• Title/Summary/Keyword: 곡선 적응

Search Result 124, Processing Time 0.022 seconds

Comparison of using CBCT with CT simulator for radiation dose of treatment planning (CBCT와 Simulation CT를 이용한 치료계획의 선량비교)

  • Cho, jung-keun;Kim, dae-young;Han, tae-jong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2009.05a
    • /
    • pp.1159-1166
    • /
    • 2009
  • The use of cone-beam computed tomography(CBCT) has been proposed for guiding the delivery of radiation therapy. A kilovoltage imaging system capable of radiography, fluoroscopy, and cone-beam computed tomography(CT) has been integrated with a medical linear accelerator. A standard clinical linear accelerator, operating in arc therapy mode, and an amorphous-silicon (a-Si) with an on-board electronic portal imager can be used to treat palliative patient and verify the patient's position prior to treatment. On-board CBCT images are used to generate patient geometric models to assist patient setup. The image data can also, potentially, be used for dose reconstruction in combination with the fluence maps from treatment plan. In this study, the accuracy of Hounsfield Units of CBCT images as well as the accuracy of dose calculations based on CBCT images of a phantom and compared the results with those of using CT simulator images. Phantom and patient studies were carried out to evaluate the achievable accuracy in using CBCT and CT stimulator for dose calculation. Relative electron density as a function of HU was obtained for both planning CT stimulator and CBCT using a Catphan-600 (The Phantom Laboratory, USA) calibration phantom. A clinical treatment planning system was employed for CT stimulator and CBCT based dose calculations and subsequent comparisons. The dosimetric consequence as the result of HU variation in CBCT was evaluated by comparing MU/cCy. The differences were about 2.7% (3-4MU/100cGy) in phantom and 2.5% (1-3MU/100cGy) in patients. The difference in HU values in Catphan was small. However, the magnitude of scatter and artifacts in CBCT images are affected by limitation of detector's FOV and patient's involuntary motions. CBCT images included scatters and artifacts due to In addition to guide the patient setup process, CBCT data acquired prior to the treatment be used to recalculate or verify the treatment plan based on the patient anatomy of the treatment area. And the CBCT has potential to become a very useful tool for on-line ART.)

  • PDF

Study on Strain Measurement of Agricultural Machine Elements Using Microcomputer (Microcomputer를 이용(利用)한 농업기계요소(農業機械要素)의 Strain 측정(測定)에 관(關)한 연구(硏究))

  • Kim, Kee Dae;Kim, Tae Kyun;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.8 no.1
    • /
    • pp.90-96
    • /
    • 1981
  • To design more efficient agricultural machinery, the accurately measuring system among many other factors is essential. A light-beam oscillographic recorder is generally used in measuring dynamic strain but it is not compatible with the extremely high speed measuring system such as 1,000 m/s, also is susceptable to damage due to vibration while using the system in field. The recorder used light sensitive paper for strip chart recording. The reading and analysis of data from the strip charts is very cumbersome, errorneous and time consuming. A microcomputer was interfaced with A/D converter, microcomputer program was developed for measuring, system calibration was done and the strain generated from a cantilever beam vibrator was measured. The results are summarized as follows. 1. Microcomputer program was developed to perform strain measuring of agricultural machine elements and could be controled freely the measuring intervals, no. of channels and no. of data. The maximum measuring speed was $62{\mu}s$. 2. Calibration the system was performed with triangle wave generated from a function generator and checked by an oscilloscope. The sampled data were processed using HP 3000 minicomputer of Chungnam National University computer center the graphical results were triangle same as input wave and so the system have been out of phase distorsion and amplitude distorsion. 3. The strain generated from a cantilever beam vibrator which has free vibration period of 0.019 second were measured by the system controlled to have l.0 ms of time interval and its computer output showing vibration curve which is well filted to theoretical value. 4. Using microcomputer on measuring the strain of agricultural machine elements could not only save analyzing time and recording papers but also get excellent adaptation to field experiment, especially in measurement requiring high speed and good precision.

