• Title/Summary/Keyword: 골 용해

Search Result 455, Processing Time 0.022 seconds

A Case of Nasal Cryptococcosis in a Domestic Shorthair Cat (코리안 쇼트헤어 고양이에서 발생한 크립토코쿠스 감염증 의심 1증례)

  • Lee, Jin Soo;Kim, Hyun Wook;Choi, Ul Soo
    • Journal of Veterinary Clinics
    • /
    • v.30 no.2
    • /
    • pp.115-118
    • /
    • 2013
  • An 8-year-old spayed female domestic shorthair cat was presented with a chief complaint of chronic nasal discharge and dyspnea. Physical examination revealed pyohemorrhagic nasal discharge, inspiratory dyspnea and stertor, and an enlarged right mandibular lymph node. Abnormalities of blood works and serum chemistry included mildly increased hematocrit, and globulin concentration. Serologic tests for FeLV and FIV, and a panel of polymerase chain reaction tests for Chlamydophila felis, Feline Calicivirus, Herpesvirus, Bordetella, Mycoplasma felis, and H1N1 influenza was all negative. Only radiographic finding showed increasing soft tissue density in the right nasal cavity and computed tomography disclosed soft tissue/fluid opacification in the right nasal cavity, paranasal sinus, and pharyinx along with slight deviation to the right of the osseous nasal septum. Focal lysis of ventral nasal septum was also suspected in CT scan. Cytological evaluation of fine needle aspirate smears of the enlarged mandibular lymph nodes revealed numerous fungal yeasts having variably thick capsule both extracellularly and intracellularly with low numbers of macrophages. Some yeasts showed narrow based budding, which was a consistent finding with Cryptococcus organisms. Serum protein electrophoresis was a polyclonal consistent with chronic infection and serum was submitted for a fungal serology panel test. In serologic tests Cryptococcus antigen titer was 1 : 32,768. In vitro culture was unsuccessful. Treatment was initiated with administration of fluconazole, clindamycin, and tocopherol. Clinical signs resolved within 3 days after the initial treatment. The cat was discharged and scheduled for periodic evaluation and continued therapy, but was lost to follow-up thereafter.

Temporary Threshold Shift of Vibration Sensation by Dental Handpiece (치과용 핸드피스에 의한 일시적 진동감각역치 변화)

  • Kim, Seong-Ah;Lee, Jong-Young;Kim, Doo-Hie;Park, Soon-Woo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.765-771
    • /
    • 1995
  • This study was performed to investigate the possibility of temporary threshold shift (TTS) of vibration sense could induced by exposure to high-frequency vibration or by work position taking by dentists in drilling or polishing. The vibratory perception thresholds (VPT) of 28 healthy men were measured on the index fingertip pulp of dominant hand at 250 Hz. The vibrating tool used in test was a low-speed handpiece of 34,000 rpm. For the TTS test, the dominant hand was exposed to high-frequency vibration and to work position for five minutes, respectively. The VPTs before and after vibratory exposure were $23.5{\pm}3.5dB,\;30.8{\pm}4.2dB$, respectively and VPT after work position was $23.7{\pm}4.6dB$. The difference between before and after vibartory exposure was statistically significant (p<0.001). The correlation of height, weight and BMI with baseline VPTs was not statistically significant. Also, there was no difference of VPTs by smoking. These results suggest that high-frequency vibration from dental handpieces might cause the impairment of vibration sensation.

  • PDF

Quantitative Changes of Hydroxycinnamic Acid Derivatives and Anthocyanin in Corn (Zea mays L.) According to Cultivars and Heat Processes (옥수수의 품종별 및 가공별 Hydroxycinnamic Acid 유도체 및 Anthocyanin 색소의 함량 변화)

  • Yu, Myeong-Hwa;Kim, Eun-Ok;Choi, Sang-Won
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.6
    • /
    • pp.843-852
    • /
    • 2010
  • Hydroxycinnamic acid derivatives (HADs) and anthocyanins in corn (Zea mays L.) have recently been reported to have anticarcinogenic, anti-hypertensive, antidiabetic, antifungal, antioxidant, and anti-melanogenic activities. Five HADs and anthocyanins in corn were quantified by HPLC according to cultivars and heat processes. In addition, major anthocyanin of a black waxy corn was isolated and identified by several instrumental analysis, and its content was also quantified by HPLC according to heat processes. Of the ten corn cultivars, five waxy corn cultivars had moderate five HADs contents except "Baksa" waxy corn with higher two free cinnamic acids (FCAs), p-coumaric and ferulic acids. In contrast, three dent corn cultivars contained higher levels of three polyamine conjugates (PCs), CFP, DCP and DFP, and especially "P3394" had the highest amount of the three PCs. Two sweet corn cultivars had generally intermediate HADs levels between waxy and dent corn cultivars. Of the three colored-waxy corns, a black Mibaek waxy corn had the highest anthocyanin content. During heat processes, levels of two FCAs in the black waxy corn generally increased, whereas no significant change on three PCs contents was observed except the puffing process. Roasting, retort and puffing processes significantly increased two FCAs and especially, the puffed black waxy corn had the highest amount of FCAs. Meanwhile, most heat treatments except retort process, considerably decreased total anthocyanin contents, and especially the puffed black waxy corn had nearly no anthocyanin. Level of one major anthocyanin, pelargonidin 3-glucoside (P3G) isolated from a black waxy corn was appreciably decreased by heat treatments except retort process, which greatly increased P3G content. These results suggest that the retorted black waxy corn may be a promising high quality functional corn product.

