• Title/Summary/Keyword: 공간적으로 보강된 복합재

Search Result 12, Processing Time 0.011 seconds

Stiffness Prediction of Spatially Reinforced Composites (공간적으로 보강된 복합재료의 강성예측)

  • 유재석;장영순;이상의;김천곤
    • Composites Research
    • /
    • v.17 no.5
    • /
    • pp.25-38
    • /
    • 2004
  • In this study, the stiffness of spatially reinforced composites (SRC) are predicted by using superposition of a rod and matrix stiffnesses in an arbitrary direction. To confirm the predicted values, the material properties of SRC are measured. The predicted values from the volume average of stiffness matrix are consistent with the tested values in a rod direction, but are inconsistent in an off-rod direction while reverse is true fur the volume average of compliance matrix. Therefore, the harmony function from superposition of stiffness and compliance matrix is introduced. The predicted values from the harmony function are consistent with the tested values in both the rod and the off-rod directions.

Strength Prediction of Spatially Reinforced Composites (공간적으로 보강된 복합재료의 강도예측)

  • 유재석;장영순;이상의;김천곤
    • Composites Research
    • /
    • v.17 no.5
    • /
    • pp.39-46
    • /
    • 2004
  • In this study, the strength of spatially reinforced composites (SRC) are predicted by using stiffness reduction for each structural element composed of a rod stiffness in each direction and a matrix stiffness proportional to its rod volume fraction. Maximum failure strain criteria is applied to rod failure, and modified Tsai-Wu failure criteria to matrix failure. The material properties composed of the tensile failure strain of a rod, the compressive failure strain of 3D SRC, the tensile and compressive strength of the 3D SRC in the $45^{\cir}$ rotated direction from a rod and the shear strength of the 3D SRC are measured to predict the SRC strength. The strength distributions of the 3D/4D SRC in rod and off-rod direction have the largest and the smallest values, respectively. A variable load step is selected to increase an efficiency of strength distribution calculation. Uniform load step is applied when a load history is needed. The results of compressive strength from analysis and experiment show the 18 % difference though the initial slop is coincident with each other.

Evaluation of Shear Behavior of Reinforced Concrete Beams with FRCM Composites with Different Textile Grid Types (텍스타일 그리드 종류가 다른 FRCM 복합재를 적용한 철근콘크리트 보의 전단거동 평가)

  • Hyun Kong;Minsu Jo;Sua Lim;Donghwan Kim;Kilhee Kim
    • Land and Housing Review
    • /
    • v.15 no.3
    • /
    • pp.141-151
    • /
    • 2024
  • This paper presents the results of an experimental study to evaluate the shear behavior of reinforced concrete beams reinforced with FRCM composites using different types of textile grids. It was found that the shear behavior of reinforced concrete beams with FRCM composites was observed by comparing the strains measured in the stirrups and textile grids. It was found that the ultimate strength of the strengthened specimens increased compared to the basic specimens, and the failure mode at ultimate strength changed from shear failure to bending failure. When the shear strength design values of the KDS 14 20 22 and AIJ ultimate strength types were compared with the actual experimental values, it was found that the AIJ ultimate strength type was more accurate. In addition, the shear contribution of FRCM composites in the A and T models was compared, and the results showed that both models had similar trends. Reflecting these results, it is recommended that further studies should be conducted to calculate the shear performance of beam members with FRCM composites and the shear contribution of FRCM composites by using the stirrup reinforcement ratio and the type of textile grid as variables.

Prediction of Thermal Conductivity of Spatially Reinforced Composites (다방향으로 입체 보강된 복합재의 열전도계수 예측)

  • 이상의;유재석;김천곤;홍창선;김광수
    • Composites Research
    • /
    • v.14 no.3
    • /
    • pp.57-68
    • /
    • 2001
  • This paper predicted the thermal conductivity of spatially reinforced composites(SRC) by applying the volume averaging method and the thermal resistance method. The former method employs existing micro-mechanical theories and conventional transformation rules to obtain the constitutive relations for the unit cells of the composites and the latter one uses the analogy between the diffusion of heat and electrical charge. To verify the theoretical predictions, the thermal conductivity of 4-D(dimensional) SRC was examined experimentally. The comparison of the numerical results with those measured by the experiment showed good agreement.