  • PDF

Guideline in the Management of Antenatally Diagnosed Unilateral Hydronephrosis (산전 초음파로 발견된 수신증의 치료 방침)

  • Hahn Hye-Won;Jun Nu-Lee;Kim Kun-Seok;Moon Dae-Hyuk;Yoon Chong-Hyun;Park Young-Seo
    • Childhood Kidney Diseases
    • /
    • v.7 no.1
    • /
    • pp.60-66
    • /
    • 2003
  • Purpose : Neonatal hydronephrosis has been detected with increasing frequency with the widespread use of prenatal ultrasonography, but the consensus about its postnatal management has not yet been reached, especially about surgical intervention. We attempted to determine the guideline of follow-up study and surgical intervention of hydronephrosis by analyzing clinical outcomes of neonates with hydronephrosis. Materials and Methods : Between 1994 and 2000, 128 hydronephrotic kidneys were postnatally confirmed. Cases associated with other urologic anomalies were excluded and 90 unilateral hydronephrotic kidneys with a minimum follow-up of 12 months were enrolled in this study. We classified the patients into 6 groups according to the anterior posterior pelvic diameter(APPD) at initial ultrasonography(USG) within 1 month after birth. Renal USG and $Tc^{99m}-mercaptoacetyl$ triglycerine(MAG3) scan were done according to a set protocol, and pyeloplasty was performed when indicated according to our protocol. Results : Most cases whose APPD were below 10 mm improved or resolved. Only few cases with APPD above 20 mm showed spontaneous improvement and most(88%) had undergone operation. Those with initial APPD within 10-19 mm showed variable outcomes. When the risk factors for irreversible renal functional deterioration were analyzed, the age at pyeloplasty and pre-operative functional deficit were significant. Conclusion : We concluded that in infants with initial APPD below 10 mm, consideration of surgery is not needed, and in those with initial APPD above 20 mm, early operation is recommended. Our set protocol based on initial USG is useful, but the cut-off value of relative renal function(RRF) for operation might be increased to 40% to improve post operative RRF.

  • PDF

Failure Pattern of Pineal and Ectopic Pineal Germ Cell Tumor after Gamma Knife Radiosurgery (송과선 및 이소성 송과선 생식세포종의 감마 나이프 수술 후 재발 양상)

  • Cho, Heung-Lae;Sohn, Seung-Chang
    • Radiation Oncology Journal
    • /
    • v.18 no.2
    • /
    • pp.92-100
    • /
    • 2000
  • Purpose :This study was performed to determine the optimal treatment velum of Patients treating with radiation therapy for intracranial germ cell tumor. Materials and Methods : From 1993 to 1998, 19 patients with intracranial germ cell tumors treated by gamma knife radiosurgery were analyzed. The location of tumor was as follows; 9 cases on pineal region, 1 case on suprasellar region, and 9 cases of multiple lesion. 7 patients were pathologically verified; 5 cases of germ cell tumor and 2 cases of non germinomatous germ cell tumor. Tumor volume was ranged from 2.4 cm$^{3}$ to 74 cm$^{3}$. Irradiation dose was 10 Gy to 20 Gy with 50% isodose curve. Follow up period was 10 months to 54 months. Results : Recurrences were observed in 14 cases among 19 (74%) patients. Complete remission and partial remission were achieved in 2 (11%) and 10 (53%) respectively. No response was observed in 7 (36%). 2 cases were recurred within original tumor bed. 6 cases were recurred beyond but contiguous with tumor bed. Ventricular relapses separated from pretreatment tumor bed were 3. Spinal recurrences were 4. Among 8 recurred cases of which tumor volume is smaller than 20 cm$^{3}$, 2 were recurred within original tumor bed, 4 were recurred beyond but contiguous with tumor bed, and 1 spinal recurrence. Meanwhile, 6 cases of which tumor volume larger than 20 cm3, 1 case was recurred beyond but contiguous with tumorbed, 2 ventricular recurrences separated with original tumor bed, and 3 spinal recurrences. 5 cases which did not show any recurrence sign showed characteristics of single lesion, tumor volume smaller than 20 cm$^{3}$ and normal tumor marker. All of 4 cases of spinal recurrences happened in the case having ventricular invasion or lesion. Among 9 cases having multiple lesion, only 3 cases recurred within original tumor bed or around tumor bed, the other 6 cases recurred separated from pretreatment tumor bed. Conclusion : Gamma knife radiosurgery is not recommended for the treatment of intracranial germ cell tumor. It is because of small treatment volume and inadequate radiation dose that are characteristics of gamma knife radiosurgery. Tumor volume, ventricular invasion or ventricular lesion in multiple lesion are important factors to be considered for the wide field radiation therapy Tumor volume smaller than 20 cm$^{3}$, single lesion, no ventricular lesion or invasion, and normal tumor marker are ideal indications for small involved field radiation therapy. Prophylactic spinal irradiation seems to be necessary when there is ventricular lesion, ventricular invasion, and multiple lesions. When the tumor volume is larger than 20 cm$^{3}$, multiple lesions, abnormal tumor marker, and whole ventricular irradiation or partial brain irradiation would be possible and neoadjuvant chemotherapy would be most beneficial in these group.

  • PDF