Physicochemical Characteristic of the Silkworm Sericin Cocoon (세리신잠견의 이화학적 특성)

  • 김수연;손해룡;배도규;김정호
    • Journal of Sericultural and Entomological Science
    • /
    • v.45 no.1
    • /
    • pp.10-17
    • /
    • 2003
  • This study was carried out to analyze physicochemical characteristics of sericin cocoon from silkworm, Bombyx mori. The degumming loss increased with increasing treatment time up to 2 hr, and temperature up to 130$^{\circ}C$. At 130$^{\circ}C$, degumming loss of Nd-s jam and Nd$\^$H/ jam were 100% while that of Baegok jam was 24%. Nd-s jam and Baegok jam ha high glycine content of 29.1∼46.3 mol% where as Nd$\^$H/ jam had high serine content of 32.6 mol%. Thermal denaturation temperatures were found at 218$^{\circ}C$ for Nd-s jam, 216$^{\circ}C$ for Nd$\^$H/ jam, and 218$^{\circ}C$ for Baegok jam. Before degumming, crystallinities obtained by FT-IR analysis were 44.3, 43.7, and 59.9% for Nd-s jam, Nd$\^$H/ jam, and Baegok jam respectively. After degumming, crystallinity increased to 61.8% for Baegok jam. Before degumming, crystallinitics obtained from XRD were 35.9, 33.5, and 47.2%, for Nd-s jam, Nd$\^$H/ jam, and Baegok jam. After degumming, crystallinity increased to 49.8% for Baegok jam. The molecular weight of Nd$\^$H/ jam were 9,417 in 1 hr, 3,744 in 2 hr, 4,944 in hr, and 3,910 in 6 hr.

Retrospective study of implant stability according to the implant length, diameter and position (임플란트 길이, 직경 및 식립 위치에 따른 임플란트 안정성에 관한 후향적 연구)

  • Kim, Ji-Hye;Jeon, Jin-Yong;Heo, Yu-Ri;Son, Mee-Kyoung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.269-275
    • /
    • 2013
  • Purpose: The aim of this retrospective study was to evaluate the influence of implant diameter, length and placement to implant stability. Materials and methods: Total 90 implants (US II plus$^{TM}$, Osstem co, Busan, Korea) of 72 patients were determined as experimental samples. The factors of diameters(${\phi}$ 4 mm, ${\phi}$ 5 mm), lengths (10 mm, 11.5 mm, 13 mm), and implant placement (maxilla, mandible) were analyzed. The stability of the implants was measured by resonance frequency analysis (RFA) at the time of implant placement and impression taking. The difference of ISQ values according to patient's gender was evaluated by Independent t-test. ISQ values were compared between implant diameter, length and placement using one-way ANOVA and Tukey HSD test (${\alpha}=.05$). To compare ISQ values between at the time of surgery and impression taking, paired t-tests were used (${\alpha}=.05$). Results: The change of implant length did not show significant different on the ISQ value (P>.05). However, 5 mm diameter implants had higher ISQ values than 4 mm diameter implants (P<.05). Implants placed on the mandible showed significantly higher ISQ values than on the maxilla (P<.05). Conclusion: In order to increase implant stability, it is better to select the wider implant, and implants placed on mandible are possible to get higher stability than maxilla. ISQ values at impression taking showed higher implant stability than ISQ values at implant placement, it means that RFA is clinically effective method to evaluate the change of implant stability through the osseointegration. The consideration of the factors which may affect to the implant stability will help to determine the time of load applying and increase the implant success rate.

