• Title/Summary/Keyword: 골터널

Search Result 50, Processing Time 0.031 seconds

TUNNEL TRACTION OF IMPACTED MAXILLARY CANINES (매복된 견치의 Tunnel을 통한 교정적 견인)

  • Jeon, Jeong-Hoon;Oh, You-Hyang;Lee, Nan-Young;Lee, Sang-Ho;Lee, Chang-Seop
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.32 no.1
    • /
    • pp.33-39
    • /
    • 2005
  • The impacted maxillary canine is a common problem of which all dental practitioners should be aware. The surgical orthodontic treatment of impacted canines is replaced correction position in dental arch without periodontal damage. Many treatment possibilities have been considered for this goal; window procedure, apically positioned flap, closed eruption technique and tunnel traction. Prognosis for these treatment may be very uncertain in many case(infraosseous impacted tooth). Other steps are required to achieve a satisfactory periodontal outcome. Satisfactory results could be expected if the physiologic eruption pattern is restored by tunnel traction, because permanent tooth erupts through the gingiva near the crest of the ridge so that periodontal damage is reduced. This article report that the surgical orthodontic treatment using tunnel traction is obtained proper position and reduced periodontal damage in facially impacted maxillary canines.

  • PDF

Intraoperative and Postoperative Complications After Arthroscopic Anterior Cruciate Ligament Reconstruction Using Bone-Patellar Tendon-Bone Autograft (자가 골-슬개건-골을 이용한 관절경적 전방십자인대 재건술의 수술 중 및 수술 후 합병증)

  • Kim, Kyung-Tae;Lee, Song;Jeong, Soon-Young;Kim, Hyun-Soo;Park, Jun-Seong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.6 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • Purpose : Evaluation and analysis of the incidence and causes of intraoperative and postoperative complications after arthoscopic anterior cruciate ligament(ACL) reconstruction using bone-patella. tendon-bone (BPTB) auto graft. Materials and Methods : We reviewed 85 cases of arthroscopic ACL reconstruction using BPTB autograft which had been followed up for more than 1 year. Intraoperative complications had been recorded and corrected during the operation. Postoperative complications were analyzed and compared between 3 groups which were classified by the last follow-up period after the operation. Results : There were a few intraoperative complications including patellar fracture(1 case), contamination of harvested graft(1 case), impingement of graft(2 cases), blow-out of tile posterior wall of the femoral tunnel(1 case) and intraarticular retraction of the screw(1 case). The result of the comparison of postoperative complications among the groups shows that the incidence of anterior knee pain, donor site pain and patellofemoral crepitation were significantly decreased after 2 years. But there was no significant decrease in these complications after 3 years. Conclusion : Intraoperative complications after arthroscopic ACL reconstruction using BPTB autograft were due to incorrect technique and carelessness of the operation team, and can be prevented by improvement of surgical technique and accumulation of experience. Postoperative complication were somewhat unavoidable but gradually improved with time; hence, we should consider it for the selection of graft donor.

  • PDF

The effectiveness of MRI evaluation after anterior cruciate ligament reconstruction using hamstring tendon autograft (자가 슬괵건을 이용한 전방십자인대 재건술 후 결과 판정에 있어 MRI 검사의 유용성)

  • Kim, Jin-Goo;Kim, Young-Woo;Lee, Soo-Won;Shim, Jae-Chan;Oh, Soo-Jin
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.1
    • /
    • pp.32-39
    • /
    • 2008
  • Purpose: To evaluate the effectiveness of MRI after ACL reconstruction with femoral tunnel at 10 o'clock position. Materials and Methods: MRI findings of 29 patients after ACL reconstruction using hamstring tendon autograft were evaluated. The mean period from operation to MRI was 18.9 months($7{\sim}40$ months). Signal intensity, morphology and continuity of graft, femoral insertion, graft angle, roof impingement, cross pin breakage and position were evaluated. Those findings were compared with KT-2000, Lysholm knee score and pivot shift test. Results: There was no significant correlation between signal intensity of graft and the duration to MRI. Most common pattern of the morphology was straight, and the continuity was well-preserved. 13 cases of femoral tunnel insertion were zone 4 and 16 were zone 3. There were no roof impingement. 10 cases showed cross pin breakages, of which 5 were found at the outside of distal femoral posterior cortex. 9 showed cross pin directed posteriorly in axial view. There was no significant correlation between clinical results and cross pin breakage. Conclusion: MRI examinations after ACL reconstructions are useful to evaluate the graft status, position of the graft and cross pins. Since the direction of the cross pin is important especially in 10 o'clock femoral position, care should be taken to avoid cross pin breakage.

