• Title/Summary/Keyword: 골조성

Search Result 380, Processing Time 0.035 seconds

The Experimental Studu on the P-Δ Influence of Weak Beam Unbraced Frames (보항복형 비가새 골조의 PΔ 영향에 관한 실험적 연구)

  • Kim, Hee Dong;Park, Sang Chul;Lee, Myung Jae
    • Journal of Korean Society of Steel Construction
    • /
    • v.13 no.4
    • /
    • pp.363-372
    • /
    • 2001
  • The objective of this study is to evaluate the $P-{\Delta}$ effect in the case of weak beam unbraced frames by experimental approach. To evaluate $P-{\Delta}$ effect, four specimens were tested under monotonic loading condition. The parameters of tests are the stiffness of column and the axial load ratio. The results show that the value of axial load affects frame stability because $P-{\Delta}$ effects promote the yielding of beam. The maximum lateral load increases in proportion to the increment of column stiffness and rotational stiffness of supports, The collapse mechanism of weak beam unbraced frames is stably formed in the condition of low axial load ratio. The $B_2$ factor of limit state design code does not properly consider the $P-{\Delta}$ effect in inelastic region.

  • PDF

Inelastic Behavior of Reinforced Concrete Frame Structure with Shear Strength of Masonry Wall (조적벽의 전단강도를 고려한 철근콘크리트골조의 비탄성 거동)

  • Yoon, Tae-Ho;Kang, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.9
    • /
    • pp.4216-4222
    • /
    • 2011
  • In this study the inelastic behavior of the existing school buildings with infilled masonry walls is analysed by pushover method. The shear stiffness and strength of masonry wall is calculated from the prior experimets and verified by inelastic analysis. The height of infilled masonry wall affects the structural behavior. The higher the masonry wall height, the higher the initial shear stiffness and strength of masonry wall. As the cracks are developed, the strength of masonry wall is much decreased. The proposed inelastic analysis method shows similar results with the experiments and can be used as inelastic analysis model of reinforced concrete buildings with infilled masonry walls.

Predicting the Role of Osteal Macrophages and Osteocytes in Bone Tissue Network Using a Mathematical Modeling (수학적 모델링을 이용한 골조직 세포 네트워크에서 Osteal Macrophage와 골세포의 역할 예측)

  • Hwang, Soo-Jeong
    • Journal of dental hygiene science
    • /
    • v.18 no.2
    • /
    • pp.130-135
    • /
    • 2018
  • The aim of this study was to investigate the role of osteal macrophages (osteomac) and osteocytes in bone remodeling using a mathematical model. We constructed the bone system with pre-osteoblasts, osteoclasts, osteocytes, and osteomac. Each link of the parameters and ordinary differential equations followed the Graham's model in 2013 except for the parameters of osteomac signaling and osteocytes signaling to link preosteoblasts and osteoblasts. We simulated the changes in each cell and bone volume according to the changes in the parameters of osteomac signaling and osteocytes signaling. The results showed bone volume was unstable and decreased gradually when the effectiveness of osteocytes and osteomac dropped below a certain level. When the parameters of osteomac signaling and osteocytes signaling to link preosteoblasts and osteoblasts had a value less than 1, bone volume increased with the increase in the parameter of osteomac signaling to link preosteoblasts and osteoblasts. Moreover, although the parameter of osteocytes signaling to link preosteoblasts and osteoblasts, increased in case of a small parameter of osteomac signaling, bone volulme decreased. If the parameters of osteomac signaling to link preosteoblasts and osteoblasts were over a certain level, bone volume was positively maintained, despite the parameter of osteocyte signaling to link preosteoblasts and osteoblasts. We suggested the osteomac may affect bone remodeling and may play an important role in bone cell network.