Clinical Comparison of Two Types of Hook Plate in Surgical Treatment of Acromioclavicular Dislocation - AO Hook Plate and Wolter Plate - (견봉 쇄골 관절 탈구의 수술적 치료에서 두 가지 갈고리 금속판의 임상적 비교 - AO Hook Plate와 Wolter Plate -)

  • Choi, Jea-Yeol;Kim, Eugene;Jeong, Haw-Jae;Ahn, Jin Whan;Shin, Hun-Kyu;Park, Se-Jin;Lee, Seung-Hee;Lee, Jae-Wook;Choi, Kyu-Bo
    • Clinics in Shoulder and Elbow
    • /
    • v.15 no.2
    • /
    • pp.123-129
    • /
    • 2012
  • Objective: To evaluate if acromial locking in hook plate is necessary for surgical treatment of acromioclavicular dislocation by compare Wolter plate and AO hook plate. Methods: Seventy one patients who have Rockwood type III to V acromioclavicular joint dislocation treated with AO hook plate and Wolter plate were involved. Among them, 39 patients were treated with Wolter hook plate and 32 patients with AO hook plate. The Constant-Murley score and the range of motion of shoulder joint were measured on postoperative 1st ,$3^{rd}$, $6^{th}$ and $12^{th}$ months, and the radiological complications involving plate and bone were investigated. Results: Constant-Murley score of postoperative one year were $83.2{\pm}6.8$ in AO hook plate group and $85.2{\pm}5.3$ in Wolter plate group without statistical difference (p<0.05). Faster recover of forward elevation and external rotation were examined in Wolter plate group at first and third months after surgery than those of AO hook plate group, but there were no significant difference between after six months or later after surgery. Four cases of loosen or broken screws and one case of pull-out of plate were found in Wolter plate group. Seven cases of subacromial bony erosion and one periprosthetic fracture were found in AO hook plate group. Conclusion: Although clinical outcomes of both two methods were same, no matter if acromial locking system was or not. More radiological complication of plate and bone were found in AO hook plate than that of Wolter plate. However also had disadvantage like larger incision during surgery.

Influence of crestal module design on marginal bone stress around dental implant (임플란트 경부 디자인이 변연골 응력에 미치는 영향)

  • Lim, Jung-Yoel;Cho, Jin-Hyun;Jo, Kwang-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.3
    • /
    • pp.224-231
    • /
    • 2010
  • Purpose: This study was to investigate how the crestal module design could affect the level of marginal bone stress around dental implant. Materials and methods: A submerged implant of 4.1 mm in diameter and 10 mm in length was selected as baseline model (Dentis Co., Daegu,Korea).A total of 5 experimental implants of different crestal modules were designed (Type I model : with microthread at the cervical 3 mm, Type II model : the same thread pattern as Type I but with a trans-gingival module, Type III model: the same thread pattern as the control model but with a trans-gingival module, Type IV model: one piece system with concave transgingival part, Type V model: equipped with beveled platform). Stress analysis was conducted with the use of axisy mmetric finite element modeling scheme. A force of 100 N was applied at 30 degrees from the implant axis. Results: Stress analysis has shown no stress concentration around the marginal bone for the control model. As compared to the control model, the stress levels of 0.2 mm areas away from the recorded implant were slightly lower in Type I and Type IV models, but higher in Type II, Type III and Type V models. As compared to 15.09 MPa around for the control model, the stress levels were 14.78 MPa, 18.39 MPa, 21.11 MPa, 14.63 MPa, 17.88 MPa in the cases of Type I, II, III, IV and V models. Conclusion: From these results, the conclusion was drawn that the microthread and the concavity with either crestal or trans-gingival modules maybe used in standard size dental implants to reduce marginal bone stress.

The Evaluation of External Radiation Exposure dose rate for Radium-223 Dichloride (Radium-223 Dichloride의 외부 방사선량의 평가)

  • Cho, Seong Wook;Yoon, Seok Hwan;Seung, Jong Min;Kim, Tae Yub;Im, Jeong Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.20 no.1
    • /
    • pp.28-31
    • /
    • 2016
  • Purpose $^{223}Ra-Dichloride$ is used for the medicine of castration-resistant prostate cancer (CRPC) and which emits ${\alpha}-ray$ of 28 Mev that is used for therapy. However $^{223}Ra-Dichloride$ emits ${\beta}-ray$ of 3.6% and ${\gamma}-ray$ of 1.1%(80,156,270 keV) aside from ${\alpha}-ray$ in decay. Therefore we would like to evaluate external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$. Materials and Methods We calculated external radiation expose dose rate using ${\gamma}-constant$ of $^{223}Ra-Dichloride$, $^{99m}Tc$ based on Health physics(2012). $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq were applied. external radiation expose dose rate 15 times from 1m by survey meter. Results ${\gamma}-contant$ of $^{223}Ra$, $^{99m}Tc-MDP$ from 1m distance based on Health physics(2012) is 0.0469, 0.0215. calculated value of external radiation expose dose rate was $16{\mu}Sy$, $34{\mu}Sy$ which activity is $^{223}Ra-Dichloride$ of 3.5 MBq and $^{99m}Tc-MDP$ of 740 MBq from 1 m and measured mean value of 1 m was $0.7{\mu}Sy/h$, $18{\mu}Sy/h$. Conclusion ${\gamma}-constant$ of $^{223}Ra$ is higher than $^{99m}Tc$ based on Health physics(2012). however calculated maximum external radiation expose dose rate of $^{223}Ra-Dichloride$ is lower than $^{99m}Tc$ due to actually used quantity of activity of $^{223}Ra-Dichloride$ is small. measured value of $^{223}Ra-Dichloride$ is also lower than $^{99m}Tc-MDP$. Therefore external radiation expose dose rate of ${\gamma}-ray$ of $^{223}Ra-Dichloride$ is very low.

