• 제목/요약/키워드: 골절의 안정성

검색결과 70건 처리시간 0.032초

Dual Plate Fixation for Displaced Transverse Fracture of the Lower Sacrum (전위된 하부 천골 횡골절에 대한 이중 금속판을 이용한 내고정술)

  • Choi, Dong-Hyuk;Park, Ji-Hun;Shim, Seong-Woo;Choi, Yong-Soo
    • Journal of the Korean Orthopaedic Association
    • /
    • 제55권2호
    • /
    • pp.178-182
    • /
    • 2020
  • Isolated fractures of lower sacrum are commonly treated conservatively in most cases because of low energy damage and stable fracture. However, surgical treatment is required in displaced unstable fracture. But the surgical technique is not established and even case reports are not common. We reported a case of displaced transverse fracture of the lower sacrum that was treated with an open reduction and dual plate fixation.

The Operative Treatment of Scapular Glenoid Fracture (견갑골 관절와 골절의 수술적 치료)

  • Kang, Ho-Jung;Jung, Sung-Hoon;Jung, Min;Hahn, Soo-Bong;Kim, Sung-Jae;Kim, Jong-Min
    • Clinics in Shoulder and Elbow
    • /
    • 제10권2호
    • /
    • pp.212-219
    • /
    • 2007
  • Purpose: To determine the causes of the surgical treatment results in glenoid fracture by a retrospective analysis. Materials and methods: From March 1999 to February 2004, 9 patients who underwent an open reduction due to a glenoid fracture were reviewed. The modified Ideberg classification was used. There were 1, 3, 2, 1 and 2 cases of modified Ideberg type I, II, III, V, and VI, respectively. The internal fixators were a reconstruction plate, a small plate, a one-third tubular plate, a small screw, and a cannulated screw in 6, 1, 3, 3 and 1 case, respectively. The constant score and Adam's functional assessment method were used to evaluate the postoperative shoulder function. Results: The average time for fracture union was 7 weeks. The functional assessment was excellent in 4 cases, good in 3 cases, and fair in 2 cases. There were two complications related to surgery; articular screw encroachment, and inferior glenoid bone resorption without instability. Conclusion: A glenoid fracture with glenohumeral instability or displaced that was treated by open surgery showed good clinical results. Moreover, the more comminuted fracture had a lower functional score.

Arthroscopic Reduction and Fixation of an Anterior Cruciate Ligament Avulsion Fracture From the Tibial Eminence Using Bioabsorbable Pins - Technical Note - (생흡수성 핀을 이용한 소아 경골 과간부 견열 골절의 관절경적 정복 및 고정 방법 - 수술 술기 -)

  • Lee, Su-Chan;Yang, Il-Soon;Seo, Hee-Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • 제13권2호
    • /
    • pp.183-187
    • /
    • 2009
  • Purpose: We describe a new and simple technique for arthroscopic fixation of tibial intercondylar eminence avulsion fracture using bioabsorbable pins in skeletally immature patients. Operative Technique: Diagnostic knee arthroscopy is performed using anterolateral and anteromedial portals. Fracture debris and blood clot are debrided to expose the injured site well. The fragment is reduced with the probe and fixed temporarily with a 1.1-mm diameter K-wire that is inserted percutaneously from the anterosuperior aspect of the knee joint. The drill guide is introduced into the joint and the fragment is secured by bioabsorbable, poly-p-dioxanone 1.3-mm pins inserted from different angles. The pins are 40 mm in length. The knee is placed in a long leg cast in extension for 4 weeks to assure that full extension is obtained. Conclusion: Arthroscopic fixation of an tibial intercondylar eminence avulsion fracture using bioabsorbable pins is not a technically demanding, suitable method that ensures fracture healing and restores the stability of the joint.

  • PDF

Application of Hinged Transarticular External Skeletal Fixator (HTAESF) for Proximal Tibial Physeal Fracture in a Dog (개의 근위 경골 성장판 골절에서 경첩 관절경유 외고정의 적용)

  • Kim, Kwan;Heo, Su-Young;Lee, Hae-Beom
    • Journal of Veterinary Clinics
    • /
    • 제29권6호
    • /
    • pp.502-505
    • /
    • 2012
  • An 8-month-old, 3.5 kg intact female Toy Poodle was presented for non-weight-bearing lameness on left hindlimb. In radiological testing, left proximal tibal type II Salter-Harris physeal fracture and fibular fracture were seen. Following open reduction, the fracture was stabilized with cross-pins, tension band wires, and a hinged transarticular external skeletal fixator (HTAESF). The range of the HTAESF was increased to $25^{\circ}$ at 7 days postsurgery and to $70^{\circ}$ at 14 days post-surgery. The HTAESF was removed 3 weeks after surgery. At 6 weeks post-surgery, the fracture was successfully healed with no complications and the patient recovered a normal gait. Seven months post-surgery, the patient had a normal gait and a normal stifle joint range of motion compared to the contralateral normal limb. This is a case in which the combined use of cross-pins, tension band wires, and HTAESF was successful for treatment of a proximal tibial physeal fracture in a dog. It is thought that these methods are beneficial for stability of fracture site and recover of joint's normal range of motion through early joint movement.