Inelastic Seismic Response of Asymmetric-Plan Self-Centering Energy Dissipative Braced Frames (비정형 셀프센터링 가새골조의 비탄성 지진응답)

  • Kim, Jin-Koo;Christopoulos, C.;Choi, Hyun-Hoon
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.35-44
    • /
    • 2008
  • A self-centering energy-dissipative(SCED) bracing system has recently been developed as a new seismic force resistant bracing system. The advantage of the SCED brace system is that, unlike other comparable advanced bracing systems that dissipate energy such as the buckling restrained brace(BRB) system, it has a self-centering capability that reduces or eliminates residual building deformations after major seismic events. In order to investigate the effects of torsion on the SCED brace and BRB systems, nonlinear time history analyses were used to compare the responses of 3D model structures with three different amounts of frame eccentricity. The results of the analysis showed that the interstory drifts of SCED braced frames are more uniform than those of BRB frames, without regard to irregularity. The residual drift and residual rotation responses tended to decrease as irregularity increased. For medium-rise structures, the drift concentration factors(DCFs) for SCED systems were lower than those for BRB frames. This means that SCED-braced frames deform in a more uniform manner with respect to building height. The effect of the torsional irregularity on the magnitude of the DCFs was small.

The Buckling Characteristics of Single-Layer Lamella Domes according to Support Position under Construction (단층라멜라 돔의 시공 중 서포트 위치에 따른 좌굴특성)

  • Kim, Cheol-Hwan;Suk, Chang-Mok;Jung, Hwan-Mok
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.4
    • /
    • pp.67-74
    • /
    • 2010
  • Single layer latticed domes which have a mechanics property, a functional property, a aesthetic property and so on, occupies one part of long span space structures and after this, the using parts will be extended. The frame network pattern of single-layer latticed domes can be infinitely taken into account. The typical network patterns are triangular, square, hexagon, lamella and rib etc. It would take long time and cost too much to erect large roof structures with traditional erection techniques due to require of large number of temporary bracing and supports. The erection of large roof structures requires special techniques. As one of these special techniques is the Step-Up election method that utilizes jack-up supports and this will extremely saves time and cost to erect large roof structures. The objective of this study is to analysis the buckling characteristics of single-layer lamella domes according to the support number and position. From the result of this study, we obtained the fundamental data for the structural engineers who design the temporary support of large roof structures.

  • PDF

Design of Flat Plate Systems Using the Modified Equivalent Frame Method (수정된 등가골조법을 이용한 플랫플레이트 시스템의 설계)

  • Park, Young-Mi;Oh, Seung-Yong;Han, Sang-Whan
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.1
    • /
    • pp.35-41
    • /
    • 2008
  • In general, flat plate systems have been used as a gravity load resisting system (GLRS) in building. Thus, this system should be constructed with lateral force resisting system (LFRS) such as shear walls and brace frames. GLRS should retain the ability to undergo the lateral drift associated with the LFRS without loss of gravity load carrying capacity. And flat plate system can be designed LFRS as ordinary moment frame with the special details. Thus, flat plate system designed as GLRS or LFRS should be considered internal forces (e.g., unbalanced moments) and lateral deformation generated in vicinity of slab joints render the system more susceptible to punching shear. ACI 318 (2005) allows the direct design method, equivalent frame method under gravity loads and allows the finite-element models, effective beam width models, and equivalent frame models under lateral loads. These analysis methods can produce widely different result, and each has advantage and disadvantages. Thus, it is sometimes difficult for a designer to select an appropriate analysis method and interpret the results for design purposes. This study is to help designer selecting analysis method for flat plate system and to verify practicality of the modified equivalent frame method under lateral loads. This study compared internal force and drift obtained from frame methods with those obtained from finite element method under gravity and lateral loads. For this purposes, 7 story building is considered. Also, the accuracy of these models is verified by comparing analysis results using frame methods with published experimental results of NRC slab.

