• Title/Summary/Keyword: 골유합술

Search Result 6, Processing Time 0.021 seconds

Surgical Results of Patients with Isthmic Spondylolisthesis with Transpedicular Screw Fixation and Posterior Lumbar Interbody Fusion Using Posterior Movable Segment (협부형 척추전방전위증에 대한 후방가동관절 이용한 골유합술 및 척추경나사못 고정술의 수술적 결과)

  • Kim, Chan;Lee, Seung Myung;Shin, Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup1
    • /
    • pp.108-114
    • /
    • 2001
  • Objective : Posterior lumbar interbody fusion(PLIF) provides the favorable outcome to degenerative lumbar disease, especially isthmic spondylolisthesis. To determine the long-term effect of PLIF using psterior movable segment, we analysed the results of follow-up radiologic changes and surgical outcome retrospectively Patients and Method : During the past 11 years(1989. 1.-1999. 9.), 148 patients with symptomatic lumbar spondylolisthesis were managed at our department and the clinical wants were throughly recieved and final outcome is determined at last follow up. PLIF using antogenous bone(posterior movable segment, iliac bone and rib) were performed in 106 case. Results : After an average follow-up period of 33 months(range ; 15-58 months), the results were excellent in 66 cases, good in 37 cases, fair in 2 cases and poor in 1 cases. And the satisfactory results were 103 cases(98.2%) in PLIF,. Conclusion : In conclusion, patients who underwent PLIF with autologous bone graft had good clinical and radiological outcomes without significant neurological complications.

  • PDF

Analysis about Associated Factors of Nonunion Following Tibiotalar Arthrodesis (경거골유합술 후 발생하는 불유합과 관련된 인자에 대한 분석)

  • Lee, Jun Young;Kim, Bo Sun;Lee, Jung Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.21 no.3
    • /
    • pp.98-103
    • /
    • 2017
  • Purpose: The aim of this study was to analyze the factors related to nonunion in tibiotalar arthrodesis. Materials and Methods: Eighty cases of ankle arthritis treated with tibiotalar arthrodesis in our hospital from November 2008 to November 2015 with more than one year follow up were analyzed. Simple anteroposterior and lateral radiographs after 6 and 12 months of surgery were analyzed. Union was defined as more than 50% connection of the trabecular bone at the ankle joint surface in the anteroposterior and lateral radiographs. The nonunion group was defined as no signs of union with persistent pain 9 months after surgery. The surgical approach, type of used screw, preoperative and postoperative ankle alignment, body mass index (BMI), bone mineral density, and patients' prior history were compared between the two groups. Results: There were 69 union cases and 11 nonunion cases. In the patient factors, the gender and BMI was related to nonunion (p<0.05). The mean preoperative and postoperative ankle alignment in the nonunion group was $9.93^{\circ}{\pm}6.92^{\circ}$ and $5.43^{\circ}{\pm}3.35^{\circ}$ respectively, and $9.80^{\circ}{\pm}7.55^{\circ}$ and $5.63^{\circ}{\pm}3.45^{\circ}$ in the union group, respectively; the difference was not statistically significant (p>0.05). In the technical factors, the transfibular approach showed a better relationship but the association was not significant (p<0.05). In 40 cases of the transfibular approach, 12 cases used cancellous screws, and 4 cases showed nonunion due to screw breakage. Conclusion: Technical factors, such as the surgical approach and the type of screw used can be a risk factor in nonunion. In addition, patients' factors, such as gender and BMI, must be considered to reduce the nonunion rate.

Posterior C1-2 Transarticular Screw Fixation without C1-2 Sublaminar Wiring in Atlantoaxial Instability (제 1, 2 경추간 판하철사고정술 없는 후방 경관절 나사못 고정술 및 골유합술)

  • Shin, Yong Hwan;Hwang, Jeong Hyun;Sung, Joo Kyung;Hwang, Sung Kyu;Hamm, In Suk;Park, Yeun Mook;Kim, Seung Lae
    • Journal of Korean Neurosurgical Society
    • /
    • v.29 no.11
    • /
    • pp.1469-1475
    • /
    • 2000
  • Objective : The goal of this study was to evaluate the clinical outcome of the posterior C1-2 transarticular screw fixation without C1-2 sublaminar wiring in atlantoaxial instability. Methods : Between Apr. 1995 and Feb. 2000, we used this technique in treat randomly selected 17 patients (11 men, 6 women) who had atlantoaxial instability. The causes of instability were : type II-A odontoid process fracture(10 cases) ; type II-P odontoid process fracture(1 case) ; Os odontoideum(2 cases) ; transverse ligament laxity due to rheumatoid disease(1 case) ; and, transverse ligament injury without bone fracture(3 cases). All cases were operated with posterior C1-2 transarticular screw fixation with 3.5mm cortical screw and interlaminar iliac graft without sublaminar wire fixation. The mean follow-up period was 28 months(5 to 58 months) and the mean age at the time of operation was 41 years(15 to 68 years). All Patients were allowed to ambulate with Philadelphia neck collar on the first post-operation day. Results : Bony fusion was successfully achieved in all cases demonstrated at 3-month follow-up studies. There was no operative mortality or morbidity. Conclusion : The authors conclude that the posterior transarticular screw fixation without C1-2 sublaminar wiring provide adequate stability with high bony union rate in atlantoaxial instability of various causes.