Operative treatment for Proximal Humeral Fracture (상완골 근위부 골절의 수술적 요법)

  • Park Jin-Young;Park Hee-Gon
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • 제2권2호
    • /
    • pp.168-175
    • /
    • 2003
  • Fracture about proximal humerus may be classified as the articular segment or the anatomical neck, the greater tuberosity, the lesser tuberosity, and the shaft or surgical neck. Now, usually used, Neer's classification is based on the number of segments displaced, over 1cm of displaced or more than 45 degrees of angulation , rather than the number of fracture line . Absolute indication of a operative treatment a open fracture, the fracture with vascular injury or nerve injury , and unreductable fracture-dislocation . Inversely, the case that are severe osteoporosis, and eldly patient who can't be operated by strong internal fixation is better than arthroplasty used by primary prosthetic replacement and early rehabilitation program than open reduction and internal fixation. The operator make a decision for the patient who should be taken the open reduction and internal fixation, because it's different that anatomical morphology, bone density, condition of patient. The operator decide operation procedure. For example, percutaneous pinning, open reduction, plate & screws, wire tension bands combined with some intramedullary device are operation procedure that operator can decide . The poor health condition for other health problem, fracture with unstable vital sign and severe osteoporosis , are the relative contraindication. The stable fracture without dislocation is not the operative indication . The radiologic film of the prokimal humerus before the operation can not predict for fracture evaluation. It's necessary to good radiologic film for evaluation of fracture form. The trauma serise is better than the other radiologic film for evaluation. The accessary radiologic exam is able to help for evaluation of bone fragment and anatomy. The CT can be helpful in evaluating these injury, especially if the extract fracture type cannot be determined from plain roenterogram of the proximal humerus, bone of humerus head. If the dislocation is severe anatomically , we could consider to do three dimentional remodelling. The MRI doing for observing of bony morphology before the operation is not better than CT If we were suspicious of vascular injury, we could consider the angiography.

  • PDF

Internal Fixation of Proximal Humerus Fracture with Polyaxial Angular Stable Locking Compression Plate in Patients Older Than 65 Years (65세 이상의 상완골 근위부 골절 환자에서 다축 각안정 잠김 압박 금속판을 이용한 내고정술)

  • Lee, Ki-Won;Choi, Young-Joon;Ahn, Hyung-Sun;Kim, Chung-Hwan;Hwang, Jae-Kwang;Kang, Jeong-Ho;Choo, Han-Ho;Park, Jun-Seok;Kim, Tae-Kyung
    • Clinics in Shoulder and Elbow
    • /
    • 제15권1호
    • /
    • pp.25-31
    • /
    • 2012
  • Purpose: The clinical and radiographic outcomes of the internal fixation, which were executed on patients over the age of 65 with proximal humerus fracture by using a polyaxial angular stable locking compression plate (Non-Contact-Bridging proximal humerus plate, Zimmer, Switzerland, NCB), were evaluated. Materials and Methods: Thirty two patients over the age of 65 among the proximal humerus fracture treated with NCB plate, between August 2007 and January 2011, were chosen as the subjects. The average age of patients was 71 years, and the average postoperative follow-up period was 11.5 months. The fractures included 14 two-part and 18 three-part fractures. The clinical results were evaluated, using the visual analog scale (VAS) score and the Constant score. The radiological results were evaluated by time to union and Paavolainen method, which measures the neck shaft angle. Results: At the last follow-up examination, the mean VAS score was 3 points and the mean Constant score was 64.5 points, with bone union achieved after the average of 16.2 weeks following the surgery in all the cases. The mean neck shaft angle was 125.9 and 24 cases had good results, while 8 cases had fair results by Paavolainen method, at the last follow-up. There were 1 case of delayed union and cerclage wire failure, and 3 cases of subacromial impingement. There were no complications, such as loss of reduction, nonunion, screw loosening, or avascular necrosis of the humeral head. Conclusion: Internal fixation, using a NCB plate, was considered to be an effective surgical method in treating proximal humerus fracture in the elderly patients, on whom the fixation of the fracture and maintenance of reduction are difficult.