Vibration Control of Mega Frame Structures using a Semi-active Tuned Mass Damper (준능동 TMD를 이용한 메가골조구조물의 진동제어)

  • Kim, Hyun-Su;Lee, Dong-Guen
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.11 no.2 s.54
    • /
    • pp.57-68
    • /
    • 2007
  • The mega frame system is becoming popular for the design and construction of skyscrapers because this system exhibits structural efficiency by allowing high rigidity of the structure while minimizing the amount of structural materials to be used. Since the mega frame system is usually adopted for super high-rise buildings, the comfort of occupants may be main concerns in the practical application of this system. For the enhancement of the serviceability of mega frame structures, a semi-active tuned mass damper (STMD) is developed in this study. To this end, a Magnetorheological (MR) damper is employed replacing passive damper as a semi-active damper to improve the control effect of a conventional TMD. Since a conventional finite element model of mega frame structures has significant numbers of DOFs, numerical simulation for investigation of control performances of a STMD is impossible by using the full-order model. Therefore, a reduced-order system using minimal DOFs, which can accurately represent the dynamic behavior of a mega frame structure, is proposed in this study through the matrix condensation technique To improve the efficiency of the matrix condensation technique, multi-level matrix condensation technique is proposed using the structural characteristics of mega frame structures. The efficiency and accuracy of the reduced-order control proposed in this study and the control performance of a STMD were verified using example structures.

The Structural Performance of PSC Frame System with GerberCs beam (게르버 보 형식의 PSC 골조시스템의 구조성능)

  • Kim, Sang-Sik;Choi, Kwang-Ho;Lee, Jong-Gyu;Song, Hun
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.341-346
    • /
    • 2002
  • 이 연구는 게르버 보 형식의 포스트텐션 PC 골조 구조 시스템의 실용화를 위해 골조 전체의 구조 성능 시험을 수행하며, 여기서 보-기둥 접합부 및 내민 보-단순 보 접합부의 구조 성능과 골조의 안전성을 확인한다. 시험은 400 mm$\times$800 mm 단면의 경간 3 m 보와 500 mm$\times$600 mm 단면을 갖는 높이 3 m 기둥의 실물 크기 시험체를 제작하여, 기둥에 80 톤의 축 하중을 준 상태에서 단순 보 중앙에 하중을 가력하여 기둥-보 접합부와 단순 보-내민 보 단면 축소 연결부의 구조성능을 파악한다. 시험 결과, 보 - 기둥 접합부는 예상 설계 하중 40톤 이상에서도 강 접합에 가깝게 거동하였고, 단순 보- 내민 보의 단면 축소 연결부는 경사철근의 사용으로 초기 균열 및 균열 확산에 대한 억제 효과가 있었으며, 예상 설계 전단력 40톤에서 안전하다는 것이 확인되었다.

  • PDF

A Schematic Estimation Model for Structure Costs of High-rise Buildings based on Vertical and Horizontal Elements (고층건물 수직·수평 요소기반 골조공사 개산견적 모델)

  • Nam, Dong-Hee;Park, Hyung-Jin;Koo, Kyo-Jin
    • Korean Journal of Construction Engineering and Management
    • /
    • v.15 no.1
    • /
    • pp.3-10
    • /
    • 2014
  • High-rise buildings need thorough cost management because of large size and high risk. Cost management makes a budget by establishing and analyzing detail element at planning phase, needs cost control as each design phase, then reflected to next design. This research develops a schematic estimation model based on vertical and horizontal elements at design phase for structure cost of high-rise buildings to reduce error range and use data as design management. Usability of the model is confirmed by case study. The estimation model is expected to contribute to making the cost model more effective and satisfactory to concerned in construction or budget department and manage keeping track of the cost.

Inelastic Behavior and Seismic Retrofit of Inverted V Braced Steel Frames (역V형 철골 가새골조의 비탄성거동 및 내진성능향상 방안에 관한 연구)

  • Kim, Nam Hoon;Lee, Cheol Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.571-578
    • /
    • 2003
  • An effective seismic retrofit scheme for inverted V braced (or chevron type) steel frames was proposed by studying the redistribution of forces in the post-buckling range. The steel frames with chevron bracing are highly prone to soft story response once the compression brace buckles under earthquake loading. This paper shows that the seismic performance of such frames could be significantly improved by supplying tie bars to redistribute the inelastic deformation demand over the height of the building. A practical design method of the retrofit tie bars was also proposed by considering the sequence of buckling occurrence.