• Title/Summary/Keyword: 공급배관

Search Result 218, Processing Time 0.028 seconds

Study on Dynamics Modeling of Pogo Suppression Device (PSD) (포고억제장치(PSD) 동특성 모델링에 관한 연구)

  • Lee, Jun-Kyoung
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.11 no.5
    • /
    • pp.23-30
    • /
    • 2007
  • The effectiveness of a pogo suppression device (PSD) on the response of piping system simulating the propellant supply lines of the rocket engines was investigated experimentally by other researchers. In this study, the simplified analytical model was made, and the key parameters which are difficult to derive theoretically were identified in combination with the previous experimental work. In other words, the flow transient equations for a PSD system and the key parameters used to decide the instability of the system from the linearized transfer function including inertance, compliance, and resistance were derived. From the analysis, the values of key parameters could be determined from the experimental results.

Development of the Spherical Flange used in a Cryogenic High Pressure Pipe (극저온 고압 배관용 구형 플랜지 개발)

  • Moon, Il-Yoon;Moon, In-Sang;Yoo, Jae-Han;Lee, Soo-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2011.04a
    • /
    • pp.283-288
    • /
    • 2011
  • The spherical flange was designed to apply to a cryogenic high pressure pipe of the Liquid Rocket Engine. It is designed that the spherical flange is able to be assembled and kept airtight upto $2.5^{\circ}$ of the axial misalignment between the combined components. It increases the degree of freedom of the engine assembly. The spherical flange is composed of a ball and socket joint, a metal seal and spherical type bolts, washers. The prototype was verified by leak test at the room temperature and the cryogenic temperature. Additionally the strength test and the destructive test were performed at the room temperature.

  • PDF

Development of the Spherical Flange Used in a Cryogenic High Pressure Pipe (극저온 고압 배관용 구형 플랜지 개발)

  • Moon, Il-Yoon;Moon, In-Sang;Yoo, Jae-Han;Lee, Soo-Young
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.15 no.3
    • /
    • pp.64-69
    • /
    • 2011
  • The spherical flange was designed to apply to a cryogenic high pressure pipe of a liquid rocket engine. It is designed that the spherical flange is able to be assembled and kept airtight up to $2.5^{\circ}$ of the axial misalignment between the combined components. It increases the degree of freedom of the engine assembly. The spherical flange is composed of a ball and socket joint, a metal seal, spherical type bolts and washers. The prototype was verified by leak test at the room temperature and the cryogenic temperature. Additionally the strength test and the destructive test were performed at the room temperature.

A Study on Process Management Method of Offshore Plant Piping Material using Process Mining Technique (프로세스 마이닝 기법을 이용한 해양플랜트 배관재 제작 공정 관리 방법에 관한 연구)

  • Park, JungGoo;Kim, MinGyu;Woo, JongHun
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.56 no.2
    • /
    • pp.143-151
    • /
    • 2019
  • This study describes a method for analyzing log data generated in a process using process mining techniques. A system for collecting and analyzing a large amount of log data generated in the process of manufacturing an offshore plant piping material was constructed. The analyzed data was visualized through various methods. Through the analysis of the process model, it was evaluated whether the process performance was correctly input. Through the pattern analysis of the log data, it is possible to check beforehand whether the problem process occurred. In addition, we analyzed the process performance data of partner companies and identified the load of their processes. These data can be used as reference data for pipe production allocation. Real-time decision-making is required to cope with the various variances that arise in offshore plant production. To do this, we have built a system that can analyze the log data of real - time system and make decisions.

Limit Loads for Circular Wall-Thinned Feeder Pipes Considering Bend Angle (굽힘각도를 고려한 원형 감육이 발생한 중수로 피더관의 한계하중)

  • Bae, Kyung-Dong;Je, Jin-Ho;Kim, Jong-Sung;Kim, Yun-Jae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.36 no.3
    • /
    • pp.313-318
    • /
    • 2012
  • In CANDU, feeder pipes supply heavy water to pressure tube and steam generator. Under service conditions, Flow-Accelerated Corrosion (FAC) produces local wall-thinning in the feeder pipes. The wall-thinning in these pipes affects the integrity of the piping system, as verified in previous research. This paper provides limit loads for wallthinned feeder pipes with $45^{\circ}$ and $60^{\circ}$ bend angles, and proposes an equation that predicts the limit loads for wallthinned feeder pipes with arbitrary bend angles. On the basis of finite element limit analyses, limit loads are obtained for wall-thinned feeder pipes under in-plane bending and internal pressure. There are two cases of in-plane bending: the in-plane closing direction and the in-plane opening direction. The material is considered the effect of the large deformation, so an elastic-perfectly-plastic material is assumed in the calculations.