  • PDF

Evaluation of Usefulness and Availability for Orthopedic Surgery using Clavicle Fracture Model Manufactured by Desktop 3D Printer (보급형 3D 프린터로 제작한 쇄골 골절 모델을 이용한 정형외과 수술에 대한 유용성과 활용가능성 평가)

  • Oh, Wang-Kyun
    • Journal of radiological science and technology
    • /
    • v.37 no.3
    • /
    • pp.203-209
    • /
    • 2014
  • Usefulness and clinical availability for surgery efficiency were evaluated by conducting pre-operative planning with a model manufactured by desktop 3D printer by using clavicle CT image. The patient-customized clavicle fracture model was manufactured by desktop 3D printer of FDM wire laminated processing method by converting the CT image into STL file in Open Source DICOM Viewer Osirix. Also, the model of the original shape before damaged was restored and manufactured by Mirror technique based on STL file of not fractured clavicle of the other side by using the symmetry feature of the human body. For the model, the position and size, degree of the fracture was equally printed out. Using the clavicle model directly manufactured with low cost and less time in Department of Radiology is considered to be useful because it can reduce secondary damage during surgery and increase surgery efficiency with Minimal invasive percutaneous plate osteosynthesis(MIPO).

Comparison of Clinical Outcome of Excision versus Osteosynthesis in Type II Accessory Navicular (족부 제2형 부주상골에서 절제술과 골유합술 간의 임상적 결과 비교)

  • Lee, Jong-Seok;Youn, Hyun-Kook;Choi, Woo-Jin;Lee, Jin-Woo
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.2
    • /
    • pp.72-78
    • /
    • 2011
  • Purpose: The purpose of this study is to compare the clinical outcome of excision versus osteosynthesis of type II accessory navicular performed by a single surgeon. Materials and Methods: Cases of 14 feet treated with excision and 13 feet by osteosynthesis for type II accessory navicular of 25 patients from 2002 to 2009 were included in this study. Radiological measurements and American Orthopaedic Foot and Ankle Society (AOFAS) midfoot scale was evaluated. Results: AOFAS midfoot scale of both excision and osteosynthesis groups at last follow-up showed improvement from pre-operation. However, there was no statistical difference in AOFAS midfoot scale and subjective satisfaction between the two groups at last follow-up. In detail of AOFAS midfoot scale, pain and footwear requirements showed statistically favorable results for the excision group, while activity limitation and support showed statistically favorable results for the osteosynthesis group. Subjective recovery time returning to daily activities and starting rehabilitation exercise were 14.6 weeks in the excision group and 13.7 weeks in the osteosynthesis group (p=0.025, Mann-Whitney). Suture anchor loosening was observed in one case in the excision group and non-union in two cases in the osteosynthesis group. Conclusion: Both excision and osteosynthesis are favorable surgical methods, but each method has advantages and possible complications such as suture anchor loosening or non-union. Surgeon's preference, patient's chief complaint, specific needs of patient after the operation and consideration of the size of accessory navicular can be a criteria to consider when selecting a surgical method.

The Treatment of Humerus Shaft Simple Fracture by MIPO Technique (상완골 간부 단순 골절에서 최소 침습적 금속판 골유합술을 이용한 치료)

  • Ko, Sang-Hun;Lee, Sun-Ho;Cho, Bum-Keun
    • Clinics in Shoulder and Elbow
    • /
    • v.16 no.1
    • /
    • pp.27-32
    • /
    • 2013
  • Purpose: The purpose of this study is to evaluate the clinical and radiological outcomes of treatment of humerus shaft simple fracture by minimally invasive percutaneous osteosynthesis (MIPO) technique using locking compression plate (LCP). Materials and Methods: Six patients who were operated for humerus shaft simple fracture from August 2010 to May 2011 were enrolled for this study. We checked the cause of injury and the accompanying injuries and evaluated the operation time, the clinical and radiological period of union, postoperative range of motion of the shoulder and elbow joint, pain, activities in daily living, radiologic alignment, and other complications. Results: The clinical period of bone union was 7.2 weeks on average, and the radiologic period of bone union was 8 weeks on average. Follow-up period was more than 12 months in all cases. The angulation through postoperative alignment was 2.8 degrees in AP view and 2 degrees in lateral view. The postoperative range of motion was 167 degrees in forward flexion, 50 degrees in external rotation, and thoracic vertebra 12 level in internal rotation. The average value of visual analogue scale (VAS) was 1.2 and that of KSS was 91.3. The American Shoulder and Elbow Surgeons' score (ASES) was 26.5 and the UCLA score was 31.5. Conclusion: MIPO technique for the humerus shaft simple fracture showed good functional and radiological outcomes and may be considered as one of the treatment options for humerus shaft simple fracture.