  • PDF

The Delayed Inflammatory Reaction after Anterior Cruciate Lligament Reconstruction with a Bioabsorbable Interference Screw Fixation - A Case Report - (생분해성 간섭나사를 이용한 전방십자인대 재건술 후 발생한 지연성 염증반응 - 증례 보고 -)

  • Lim, Hong-Chul;Noh, Kyoung-Sun;Yang, Jae-Hyuk
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.1
    • /
    • pp.87-90
    • /
    • 2006
  • The complication caused by a bioabsorbable interference screw is rare after anterior cruciate ligament reconstruction. We report a case of delayed inflammatory reaction at the tibial tunnel and femoral tunnel where the graft tendon had been fixed with a bioabsorbable interference screw ($Bioscrew^{(R)}$) for anterior cruciate ligament reconstruction using bone-patellar tendon-bone autograft.

  • PDF

Design of Femoral Tunnel Entrance to Operate Notchplasty (Notchplasty 시술을 위한 대퇴골 터널 입구 형상 설계)

  • Chung G.Y.;Kim K.T.;Lee T.H.;Ahn J.Y.;Han J.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.279-283
    • /
    • 2000
  • After ACL reconstruction. abrasion or wear of graft appeared frequently because of contact stresses between femoral tunnel and ACL. To minimize these problems. optimal shape of femoral tunnel is necessary. In this study. we evaluate friction force by degree of wear due to abrasion of soft tissue and develop 3-dimensional FEM model using ANSYS 5.5.1 version to analyze stress growths between femoral tunnel and ACL, We conclude that femoral tunnel angle must be slacked parallel to tunnel direction to minimize contact stress.

  • PDF

Anterior Cruciate Ligament Double Bundle Reconstruction with Hamstring Tendon Autografts - Technical Notes (자가 슬괵건을 이용한 전방 십자 인대 이준 다발 재건술 - 수술 술기 -)

  • Ahn, Jin-Hwan;Lee, Sang-Hak;Ahn, Hyung-Kwon;Kang, Hong-Jae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.9 no.2
    • /
    • pp.222-231
    • /
    • 2005
  • Purpose: This article describes a double-bundle ACL reconstruction technique using a five-strand hamstring tendon autograft with conventional anteromedial bundle reconstruction and additional posterolateral bundle reconstruction. Operative technique: For the tibial tunnel, the conventional single tunnel technique is performed and for the femoral tunnel, the double tunnel technique is performed with the anteromedial and posterolateral bundle. After minimal notchplasty, the anteromedial femoral tunnel is prepared with leaving one milimeter of posterior femoral cortex within the over-the-top, which if positioned at the 11-o'clock orientation for the right knee or at the 1-o'clock position for the left knee. The posterolateral femoral tunnel that is located 5 to 7 mm superior to the inner margin of the lateral meniscus anterior horn at $90^{\circ}$ of flexion is prepared with tile outside-in technique using a 4.5 cannulated reamer. The graft material for the double bundle reconstruction is made of the conventional four-strand hamstring autograft in the anteromedial bundle and of a single-strand semitendinosus tendon in the posterolateral bundle. The anteromedial bundle is fixed with using a rigid fix system on the femoral side and the posterolateral bundle is fixed to tie with the miniplate from the outside femur. Then, with the knee in $10^{\circ}\;to\;20^{\circ}$ of flexion, a bioabsorbable screw is simultaneously applied to achieve tibial fixation with tensioning of both bundles. Conclusion: A double bundle reconstruction with five-strand hamstring autograft, which is designed with a favorable conventional anteromedial bundle and an additional posterolateral bundle to restore rotation stability, seems to be a very effective method for the treatment for ACL instabilities.