Study on real time monitoring to detect third party damage using vibration signal (진동신호를 이용한 타공사 조기 감시 기술 연구( I ))

  • Cho S.H.;Jeon K.S.;Park K.W.;Cho Y.B.;Li S.Y.;Kyo Y.T.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.1 s.9
    • /
    • pp.1-8
    • /
    • 2000
  • Third party damage is one of the causes intrimiting the safety of a buried pipelines and it is very important to detect third party damage on pipelines as soon as possible. The purpose of this study is whether third-party damage can be detected by accelerometer sensor and how far the third-party damage signal can propagate. And a pilot experiment was carried out in order to find third-party damage location. As a result, the detected signal's spectum is high frequency at short distances, as the distance is far, the signals in high frequency range are attenuated and those in low frequency range remain. It was also proved that third-party damage within 5.3km distance can be detected by monitoring vibration signals.

  • PDF

Numerical Analysis of Off-Gas Flow in Hot Area of the Vitrification Plant (유리화공정 고온영역에서의 방사성 배기체 유동해석)

  • Park, Seung-Chul;Kang, Won-Gu;Hwang, Tae-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.213-220
    • /
    • 2007
  • Appropriate numerical models for the simulation of off-gas flow in hot area of the vitrification plant have been developed in this study. The models have been applied to analyze the effect of design parameters of real plant and numerical analyses have been performed for CCM(Cold Crucible Melter), pipe cooler and HTF(High Temperature Filter). At first, the effect of excess oxygen and the ratio of oxygen distribution on combustion characteristics in the CCM has been studied. Next, solidification behavior of radio nuclide in the pipe cooler has been numerically modeled and scrutinized. Finally, flow pattern in accordance with the location of off-gas entrance of the HTF has been compared.

  • PDF

Numerical Analysis of Off-Gas Flow in Hot Area of the Vitrification Plant (유리화공정 고온영역에서의 방사성 배기체 유동해석)

  • Park Seung-Chul;Kim Byong-Ryol;Shin Sang-Woon;Lee Jin Wook;Kang Won Gu;Hong Seok Jin
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11a
    • /
    • pp.69-78
    • /
    • 2005
  • Appropriate numerical models for the simulation of off-gas flow in hot area of the vitrification plant have been developed in this study. The models have been applied to analyze the effect of design parameters of real plant and numerical analyses have been performed for CCM(Cold Crucible Melter), pipe cooler and HTF(High Temperature Filter) At first, the effect of excess oxygen and the ratio of oxygen distribution on combustion characteristics in the CCM has been studied. Next, solidification behavior of radio nuclide In the pipe tooler has been numerically modeled and scrutinized. Finally, flow pattern In accordance with the location of off-gas entrance of the HTF has been compared.

  • PDF

Analysis of the Impact of Fire and Explosion Accidents due to LNG Leaks in the LNG Re-gasification Process (LNG 재기화 공정에서 LNG 누출에 따른 화재 및 폭발사고의 피해영향 분석)

  • Lee, Yoon-Ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.825-833
    • /
    • 2018
  • In this study, one calculated the range of damage to the combustion characteristics according to the composition of LNG and the size of leaking holes, and analyzed the damage effect in case of leakage accidents caused by pipe damage in the re-gasification process for the LNG supply system. In order to confirm the combustion characteristics according to LNG composition, there was no significant difference in the result of risk analysis by LNG-producing areas. However, the higher the methane content of the components, the lower the risk of flash fire, hazardous areas of overpressure due to explosion, and thermal radiation damage caused by jet fire. In addition, one investigated the effect of leakage, holes, and ruptures on the risk range and explosions according to the size of the pipe-leakage hole. Also, the influence of overpressure and the range of damage from radiant heat could be predicted. One confirmed the effect of LNG composition and pipe-leakage size on fire and explosion.

A Presentation on the Manual Hydraulic Calculation Method of the Loop Type Fire Sprinkler System (Loop형 스프링클러 설비의 수리계산 방법에 대한 제시)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.73-79
    • /
    • 2015
  • There are three kinds of design method of the fire sprinkler systems. Grid type is connected all branch as a trapezoid. Loop type is connected cross-mains like circle. The last one is a tree type most commonly used. Grid type needs computer program to calculate the friction loss and flow rate apart from very simple form. In loop type, manual calculation is possible. Design engineer can draw up and calculate the demands without computer program. Because water supplies two direction in loop type, friction loss is smaller than tree type. Water distribution in operation area is uniform because of the small differences of sprinklers discharge pressure. Loop type is superior to tree type in respect of total pressure and flow rate. Using the small diameter pipe, the labor and construction cost will be decreased in the end. Loop type sprinkler design is rarely laid out because design engineers don't know the method. This paper is intended to inform that the loop type is better than the tree type in performance and economic point of view. And also this paper intend to use the loop type easily and widely.