• Title/Summary/Keyword: 공기동력학적 방법

Search Result 5, Processing Time 0.027 seconds

Applicability evaluation of aerodynamic approaches for evaporation estimation using pan evaporation data (증발접시 증발량자료를 이용한 공기동력학적 증발량 산정 방법의 적용성 평가)

  • Rim, Chang-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.11
    • /
    • pp.781-793
    • /
    • 2017
  • In this study, applicabilities of aerodynamic approaches for the estimation of pan evaporation were evaluated on 56 study stations in South Korea. To accomplish this study purpose, previous researchers' evaporation estimation equations based on aerodynamic approaches were grouped into seven generalized evaporation models. Furthermore, four multiple linear regression (MLR) models were developed and tested. The independent variables of MLR models are meteorological variables such as wind speed, vapor pressure deficit, air temperature, and atmospheric pressure. These meteorological variables are required for the application of aerodynamic approaches. In order to consider the effect of autocorrelation, MLR models were developed after differencing variables. The applicability of MLR models with differenced variables was compared with that of MLR models with undifferenced variables and the comparison results showed no significant difference between the two methods. The study results have indicated that there is strong correlation between estimated pan evaporation (using aerodynamic models and MLR models) and measured pan evaporation. However, pan evaporation are overestimated during August, September, October, November, and December. Most of meteorological variables that are used for MLR models show statistical significance in the estimation of pan evaporation. Vapor pressure deficit was turned out to be the most significant meteorological variable. The second most significant variable was air temperature; wind speed was the third most significant variable, followed by atmospheric pressure.

Size Verification of Small and Large Bubbles in a Bubble Column (기포탑에서 작은기포와 큰기포의 크기 구별)

  • Seo, Myung Jae;Jin, Hae-Ryong;Lim, Dae Ho;Lim, Ho;Kang, Yong;Jun, Ki-Won
    • Korean Chemical Engineering Research
    • /
    • v.50 no.2
    • /
    • pp.304-309
    • /
    • 2012
  • Size verification of small and large bubbles in a bubble column was investigated by employing the dynamic gas disengagement (DGD) method and dual electrical resistivity probe (DRP) method, simultancously. The holdups of large and small bubbles in the bubble column in a given operating condition were obtained by means of the DGD method by measuring the pressure drop variation in the column with a variation of time after stopping the gas input into the column. The size and frequency of bubbles were measured by the DRP method in the same operating condition, from which the bubble holdup of each range of size was obtained. The verification of size in determining the large or small bubbles was decided by comparing the holdups of large or small bubbles measured by the DGD method with that measured by the DRP method. Filtered compressed air and tap water were used as a gas and a continuous liquid medium. The diameter and height of the bubble column were 0.102 m and 1.5 m, respectively. The demarcation size between the large and the small bubbles in the bubble column was 4.0~5.0 mm; the demarcation size was about 5.0 mm when the gas velocity was in the relatively low range, but about 4.0 mm when the gas velocity was in the relatively high range, within this experimental conditions.

Study on the Suitability of Composite Materials for Enhancement of Automotive Fuel Economy (자동차 연비향상을 위한 복합재료 적용 타당성에 관한 연구)

  • Ju, Yeon Jin;Kwon, Young-Chul;Choi, Heung Soap
    • Composites Research
    • /
    • v.32 no.5
    • /
    • pp.284-289
    • /
    • 2019
  • In the present paper, the dynamic force-moment equilibrium equations, driving power and energy equations are analyzed to formulate the equation for fuel economy(km/liter) equivalent to the driving distance (km) divided by the fuel volume (liter) of the vehicle, a selected model of gasoline powered KIA K3 (1.6v). In addition, the effects of the dynamic parameters such as speed of vehicle (V), vehicle total weight(M), rolling resistance ($C_r$) between tires and road surface, inclined angle of road (${\theta}$), as well as the aerodynamic parameters such as drag coefficient ($C_d$) of vehicle, air density(${\rho}$), cross-sectional area (A) of vehicle, wind speed ($V_w$) have been analyzed. And the possibility of alternative materials such as lightweight metal alloys, fiber reinforced plastic composite materials to replace the conventional steel and casting iron materials and to reduce the weight of the vehicle has been investigated by Ashby's material index method. Through studies, the following results were obtained. The most influencing parameters on the fuel economy at high speed zone (100 km/h) were V, the aerodynamic parameters such as $C_d$, A, ${\rho}$, and $C_r$ and M. While at low speed zone (60 km/h), they are, in magnitude order, dynamic parameters such as V, M, $C_r$ and aerodynamic ones such as $C_d$, A, and ${\rho}$, respectively.