  • PDF

Alternative Fixation Technique for Bony Bankart Lesion with Using Suture Anchor (봉합나사와 골터널을 이용한 골성 반카르트 병변의 고정)

  • Kim, Byung-Kook;Lee, Ho-Jae;Kim, Go-Tak;Dan, Jinmyoung
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.6
    • /
    • pp.574-578
    • /
    • 2019
  • For the treatment of a bony Bankart lesion accompanied by an acute traumatic shoulder dislocation, anatomical reduction and stable fixation of the bone fragment and glenohumeral ligament are essential to avoid chronic instability or degenerative changes. If the Bankart lesion has large bony pieces or comminuted fragments, it can be difficult to perform precise and secure fixation of the big intraarticular fragment to the fracture site because of the limited visualization of the arthroscopic procedure. In addition, in the case of the open procedure, it requires an extensive surgical dissection to access the fractured fragment, which may cause surgical approach-related morbidity, such as neurovascular complications, delayed subscapularis healing, and increased risk of stiffness. This paper describes an alternative open suture anchor technique for a large bony Bankart lesion, which was secured anatomically with squared knots after a shuttle relay through bony tunnels and adjacent soft tissue and labrum. This technique can achieve anatomical and firm fixation under direct vision, and reduce the number of surgery related morbidities.

Comparative Biomechanical Study of Stiffness on Ligamentous Attached Sites of Distal Femur - Experimental Laboratory Study on Cadaver Femora - (원위 대퇴골 인대 부착부의 강도 비교 - 사체의 대퇴골에 행한 실험적 연구 -)

  • Kwak, Ji-Hoon;Sim, Jae-Ang;Yang, Sang-Hoon;Kim, Dong-Hee;Lee, Beom-Koo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.8 no.1
    • /
    • pp.26-32
    • /
    • 2009
  • Purpose: This study was performed to compare the strength of ligamentous attached sites of cadaveric distal femur and to obtain reliable biomechanical data to use in ligamentous reconstruction or augmentation. Materials and Methods: Fifteen cadaveric distal femurs were used for this study. After measuring the bone density, 5.0 mm cannulated screw (Experiment 1) or reconstructed porcine ligament (Experiment 2) was inserted into the each ligamentous attached sites of anterior cruciate ligament (ACL), posterior cruciate ligament (PCL), medial collateral ligament (MCL) and lateral collateral ligament (LCL). In experiment 2, reconstructed porcine graft was fixed with bioabsorbable screw in ligamentous insertion sites. And we measured the maximal pullout force of each ligamentous attached sites of cadaveric distal femur. Results: Average bone mineral density was $1.205{\pm}0.137\;g/cm^2$ in experiment 1, $1.236{\pm}0.089\;g/cm^2$ in experiment 2, which showed no statistically significant differences. In experiment 1, average pull-out strength of ACL, PCL, MCL and LCL group were $519.1{\pm}111.7$ N, $638.9{\pm}144.4$ N, $169.7{\pm}56.0$ N, $225.6{\pm}61.5$ N respectively. In experiment 2, the average pull-out strength were $310.6{\pm}31.0$ N, $379.9{\pm}47.4$ N, $104.0{\pm}14.4$ N, $131.5{\pm}21.9$ N respectively. In experiment 1, there was no significant difference between ACL and PCL group and between MCL and LCL group. However, the maximal pullout strength of MCL and LCL group were significantly lower than that of ACL and PCL group (p<0.01). Experiment 2 showed the same results of experiment 1. Conclusion: Because stiffness of MCL and LCL attached sites are much lower than that of ACL and PCL attached sites, we may consider augmented fixation in ligamentous reconstructions of MCL and LCL.