  • PDF

Prediction of Mechanical Properties for Spatially Reinforced Composites (공간적으로 보강된 복합재의 기계적 물성치 예측)

  • 유재석;김천곤;홍창선;김광수
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.177-182
    • /
    • 2000
  • This paper predicted the equivalent stiffness of spatially reinforced composites (SRC) using the volume average of a fiber rod and matrix stiffness, and the strength of SRC using the stiffness reduction and the modified Tsai-Wu composite failure theory. Those equivalent engineering constants are used to analyze the mechanical behavior and the failure of SRC structures. Because the distribution of equivalent engineering constants is varying with the change in SRC shape, we made a program that predicts engineering constants of SRC. Both 3-D and 4-D SRC show the smallest tensile modulus and the largest shear modulus at the maximum rotated direction from each rod. Also the strength properties show the same tendency.

  • PDF

An Performance Evaluation of Seismic Retrofitted Column Using FRP Composite Reinforcement for Rapid Retrofitting (긴급시공이 가능한 FRP 복합재료 보강재로 보강된 기둥의 내진성능평가)

  • Kim, Jin-Sup;Seo, Hyun-Su;Lim, Jeong-Hee;Kwon, Min-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.1
    • /
    • pp.47-55
    • /
    • 2014
  • As increasing number of large-size earthquake around Korean peninsula, many interests have been focused to the earthquake strengthening of existing structures. The brittle fracture of Non-seismic designed columns lead to full collapse of the building. In the past, cross-sectional extension method, a steel plate reinforcing method and fiver-reinforced method are applied to Seismic Rehabilitation Technique mainly. However, the reinforcement methods have drawbacks that induce physical damage to structures, large space, long duration time. So, in this study, performance evaluation of previously developed FRP seismic reinforcement which do not induce physical damage and short duration time was enforced. The specimens were constructed with 80% downscale. FRP seismic reinforcement are manufactured of glass fiber or aluminum plate with holes and glass fiber. From the experiment results, seismic performance of specimens which reinforced with FRP seismic reinforcement were increased.

A numerical study of pillar reinforcing effect in underground cavern underneath existing structures (지하공간하부 지하저류공동에서의 필라 보강효과에 관한 수치해석적 연구)

  • Seo, Hyung-Joon;Lee, Kang-Hyun;Han, Shin-In;Lee, In-Mo
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.5
    • /
    • pp.453-467
    • /
    • 2012
  • Usage of underground space is increasing at metropolitan city. More than 90% of flood damages have occurred at downtown of metropolitan cities. In order to prevent and/or minimize the flood-induced damage, an underground rainwater detention cavern was proposed to be built underneath existing structures. As for underground caverns to be built for flood control, multi-caverns will be mostly adopted rather than one giant cavern because of stability problem. Because of the stress concentration occurring in the pillars between two adjacent caverns, the pillar-stability is the Achilles' heel in multi-caverns. So, a new pillar-reinforcing technology was proposed in this paper for securing the pillar-stability. In the new pillar-reinforcing technology, reinforced materials which are composed of a steel bar and PC strands are used by applying pressurized grouting, and then, by applying the pre-stress to the PC strands and anchor body. Therefore, this new technology has an advantage of utilizing most of the strength that the in-situ ground can exert, and not much relying on the pre-cast concrete structure. The main effect of the pressurized grouting is the increase of the ground strength and more importantly the decrease of stress concentration in the pillar; that of the pre-stress is the increase of the ground strength due to the increase of the internal pressure. In this paper, ground reinforcing effects were verified the stress change in pillar is obtained by numerical analysis at each construction stage. From these results, the effects of pressurized grouting and pre-stress are verified.

