heat of concrete. We had satisfactory results for a basic property and hydration heat of concrete. However at the time of field application, it was occurred rupture of formwork because of high lateral pressure of concrete, and then formwork was reinforced and case-in-place time was adjusted. And regardless of low and high frequency vibration, it occurred to surface-pockmark. In case that applies ultra high strength concrete to surface-exposed concrete, we estimate that it is important of systematic management and improvement of construction.

  • PDF