• Title/Summary/Keyword: 골 용해

Search Result 457, Processing Time 0.032 seconds

A Study on Fabrication of 3D Dual Pore Scaffold by Fused Deposition Modeling and Salt-Leaching Method (열 용해 적층법과 염 침출법을 이용한 3 차원 이중 공 인공지지체 제작에 관한 연구)

  • Shim, Hae-Ri;Kim, Jong Young
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.12
    • /
    • pp.1229-1235
    • /
    • 2015
  • Scaffold fabrication technology using a 3D printer was developed for damaged bone tissue regeneration. A scaffold for bone tissue regeneration application should be biocompatible, biodegradable, and have an adequate mechanical strength. Moreover, the scaffold should have pores of satisfactory quantity and interconnection. In this study, we used the polymer deposition system (PDS) based on fused deposition modeling (FDM) to fabricate a 3D scaffold. The materials used were polycaprolactone (PCL) and alginic acid sodium salt (sodium alginate, SA). The salt-leaching method was used to fabricate dual pores on the 3D scaffold. The 3D scaffold with dual pores was observed using SEM-EDS (scanning electron microscope-energy dispersive spectroscopy) and evaluated through in-vitro tests using MG63 cells.

Osseointegration of Ceramics & Zirconia : A Review of Literature (세라믹과 지르코니아의 골유착에 관한 고찰)

  • Song, Young-Gyun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.3
    • /
    • pp.319-326
    • /
    • 2012
  • For many years, ceramics have been used in fixed prosthodontics for achieving optimal esthetics. but, they have another use as well. Many studies today show ceramics can be used for biomaterials. In the beginning researchers made a start in the study of aluminium oxide and sapphire for biomaterial. The appearance of Zirconia began a new phase of research. Zirconia was introduced into implantology as an alternative to titanium, because of its white color, good mechanical properties and superior biocompatibility. But it is not easy to surface treatment in comparison with titanium. To overcome the limitation, interconnected porous bodies of zirconia were fabricated by sintering technique. And the technique of coating was developed. Therefore, some zirconia implants are currently available. It is thought that Research of biomaterials as a variety of puposes for the use of zirconia is looking very promising. The purpose of this paper reviews are to evaluation of zirconia as biomaterials.

Spermiogenesis and Spermatozoal Ultrastructure of the Roundnose Flounder, Eopsetta grigorjewi (Teleostei: Pleuronectidae) (물가자미 (Eopsetta grigorjewi)의 정자변태 및 정자 미세구조)

  • AN Cheul Min;LEE Jung Sick;HUH Sung-Hoi
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.32 no.6
    • /
    • pp.730-736
    • /
    • 1999
  • The roundnose flounder's (Eopsetta grigorjewi) spermiogenesis and fine structure of the spermatozoon were examined by means of the scanning and transmission electron microscopy, During the spermiogenesis, the chromatin of the spermatid became fine granular form, and progressively condensed into many large globules, finally homogeneously condensed in the spermatozoan head. The main characteristics of the spermiogenesis were the disappearanre of Golgi complex, the appearance of microfilament the reduction of mitochondria and the appearance of Iysosome in the cytoplasm. A spermatozoon consisted of head and tail, but the acrosome was absent. The cytoplasmic collar containing seven mitochondria was observed in the posterior part of the head. The well-developed axonemal lateral fins were observed in the tail. The cross section of the axial filament showed '9+2' axonemal structure of microtubules, and the numerous vesicles were observed in the cytoplasm.

  • PDF

The Development of Pin Screws into the Bone for External Fixator (체외 고정구용 골 삽입 금속 나사 개발)

  • Choi, Y.C.;Rhee, K.M.;Na, W.H.;Song, B.S.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.2 no.1
    • /
    • pp.5-17
    • /
    • 2009
  • We developed bone-insertion pin screw that can be used for purposed treatment by combining with the external fixator which is the subsidiary tool for the healing of the fracture (open fracture of long bone, reconstruction of soft tissue and arthrodesis etc.) Furthermore, for the frist time, we succeeded in domestic-producing this screw, using specially-designed treating tool stuck on the lathe machine and abrasive blasting machine, and the post-dealing technique and process. In comparison with other foreign products, we could get more desirable results in various tests. This pin screw has 103% characteristics of the average of foreign products. Thus we'd like to introduce design techniques, post-dealing process and result of function tests.

  • PDF

Dedifferentiated Chondrosarcoma from Low Grade Chondrosarcoma (저 악성도 연골 육종에서 발생한 미분화 연골육종 - 1례 보고 -)

  • Park, Jong-Hoon;Koh, Han-Sang;Lee, Soo-Yong
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.11 no.2
    • /
    • pp.213-218
    • /
    • 2005
  • Dedifferentiated chondrosarcoma is a most highly malignant variant of chondrosarcoma and approximately 10% of chondrosarcomas dedifferentiated into more anaplastic lesions. In addition to the surgical treatment, adjuvant chemotherapy or radiation therapy has been used but with little success. Thus, the primary treatment remains wide excision and chemotherapy or radiation therapy can be used for palliation. This article shows the case of a dediffderentiated chondrosarcoma occuring in proximal femur after conservative surgical treatment of a low grade chondrosarcoma.