  • PDF

Evaluation of Effective Dose in Dental Radiography (치과 방사선 검사에서 유효선량 평가)

  • Han, Su-Chul;Lee, Bo-Ram;Shin, Gwi-Soon;Choi, Jong-Hak;Park, Hyok;Park, Chang-Seo;Chang, Kye-Yong;Kim, Bo-Ram;Kim, You-Hyun
    • Journal of radiological science and technology
    • /
    • v.34 no.1
    • /
    • pp.27-33
    • /
    • 2011
  • Along with the developments of science technology, up-to-date medical radiation equipments are introduced. Those equipments has brought many progresses in diagnosing patients not only in the quantitative aspects but in the qualitative ones. Especially, in the case of dental radiography, patients can be exposed more than CT, cone beam computed tomography (CBCT). In this study, we used human phantom and TLD-100H to measure the organ dose in each dental radiography and computed the effective dose according to ICRP (International Committee for Radioactivity Prevention) 60, 103. We measured the effective dose to be 5.1 and $29.5{\mu}Sv$ in the panoramic radiography and 11.2 and $14.4{\mu}Sv$ in the cephalometric radiography respectively. We also executed the CBCT and CT test on the maxillaries and the mandibles and found the amounts of effective dose were 53.7, 209.6, 129, and $391.5{\mu}Sv$ respectively in the CBCT and $93.3{\mu}$, 139.5, 282.7 and $489.7{\mu}Sv$ in the CT test. Consequently, it was shown that the effective dose in the CBCT test was lower than one in the CT test, but was higher in both panoramic and cephalometric radiography.

Radiographic Evaluation of Stiffness of Articular Eminence in the Temporomandibular Joint(TMJ) of Korean Using Dental cone-beam CT (한국인의 측두하악관절에서 Dental cone-beam CT를 이용한 관절융기의 경사도에 대한 방사선학적 평가)

  • Oh, Sang-Chun;Han, Ji-Seok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.2
    • /
    • pp.163-173
    • /
    • 2013
  • When the mandible performs opening movement, the condyle-disk complex conducts sliding movement along the articular eminence. Thus, anatomic configuration of articular eminence is very important to normal movement of TMJ. The purpose of this study was to measure the posterior slope of the articular eminence and evaluate the effect of a pathologic bone change in the condylar head on the stiffness of articular eminence, and compare the differences of the articular eminence slope by gender and age using dental cone-beam CT. As using i-CAT Cone-Beam Computed Tomography, the CT images of 204 TMJs of 102 patients(43 men and 59 women, mean age: 37.7 years) who were diagnosed at Wonkwang University Sanbon Dental Hospital were evaluated. All images were converted into a TMJ analysis mode to observe the continuous sagittal section images and coronal section images of the joints. To observe and assess bone changes in the condyle, three dentists measured the stiffness of the articular eminence on the same images, and when two of the three dentists agreed on their reading, these results were adopted and recorded. The articular eminence slope, considering the condylar anatomic configuration, was measured in three regions, namely, lateral part, central part, and medial part of the condyle. In the cases of a normal condyle(NCBC) and a condyle(CBC) with bone change, the articular eminence slopes were $57.0^{\circ}$(NCBC) and $51.8^{\circ}$(CBC) at the medial part, $57.9^{\circ}$(NCBC) and $52.4^{\circ}$(CBC) at the central part, and $55.1^{\circ}$(NCBC) and $49.5^{\circ}$(CBC) at the lateral part of the condyle. And the articular eminence slope of the condyle with bone change demonstrated less steepness than that of normal condyle (p<0.05). The articular eminence slope showed mediolaterally that it was the steepest at the central, followed by at the medial, and at the lateral (p<0.05). There were no significant differences by the gender and the age (p.0.05).