  • PDF

Clinical Results of Anterior Cruciate Ligament Reconstruction Using Hamstring Tendon (슬괵건을 이용한 전방십자인대 재건술의 임상적 결과)

  • Song Eun Kyoo;Lee Keun Bae;Shin Sang Gyoo;Kim Hyun Jong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.1 no.1
    • /
    • pp.21-25
    • /
    • 2002
  • Purpose: To evaluate the clinical results after anterior cruciate ligament (ACL) reconstruction with hamstring tendon and Ligament Anchor (LA) screw, which is newly designed for fixation of graft into femur. Materials and Methods: Fifty eight patients who were followed up at least more than 2 years after ACL reconstruction with four strands of Hamstring tendon and LA screw were included in this study. The graft was fixed with LA screw at femoral tunnel and with only bioabsorbable interference screw at tibial tunnel. The mean follow-up period was 28 months. The clinical results were evaluated by physical examination and Lysholm knee score. Widening of bony tunnel and anterior laxity difference compared with normal side by instrumented anterior laxity test with Telos(R) (Telos stress device; Austin & Associates, Inc., Polston, US) were evaluated. Results: The Lysholm knee score improved from 60.0 points preoperatively to 94.0 points at last follow up. On the Lachman test, there were mild (+) instability in 16 cases, moderate (++) in 24,severe (+++) in 18 preoperatively. 50 cases were converted to negative and 8 to mild instability at postoperative follow up. On instrumented anterior laxity test with Telos(R), difference between normal and affected knee on 20 lb was 12.9 mm in average preoperatively, and was decreased to 3.1mm at last follow-up. The femoral tunnel was widened from 10.6 mm postoperatively to 12.7 mm (21.1$\%$) at follow up on antero-posterior plane and from 10.7 mm to 12.4 mm (16.5$\%$) on lateral plane. Tibial tunnels was also widened from 9.8mm to 11.8mm (20.7$\%$) on antero-posterior plane and from 9.9mm to 11.7 mm ($18.9\%$) on lateral plane. Complications were: anterior knee crepitus in 17 case, quadriceps muscle atrophy(>3 cm) in 6, penetration of screw over the lateral femoral cortex in 5, saphenous nerve paresthesia in 2.Conclusions: ACL reconstruction with hamstring tendon and LA screw was one of the choice of grafts and fixation devices in restoring knee stability and in improving clinical results with little complications such as excessive widening of bony tunnel and anterior knee pain

  • PDF

Development of a laboratory testing method for evaluating the loading capability of lattice girder (격자지보재(Lattice Girder)의 실내성능평가기법 개발)

  • Kim, Dong-Gyou;Bae, Gyu-Jin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.10 no.4
    • /
    • pp.371-382
    • /
    • 2008
  • The objective of this study is to develop the laboratory testing method for evaluating the loading capacity of lattice girder used for support in tunnel structure. 3-point flexible strength test and 4-point flexible strength test were performed on three types of lattice girder, such as $LG-50{\times}20{\times}30$, $LG-70{\times}20{\times}30$, and $LG-95{\times}22{\times}32$, mainly used in Korea. Two types of loading position for each flexible strength test were used to analyze the behavior of load-deformation. The loading distribution in the lattice girder was analyzed by means of strains measured by strain gauges attached on chords and diagonal bars. In 3-point flexible strength test, the difference of the average of maximum flexible strength according to loading position had the range from 10% to 33%. In 4-point flexible strength test, the average of maximum flexible strength according to loading position was almost no difference. The difference between the average of maximum flexible strengths obtained from 3-point and 4-point flexible strength tests was from 13.56 to 31.55%. The load applied on the lattice girder was concentrated to the main chord in 3-point flexible strength test. The load applied on the lattice girder in 4-point flexible strength test was distributed to three chords and diagonal bars.

  • PDF