  • PDF

A Study about Experimental Evaluation of an Ultrasonic Surgery Unit for Bone-cutting (골 절삭용 초음파 수술기의 실험적 평가에 관한 연구)

  • Sa, Min-Woo;Shim, Hae-Ri;Ko, Tae-Jo;Lee, Jong-Min;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.1
    • /
    • pp.1-7
    • /
    • 2016
  • In the dentistry field, an ultrasonic surgery unit is widely used in bone cutting and scaling to reduce operation time and minimize hemorrhage. The purpose of this study was to evaluate bone cutting and the effect of a specimen's temperature on the two-type ultrasonic surgery unit using a handpiece moving system(HMS). A HMS, which can cut the bone, was developed to perform the experimental procedure with precision of motion control. Bone specimens were prepared from a combination of epoxy-hardener and cortical bone of bovine leg. Through the bone-cutting experiment, the cutting depth was evaluated by not only scanning electron microscopy, but also Vernier calipers. Also, the temperature distribution was measured by a thermo-graphic camera. This study may be applied methodically in various experimental evaluations on a performance test by a HMS.

Measure of Bone Age through Greulich-Pyle Method, Tanner-Whitehouse Method and Ultrasound Transonic Velocity of Inferior Radiocarpal Joint (골연령의 측정에서 Greulich-Pyle법, Tanner-Whitehouse법, 완관절 초음파 통과속도를 이용한 골연령 측정법의 비교 연구)

  • Lee, Dong-Hyung;Lee, Jin-Yong;Kim, Deog-Gon
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.22 no.2
    • /
    • pp.69-80
    • /
    • 2008
  • Objectives : The purpose of this study was to evaluate the correlation of 3 methods of bone age measurements. Methods : 102 children(49 boys, 53 girls) were involved in this study. We measured the height, weight and bone age based when they visited for the first time. We measured bone age using BoneAge of Sunlight Co.,Ltd. Two of the bone age measurement methods, Greulich-Pyle and Tanner-Whitehouse, were used to analyze the left dorsopalmar hand-wrist radiographs of 102 children who visited in Department of Pediatrics, O O University Oriental Hospital. This study was designed to investigate the correlation of the bone age between two methods. Results : The bone ages were related with age, height, weight and BMI according to this study(P<0.01). Each bone age assessment method had statistically significant correlation to each other(P<0.01). Conclusions : The ultrasound transonic velocity of inferior radiocarpal joint will become a sufficient diagnostic tool of bone age assessment if measurement error can be minimized by proper effort.

  • PDF

Development of the Osseo-integrated Implant system for Laboratory Animals (동물실험용 골융합 임플란트 시스템 개발)

  • Bae, Tae-Soo;Heo, Hyun;Kim, Shin-Ki;Mun, Mu-Seong;Ahn, Jae-Yong;Hong, Sung-Ran
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.10
    • /
    • pp.117-122
    • /
    • 2007
  • The novel implant system was developed using osseo-integration technology which enable amputee to overcome skin troubles in use of previous socket system and was evaluated in view of biomechanics, radiology, histology, and pathology. The osseo-integrated implants were designed and manufactured using CT image of canine's tibia and were applied to laboratory animals (canines). The follow-up studies were performed for 24 months with 10 canines. In radiology examination, we found that the relative low strain distribution caused medial and posterior bone resorption and then we verified them by biomechanical testing. In histological approach, the complete osseo-integration was observed through the activity of osteoblast cells around bone-implant interface and the radial outer region of bone due to peristeum reaction. Lastly in pathological aspect, the evidence of superficial infection was detected but that of deep infection was not. Therefore it is thought that infection problem will be overcome by immunity of body and good hygiene.

A Study on Temperature Changes during Bone Scaling and Cutting of Dental Ultrasonic Scaling/Surgery System (치과용 초음파 스케일러/수술기 통합 시스템의 스케일링 및 절삭 시 온도 변화에 관한 연구)

  • Sa, Min-Woo;Ko, Tae-Jo;Kim, Jong Young
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.2
    • /
    • pp.1-8
    • /
    • 2020
  • While dental clinics still use the ultrasonic scaling/surgery tool for teeth scaling and cleaning the tool's use is expanding steadily to include treatment of damaged teeth and bone tissue. In this study, a handpiece moving system (HMS) was developed to evaluate bone scaling and cutting in the field of dentistry. The HMS, through a scaling test of bone using a scaler tip, it was able to identify surface damage. Additionally, a thermos-graphic camera was used to observe the temperature distribution that occurred during the bone scaling and cutting process. Consequently, we found that increasing the working load increased the amount of surface damage. Changes in temperature distribution occurred slowly and were maintained within safety bounds for 10 minutes. Going forward, we will compare the HMS performance on scaling and cutting with other devices.

A Study on Fabrication of Inner Structure Plate with Micro Corrugated Using Press Forming (프레스 공정을 이용한 미세 골판형 내부구조재 제작에 관한 연구)

  • Choi, Doo-Sun;Je, Tae-Jin;Kim, Hyung-Jong;Kim, Bo-Hwan;Huh, Byung-Woo;Seong, Dae-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.9 s.186
    • /
    • pp.61-67
    • /
    • 2006
  • Sandwich structures, which are composed of a thick core between two faces, are commonly used in many engineering applications because they combine high stiffness and strength with low weight. Accordingly, the usage of sandwich structure is very widely applied to the aircraft, the automobile and marine industry, etc., because of these advantages. In this paper, we have investigated the buckling protection of an inner structure plate and the useful corrugated configuration for contact, and the fabrication method of the inner structure plate for large area using the continuous molding process. Also, we have guaranteed the accuracy of the molding process through the micro corrugated mold fabrication and secured the accuracy and analyzed aspect properties of the inner structure plate fabricated for a large area using the partial mold process. We have compared molding simulation according to the aspect thickness of the corrugated configuration with the molding experiment results.