Internal Fixation of Proximal Humerus Fracture with Locking Compression Plate (잠김 압박 금속판을 이용한 근위 상완골 골절의 내고정술)

  • Park, Chul-Hyun;Park, Sung-Hyuk;Seo, Jae-Sung
    • Clinics in Shoulder and Elbow
    • /
    • 제12권1호
    • /
    • pp.44-52
    • /
    • 2009
  • Purpose: We assessed the radiographic and clinical results of one surgeon's experience treating proximal humerus fractures with a locked proximal humeral plate. Materials and Methods: Twenty patients with unstable proximal humerus fractures were treated with a locking compression plate between February 2005 and September 2007. The average age of the patients was 60.6 years, and the average postoperative follow-up period was 22.3 months. The clinical results were evaluated using the Constant and DASH scores. The radiologic results were evaluated by the Paavolainen method, which measures the neck shaft angle and humeral head height. Results: At the last follow-up examination, the mean Constant score was 75.3 and 15 cases (75%) had excellent or good results; the mean DASH score was 16.4. The mean neck shaft angle was $137.1^{\circ}$, and 19 cases (95%) had good results by the Paavolainen method. There was one delayed union, malunion, and screw loosening. Conclusion: The patients treated with a locking compression plate had relatively good clinical and radiologic results, and a low complication rate. Moreover, the patients could exercise earlier due to good reduction and initial stability. Treatment of unstable proximal humerus fractures with a locking compression plate is a reliable method.

Occlusal rehabilitation of post-traumatic malocclusion patient after reduction of panfacial fracture, using selective occlusal adjustment and implant prostheses on centric relation: a case report (다발성 안면 골절의 정복 후 발생한 부정교합 상태의 환자를 중심위에서 선택적 교합 조정 및 임플란트 보철수복으로 교합관계를 회복시킨 증례)

  • Dae-Kyun Kim;So-Young Park;Jung-Jin Lee;Yeon-Hee Park;Kyoung-A Kim;Jae-Min Seo
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • 제39권4호
    • /
    • pp.204-213
    • /
    • 2023
  • Invasive or non-invasive reduction of fractures could be conducted as treatments of traumatic maxillofacial bone fractures. But when suboptimal reduction or malunion of maxillofacial bone fracture occurs, malocclusion could occur as a result of the lost relationship of the mandible and midface. This malocclusion is called post-traumatic malocclusion and orthognathic surgery, orthodontic treatment, selective grinding and prosthetic reconstruction are suggested as treatments for post-traumatic malocclusion after securement of stable TMJ. Stable TMJ is essential for occlusal rehabilitation to prevent occlusal change and relapse of malocclusion. Centric relation and adapted centric posture are suggested as start points of occlusal rehabilitation because they are most stable TMJ position. This case report presents a case in which post-traumatic malocclusion occurred after reduction of panfacial fracture. To rehabilitate full mouth occlusion, selective grinding and prosthetic reconstruction of implant supported fixed prostheses were conducted in centric relation and showed satisfying results in functional and occlusal aspects.

Complications after Trauma Around the Elbow Joint (주관절 주위 외상후 합병증)

  • Jeon, In-Ho;Kim, Ju-Eun;Kim, Poong-Taek
    • Clinics in Shoulder and Elbow
    • /
    • 제12권2호
    • /
    • pp.264-270
    • /
    • 2009
  • Purpose: The elbow joint is one of the most stable joints. Dislocation and fracture can occur in elbow joint most commonly next to shoulder joint. Various injuries can occur according to generated mechanism, age of patient and impact. Despite proper treatment, various complications can occur. Materials and Methods: We describe etiology and treatment of these complications after elbow trauma such as stiffness, instability and heterotopic ossification. Results and Conclusion: Malunion, nonunion and traumatic arthritis are addressed as a possible complication after fracture around elbow joint.

Design and Implementation of A Medical Image Guided System for Vertebroplasty (척추성형술을 위한 의료 영상 시스템의 설계 및 개발)

  • Tack, Gye-Rae;Lee, Sang-Bum;Lee, Sung-Jae
    • The KIPS Transactions:PartB
    • /
    • 제10B권5호
    • /
    • pp.503-508
    • /
    • 2003
  • Since surgical treatment of the spine should overcome neurological compromises, the operative procedures need to be carefully planned and carried out with high degree of precision. Percutaneous vertebroplasty is a surgical procedure that was introduced for the treatment of compression fracture of the vertebrae. This procedure includes puncturing vertebrae and filling with polymethylmethacrylate (PMMA). Recent studies have shown that the procedure could provide structural reinforcement for the osteoporotic vertebrae while being minimally invasive and safe with immediate relief of pain. However, failures of treatment due to excessive PMMA volume injection have been reported as one of complications in vertebroplasty. It is believed that the control of PMMA volume is one of the most critical factors that can reduce the incidence of complications. Therefore, clinical success of vertebroplasty can be dependent on the volume of PMMA injection for a given patient. In this study, the optimal volume of PMMA injection for vertebroplasty was predicted based on the image analysis of a given patient.