A Study on the Standardized Finite Element Models for Carbody Structures of Railway Vehicle Made of Sandwich Composites (샌드위치 복합재 적용 철도차량 차체 구조물의 표준유한요소모델 제시 연구)

  • Jang, Hyung-Jin;Shin, Kwang-Bok;Ko, Hee-Young;Ko, Tae-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.382-388
    • /
    • 2010
  • This paper describes the standardized finite element model for carbody structures of railway vehicle made of sandwich composites. Recently, sandwich composites were widely used to railway vehicle due to the improvement of energy efficiency, high specific stiffness and strength, weight reduction and space saving in korea. Therefore, structural integrity should be verified using finite element analysis prior to the manufacture of composite railway vehicle. The standardized finite element model for composite carbody structures was introduced through comparing the results of real structural test under vertical, compressive, twisting load and natural frequency test of various railway vehicles in this study. The results show that the quadratic shell element is suitable to model the reinforced metal frame used to improve the flexural stiffness of sandwich panel compared to beam element, and layered shell and solid element are recommended to model the skin and honeycomb core of sandwich panel compared to sandwich shell element. Also, the proposed standard finite element model has the merit of being applied to crashworthiness problem without modifications of finite element model.

Analytical Study for Optimal Reinforcement Amount and Development of FRP Seismic Reinforcement that can be Emergency Construction (긴급시공이 가능한 FRP 내진보강재 개발 및 최적 보강량 산정을 위한 해석적 연구)

  • Kim, Jin-Sup;Kwon, Min-Ho;Seo, Hyun-Su;Lim, Jeong-Hee;Kim, Dong-Young
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.17 no.5
    • /
    • pp.136-145
    • /
    • 2013
  • Social interest in the seismic retrofit of the structure is growing massive earthquake that occurred recently. The brittle fracture of Non-seismically designed Columns lead to full collapse of the building. In the past, cross-sectional expansion method, a steel plate reinforcing method is applied mainly in recent years, fiber-reinforced method utilizing the advantages of the composite material are preferred. However, the reinforcement methods such as this, there is a drawback to induce physical damage to structures, and time consuming work space is large. IIn this study, FRP seismic reinforcement was developed using the Aluminum connector and the composite material (Glass Fiber Reinforced Polymer). Then, the optimum quantities of FRP seismic reinforcement was determined using a nonlinear finite element analysis program. Finally, the quantity decision process through the design and analysis of FRP reinforcement was suggested.

Dome Shape Design and Performance Evaluation of Composite Pressure Vessel (복합재 압력용기의 돔 형상 설계 및 성능 평가)

  • Hwang, Tae-Kyung;Park, Jae-Beom;Kim, Hyoung-Geun;Doh, Young-Dae;Moon, Soon-Il
    • Composites Research
    • /
    • v.20 no.4
    • /
    • pp.31-41
    • /
    • 2007
  • Dome shape design methods of Filament Winding (FW) composite pressure vessel, which can suggest various dome contour according to the external loading conditions, were investigated analytically and numerically. The performance indices(PV/W) of the pressure vessels with same cylinder radius and boss opening but different dome shape were evaluated by finite element analysis under the internal pressure loading condition. The analysis results showed that as the dome shape becomes flat, the performance index decreases significantly due to the reduced burst pressure. Especially, for the case of the high value of the parameter ro, the ratio between the radii of the cylinder part and the boss opening, the flat dome is disadvantageous in the aspect of the weight reduction, and additional reinforcing dome design technique should be required to increase the burst pressure. For example, above ro=0.54 condition, the dome shape change according to the loading condition could cause the low burst pressure and increase of composite weight in dome region and is not recommendable except for the special case that maximum inner volume or sufficient space between skirt and dome is the primary design objective. However, at ro=0.35, the dome shape change brings not so significant differences in the performance of FW vessel.