분무진공동결건조기 개발

  • Ryu, Gyeong-Ha;Ban, Byeong-Min;Kim, Jae-Hyeong;Son, Sang-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.258-258
    • /
    • 2013
  • 최근 건조 제품의 양질화, 고급화 및 편의화가 요구되어 이를 충족시키기 위한 새로운 건조방법이 계속 개발 되어 왔다. 이러한 방법들 중에서 저온과 진공하에서 건조가 이루어지는 진공 동결 건조는 가장 완벽한 건조 방법으로 최근 실용화 되고 있다. 진공동결건조란 건조의 한 종류로 수분을 함유한 시료를 동결시킨 후 진공펌프를 이용하여 수증기압을 3중점 이하로 낮추어 얼음을 직접 증기로 만드는 승화의 원리에 의해서 얻어진다. 분무진공동결건조의 특징은 (1) 물리적구조의 보존성, (2) 화학적인 안정성, (3) 생물학적인 활동의 보존성, (4) 제품의 높은 복원성 및 재생성이다. 따라서 분무진공동결건조 기술은 크게 진공, 분무, 동결, 건조, 멸균 등과 같은 요소기술의 복합기술이라 할 수 있다. 분말을 제조하기 위해서 진공동결건조 후 분쇄하는 방법을 사용하나 본 방법에서는 정밀화학품 제조를 위해서 분무진공동결건조 방식을 사용한다. 이를 통하여 적당한 크기인 5~10 um의 입경 제조가 가능하고, 공기동력학적인 입경이 기존 방식에 비해 작아서 허파까지의 운반효율이 1.5~2배 우수하다. 화학, 의학 분야에서의 분무동결 건조는 주로 민감한 제품, 즉 생물학적 고유성의 손상 없이 물을 제거하는데 사용되어 영구적으로 저장 가능한 상태로 보관할 수 있으며 물의 첨가로 원상태로 복구할 수 있어서 매우 각광을 받고 있다. 의약용 냉동건조 제품은 항생물질, 박테리아, 혈청, 백신, 검사 약물, 단백질을 포함하는 생물공학 제품들, 세포, 섬유, 화학제품 등이 있으며 주로 vial 또는 ampule 상태로 건조가 이루어진다.본 연구에서는 원료를 $-194^{\circ}C$의 액체질소에 분무시켜 동결된 미립자를 형성한 후 진공 및 저온상태에서얼음의 승화(sublimation)에 기반한 1차 건조와 수증기 탈착(desorption)에 기초한 2차 건조 과정으로 구성된 분무진공동결건조기를 개발하였다. 분무동결 과정의 해석을 통해 2유체식 노즐을 통해 분무된 미세 입경의 액적이 액체 질소 표면까지 도달하는 회수률, 분무 노즐의 위치, 운전 조건 및 용기의 설계의 최적화를 수행하였다. 초기 액적속도, 분무노즐의 높이, 흡입구 추가에 따른 액적 유동 및 회수의 특성을 제시하였으며 이를 통한 분사시스템 고도화 가능성을 제시하였다. 구형의 미세 입자가 적층된 제품의 동결건조 공정의 해석은 흡착승화 모델(sorption sublimation model)을 기반으로 다음과 같은 열전달, 물질전달, 상변화 모델을 고려하여 유도되었다. 분무노즐 및 냉동/진공 배기계 시작품을 개발하여, 표면의 고다공도를 갖춘 입경 3~20 m 정도의 시료를 얻을 수 있으며, 동역학적 입경 5 m 충족함을 확인하였다.

  • PDF

Analysis of Holdup Characteristics of Large and Small Bubbles in Three-Phase Fluidized Beds by using a Dynamic Gas Disengagement Method (삼상유동층에서 동력학적 기체유출 측정방법에 의한 큰 기포와 작은 기포의 체류량 특성 해석)

  • Lim, Hyun Oh;Lim, Dae Ho;Seo, Myung Jae;Kang, Yong;Jung, Heon;Lee, Ho Tae
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.605-610
    • /
    • 2011
  • Phase holdup characteristics of relatively large and small bubbles were investigated in a three-phase(gasliquid-solid) fluidized bed of which diameter was 0.105 m(ID) and 2.5 m in height, respectively. Effects of gas(0.01~0.07 m/s) and liquid velocities(0.01~0.07 m/s) and particle size($0.5{\sim}3.0{\times}10^{-3}m$) on the holdups of relatively large and small bubbles were determined. The holdups of two kinds of bubbles in three phase fluidized beds were estimated by means of static pressure drop method with the knowledge of pressure drops corresponding to each kind of bubble, respectively, which were obtained by dynamic gas disengagement method. Dried and filtered air which was regulated by gas regulator, tap water and glass bead of which density was $2500kg/m^3$ were served as a gas, a liquid and a fluidized solid phase, respectively. The two kinds of bubbles in three-phase fluidized beds, relatively large and small bubbles, were effectively detected and distinguished by measuring the pressure drop variation after stopping the gas and liquid flow into the column as a step function: The increase slope of pressure drop with a variation of elapsed time was quite different from each other. It was found that the holdup of relatively large bubbles increased with increasing gas velocity but decreased with liquid velocity. However, the holdup showed a local minimum with a variation of size of fluidized solid particles. The holdup of relatively small bubbles increased with an increase in the gas velocity or solid particle size, while it decreased slightly with an increase in the liquid velocity. The holdups of two kinds of bubbles were well correlated in terms of operating variables within this experimental conditions, respectively.